Prostate cryotherapy monitoring using vibroacoustography: Preliminary results of an ex vivo study and technical feasibility

Farid G. Mitri, Brian J. Davis, Azra Alizad, James F Greenleaf, Torrence M. Wilson, Lance A. Mynderse, Mostafa Fatemi

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

The objective of this research is to prospectively evaluate the feasibility of vibroacoustography (VA) imaging in monitoring prostate cryotherapy in an ex vivo model. Baseline scanning of an excised human prostate is accomplished by a VA system apparatus in a tank of degassed water. Alcohol and dry ice mixture are used to freeze two prostate tissue samples. The frozen prostates are subsequently placed within the water tank at 27°C and rescanned. VA images were acquired at prescribed time intervals to characterize the acoustic properties of the partially frozen tissue. The frozen prostate tissue appears in the images as hypoemitting signal. Once the tissue thaws, previously frozen regions show coarser texture than prior to freezing. The margin of the frozen tissue is delineated with a well-defined rim. The thawed cryolesions show a different contrast compared with normal unfrozen prostate. In conclusion, this pilot study shows that VA produces clear images of a frozen prostate at different temperature stages. The frozen tissue appears as a uniform region with well-defined borders that are readily identified. These characteristic images should allow safer and more efficient application of prostatic cryosurgery. These results provide substantial motivation to further investigate VA as a potential modality to monitor prostate cryotherapy intraoperatively.

Original languageEnglish (US)
Pages (from-to)2584-2592
Number of pages9
JournalIEEE Transactions on Biomedical Engineering
Volume55
Issue number11
DOIs
StatePublished - Nov 2008

Fingerprint

Cryotherapy
Tissue
Monitoring
Cryosurgery
Acoustic properties
Water tanks
Freezing
Ice
Alcohols
Textures
Scanning
Imaging techniques

Keywords

  • Cryosurgery
  • Prostate cancer
  • Ultrasound
  • Vibroacoustography (VA)

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Prostate cryotherapy monitoring using vibroacoustography : Preliminary results of an ex vivo study and technical feasibility. / Mitri, Farid G.; Davis, Brian J.; Alizad, Azra; Greenleaf, James F; Wilson, Torrence M.; Mynderse, Lance A.; Fatemi, Mostafa.

In: IEEE Transactions on Biomedical Engineering, Vol. 55, No. 11, 11.2008, p. 2584-2592.

Research output: Contribution to journalArticle

@article{b8b9c13886334b548fc1f338804a74db,
title = "Prostate cryotherapy monitoring using vibroacoustography: Preliminary results of an ex vivo study and technical feasibility",
abstract = "The objective of this research is to prospectively evaluate the feasibility of vibroacoustography (VA) imaging in monitoring prostate cryotherapy in an ex vivo model. Baseline scanning of an excised human prostate is accomplished by a VA system apparatus in a tank of degassed water. Alcohol and dry ice mixture are used to freeze two prostate tissue samples. The frozen prostates are subsequently placed within the water tank at 27°C and rescanned. VA images were acquired at prescribed time intervals to characterize the acoustic properties of the partially frozen tissue. The frozen prostate tissue appears in the images as hypoemitting signal. Once the tissue thaws, previously frozen regions show coarser texture than prior to freezing. The margin of the frozen tissue is delineated with a well-defined rim. The thawed cryolesions show a different contrast compared with normal unfrozen prostate. In conclusion, this pilot study shows that VA produces clear images of a frozen prostate at different temperature stages. The frozen tissue appears as a uniform region with well-defined borders that are readily identified. These characteristic images should allow safer and more efficient application of prostatic cryosurgery. These results provide substantial motivation to further investigate VA as a potential modality to monitor prostate cryotherapy intraoperatively.",
keywords = "Cryosurgery, Prostate cancer, Ultrasound, Vibroacoustography (VA)",
author = "Mitri, {Farid G.} and Davis, {Brian J.} and Azra Alizad and Greenleaf, {James F} and Wilson, {Torrence M.} and Mynderse, {Lance A.} and Mostafa Fatemi",
year = "2008",
month = "11",
doi = "10.1109/TBME.2008.2001284",
language = "English (US)",
volume = "55",
pages = "2584--2592",
journal = "IEEE Transactions on Biomedical Engineering",
issn = "0018-9294",
publisher = "IEEE Computer Society",
number = "11",

}

TY - JOUR

T1 - Prostate cryotherapy monitoring using vibroacoustography

T2 - Preliminary results of an ex vivo study and technical feasibility

AU - Mitri, Farid G.

AU - Davis, Brian J.

AU - Alizad, Azra

AU - Greenleaf, James F

AU - Wilson, Torrence M.

AU - Mynderse, Lance A.

AU - Fatemi, Mostafa

PY - 2008/11

Y1 - 2008/11

N2 - The objective of this research is to prospectively evaluate the feasibility of vibroacoustography (VA) imaging in monitoring prostate cryotherapy in an ex vivo model. Baseline scanning of an excised human prostate is accomplished by a VA system apparatus in a tank of degassed water. Alcohol and dry ice mixture are used to freeze two prostate tissue samples. The frozen prostates are subsequently placed within the water tank at 27°C and rescanned. VA images were acquired at prescribed time intervals to characterize the acoustic properties of the partially frozen tissue. The frozen prostate tissue appears in the images as hypoemitting signal. Once the tissue thaws, previously frozen regions show coarser texture than prior to freezing. The margin of the frozen tissue is delineated with a well-defined rim. The thawed cryolesions show a different contrast compared with normal unfrozen prostate. In conclusion, this pilot study shows that VA produces clear images of a frozen prostate at different temperature stages. The frozen tissue appears as a uniform region with well-defined borders that are readily identified. These characteristic images should allow safer and more efficient application of prostatic cryosurgery. These results provide substantial motivation to further investigate VA as a potential modality to monitor prostate cryotherapy intraoperatively.

AB - The objective of this research is to prospectively evaluate the feasibility of vibroacoustography (VA) imaging in monitoring prostate cryotherapy in an ex vivo model. Baseline scanning of an excised human prostate is accomplished by a VA system apparatus in a tank of degassed water. Alcohol and dry ice mixture are used to freeze two prostate tissue samples. The frozen prostates are subsequently placed within the water tank at 27°C and rescanned. VA images were acquired at prescribed time intervals to characterize the acoustic properties of the partially frozen tissue. The frozen prostate tissue appears in the images as hypoemitting signal. Once the tissue thaws, previously frozen regions show coarser texture than prior to freezing. The margin of the frozen tissue is delineated with a well-defined rim. The thawed cryolesions show a different contrast compared with normal unfrozen prostate. In conclusion, this pilot study shows that VA produces clear images of a frozen prostate at different temperature stages. The frozen tissue appears as a uniform region with well-defined borders that are readily identified. These characteristic images should allow safer and more efficient application of prostatic cryosurgery. These results provide substantial motivation to further investigate VA as a potential modality to monitor prostate cryotherapy intraoperatively.

KW - Cryosurgery

KW - Prostate cancer

KW - Ultrasound

KW - Vibroacoustography (VA)

UR - http://www.scopus.com/inward/record.url?scp=55749102719&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=55749102719&partnerID=8YFLogxK

U2 - 10.1109/TBME.2008.2001284

DO - 10.1109/TBME.2008.2001284

M3 - Article

C2 - 18990628

AN - SCOPUS:55749102719

VL - 55

SP - 2584

EP - 2592

JO - IEEE Transactions on Biomedical Engineering

JF - IEEE Transactions on Biomedical Engineering

SN - 0018-9294

IS - 11

ER -