Quantitative assessment of rotator cuff muscle elasticity: Reliability and feasibility of shear wave elastography

Taku Hatta, Hugo Giambini, Kosuke Uehara, Seiji Okamoto, Shigao D Chen, John W. Sperling, Eiji Itoi, Kai Nan An

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.

Original languageEnglish (US)
Pages (from-to)3853-3858
Number of pages6
JournalJournal of Biomechanics
Volume48
Issue number14
DOIs
StatePublished - Nov 5 2015

Fingerprint

Elasticity Imaging Techniques
Rotator Cuff
Shear waves
Elasticity
Muscle
Muscles
Subcutaneous Fat
Oils and fats
Skin
Tissue
Superficial Back Muscles
Pathology
Transducers
Tears
Ultrasonography
Ultrasonics
Stiffness

Keywords

  • Feasibility
  • Muscle elasticity
  • Reliability
  • Shear wave elastography
  • Supraspinatus muscle

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Rehabilitation
  • Biophysics
  • Biomedical Engineering

Cite this

Quantitative assessment of rotator cuff muscle elasticity : Reliability and feasibility of shear wave elastography. / Hatta, Taku; Giambini, Hugo; Uehara, Kosuke; Okamoto, Seiji; Chen, Shigao D; Sperling, John W.; Itoi, Eiji; An, Kai Nan.

In: Journal of Biomechanics, Vol. 48, No. 14, 05.11.2015, p. 3853-3858.

Research output: Contribution to journalArticle

Hatta, Taku ; Giambini, Hugo ; Uehara, Kosuke ; Okamoto, Seiji ; Chen, Shigao D ; Sperling, John W. ; Itoi, Eiji ; An, Kai Nan. / Quantitative assessment of rotator cuff muscle elasticity : Reliability and feasibility of shear wave elastography. In: Journal of Biomechanics. 2015 ; Vol. 48, No. 14. pp. 3853-3858.
@article{b4cdcbaf44f34af18ebf607911ea5ff4,
title = "Quantitative assessment of rotator cuff muscle elasticity: Reliability and feasibility of shear wave elastography",
abstract = "Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.",
keywords = "Feasibility, Muscle elasticity, Reliability, Shear wave elastography, Supraspinatus muscle",
author = "Taku Hatta and Hugo Giambini and Kosuke Uehara and Seiji Okamoto and Chen, {Shigao D} and Sperling, {John W.} and Eiji Itoi and An, {Kai Nan}",
year = "2015",
month = "11",
day = "5",
doi = "10.1016/j.jbiomech.2015.09.038",
language = "English (US)",
volume = "48",
pages = "3853--3858",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "14",

}

TY - JOUR

T1 - Quantitative assessment of rotator cuff muscle elasticity

T2 - Reliability and feasibility of shear wave elastography

AU - Hatta, Taku

AU - Giambini, Hugo

AU - Uehara, Kosuke

AU - Okamoto, Seiji

AU - Chen, Shigao D

AU - Sperling, John W.

AU - Itoi, Eiji

AU - An, Kai Nan

PY - 2015/11/5

Y1 - 2015/11/5

N2 - Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.

AB - Ultrasound imaging has been used to evaluate various shoulder pathologies, whereas, quantification of the rotator cuff muscle stiffness using shear wave elastography (SWE) has not been verified. The purpose of this study was to investigate the reliability and feasibility of SWE measurements for the quantification of supraspinatus (SSP) muscle elasticity. Thirty cadaveric shoulders (18 intact and 12 with torn rotator cuff) were used. Intra- and inter-observer reliability was evaluated on an established SWE technique for measuring the SSP muscle elasticity. To assess the effect of overlying soft tissues above the SSP muscle, SWE values were measured with the transducer placed on the skin, on the subcutaneous fat after removing the skin, on the trapezius muscle after removing the subcutaneous fat, and directly on the SSP muscle. In addition, SWE measurements on 4 shoulder positions (0°, 30°, 60°, and 90° abduction) were compared in those with/without rotator cuff tears. Intra- and inter-observer reliability of SWE measurements were excellent for all regions in SSP muscle. Also, removing the overlying soft tissue showed no significant difference on SWE values measured in the SSP muscle. The SSP muscle with 0° abduction showed large SWE values, whereas, shoulders with large-massive tear showed smaller variation throughout the adduction-abduction positions. SWE is a reliable and feasible tool for quantitatively assessing the SSP muscle elasticity. This study also presented SWE measurements on the SSP muscle under various shoulder abduction positions which might help characterize patterns in accordance to the size of rotator cuff tears.

KW - Feasibility

KW - Muscle elasticity

KW - Reliability

KW - Shear wave elastography

KW - Supraspinatus muscle

UR - http://www.scopus.com/inward/record.url?scp=84947059361&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84947059361&partnerID=8YFLogxK

U2 - 10.1016/j.jbiomech.2015.09.038

DO - 10.1016/j.jbiomech.2015.09.038

M3 - Article

C2 - 26472309

AN - SCOPUS:84947059361

VL - 48

SP - 3853

EP - 3858

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 14

ER -