Prostate brachytherapy seed reconstruction using an adaptive grouping technique

Yi Su, Brian J. Davis, Keith M. Furutani, Michael G. Herman, Richard A. Robb

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Fluoroscopy-based three-dimensional seed localization as a component of intraoperative dosimetry for prostate brachytherapy is an active area of research. A novel adaptive-grouping-based reconstruction approach is developed. This approach can recover overlapped seeds that are not detected from the fluoroscopic images. Two versions of the adaptive-grouping-based reconstruction approach are implemented and compared to an epipolar geometry-based seed reconstruction technique. Simulations based on nine patient datasets are used to validate the algorithms. A total of 2259 reconstructions is performed in which different types of error such as random noise in seed image locations and ambiguities in projection geometry are incorporated. Among those reconstructions, nine of the cases with overlapping seeds and the different types of error are performed. It is demonstrated that the adaptive-grouping- based reconstruction method is more accurate than the epipolar geometry method and allows faster reconstruction. At a random noise level of 0.6 mm, the mean distance error in reconstructed seed locations is approximately 1.0 mm for one of the relevant cases examined in detail. The best adaptive-grouping-based approach successfully recovered overlapped seeds in the majority of simulated cases (89%), with the remainder of cases generating one false positive seed. Phantom validation is also performed, and overlapped seeds are successfully recovered with all 92 seeds correctly localized and reconstructed. The mean distance error between segmented seed images and projected seeds is 0.5 mm in the phantom study.

Original languageEnglish (US)
Pages (from-to)2975-2984
Number of pages10
JournalMedical Physics
Volume34
Issue number7
DOIs
StatePublished - 2007

Fingerprint

Brachytherapy
Prostate
Seeds
Fluoroscopy

Keywords

  • Brachytherapy
  • Fluoroscopy
  • Seed localization

ASJC Scopus subject areas

  • Biophysics

Cite this

Su, Y., Davis, B. J., Furutani, K. M., Herman, M. G., & Robb, R. A. (2007). Prostate brachytherapy seed reconstruction using an adaptive grouping technique. Medical Physics, 34(7), 2975-2984. https://doi.org/10.1118/1.2745936

Prostate brachytherapy seed reconstruction using an adaptive grouping technique. / Su, Yi; Davis, Brian J.; Furutani, Keith M.; Herman, Michael G.; Robb, Richard A.

In: Medical Physics, Vol. 34, No. 7, 2007, p. 2975-2984.

Research output: Contribution to journalArticle

Su, Y, Davis, BJ, Furutani, KM, Herman, MG & Robb, RA 2007, 'Prostate brachytherapy seed reconstruction using an adaptive grouping technique', Medical Physics, vol. 34, no. 7, pp. 2975-2984. https://doi.org/10.1118/1.2745936
Su, Yi ; Davis, Brian J. ; Furutani, Keith M. ; Herman, Michael G. ; Robb, Richard A. / Prostate brachytherapy seed reconstruction using an adaptive grouping technique. In: Medical Physics. 2007 ; Vol. 34, No. 7. pp. 2975-2984.
@article{f7e8dcb9de294623ab15636df707fe7c,
title = "Prostate brachytherapy seed reconstruction using an adaptive grouping technique",
abstract = "Fluoroscopy-based three-dimensional seed localization as a component of intraoperative dosimetry for prostate brachytherapy is an active area of research. A novel adaptive-grouping-based reconstruction approach is developed. This approach can recover overlapped seeds that are not detected from the fluoroscopic images. Two versions of the adaptive-grouping-based reconstruction approach are implemented and compared to an epipolar geometry-based seed reconstruction technique. Simulations based on nine patient datasets are used to validate the algorithms. A total of 2259 reconstructions is performed in which different types of error such as random noise in seed image locations and ambiguities in projection geometry are incorporated. Among those reconstructions, nine of the cases with overlapping seeds and the different types of error are performed. It is demonstrated that the adaptive-grouping- based reconstruction method is more accurate than the epipolar geometry method and allows faster reconstruction. At a random noise level of 0.6 mm, the mean distance error in reconstructed seed locations is approximately 1.0 mm for one of the relevant cases examined in detail. The best adaptive-grouping-based approach successfully recovered overlapped seeds in the majority of simulated cases (89{\%}), with the remainder of cases generating one false positive seed. Phantom validation is also performed, and overlapped seeds are successfully recovered with all 92 seeds correctly localized and reconstructed. The mean distance error between segmented seed images and projected seeds is 0.5 mm in the phantom study.",
keywords = "Brachytherapy, Fluoroscopy, Seed localization",
author = "Yi Su and Davis, {Brian J.} and Furutani, {Keith M.} and Herman, {Michael G.} and Robb, {Richard A.}",
year = "2007",
doi = "10.1118/1.2745936",
language = "English (US)",
volume = "34",
pages = "2975--2984",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "7",

}

TY - JOUR

T1 - Prostate brachytherapy seed reconstruction using an adaptive grouping technique

AU - Su, Yi

AU - Davis, Brian J.

AU - Furutani, Keith M.

AU - Herman, Michael G.

AU - Robb, Richard A.

PY - 2007

Y1 - 2007

N2 - Fluoroscopy-based three-dimensional seed localization as a component of intraoperative dosimetry for prostate brachytherapy is an active area of research. A novel adaptive-grouping-based reconstruction approach is developed. This approach can recover overlapped seeds that are not detected from the fluoroscopic images. Two versions of the adaptive-grouping-based reconstruction approach are implemented and compared to an epipolar geometry-based seed reconstruction technique. Simulations based on nine patient datasets are used to validate the algorithms. A total of 2259 reconstructions is performed in which different types of error such as random noise in seed image locations and ambiguities in projection geometry are incorporated. Among those reconstructions, nine of the cases with overlapping seeds and the different types of error are performed. It is demonstrated that the adaptive-grouping- based reconstruction method is more accurate than the epipolar geometry method and allows faster reconstruction. At a random noise level of 0.6 mm, the mean distance error in reconstructed seed locations is approximately 1.0 mm for one of the relevant cases examined in detail. The best adaptive-grouping-based approach successfully recovered overlapped seeds in the majority of simulated cases (89%), with the remainder of cases generating one false positive seed. Phantom validation is also performed, and overlapped seeds are successfully recovered with all 92 seeds correctly localized and reconstructed. The mean distance error between segmented seed images and projected seeds is 0.5 mm in the phantom study.

AB - Fluoroscopy-based three-dimensional seed localization as a component of intraoperative dosimetry for prostate brachytherapy is an active area of research. A novel adaptive-grouping-based reconstruction approach is developed. This approach can recover overlapped seeds that are not detected from the fluoroscopic images. Two versions of the adaptive-grouping-based reconstruction approach are implemented and compared to an epipolar geometry-based seed reconstruction technique. Simulations based on nine patient datasets are used to validate the algorithms. A total of 2259 reconstructions is performed in which different types of error such as random noise in seed image locations and ambiguities in projection geometry are incorporated. Among those reconstructions, nine of the cases with overlapping seeds and the different types of error are performed. It is demonstrated that the adaptive-grouping- based reconstruction method is more accurate than the epipolar geometry method and allows faster reconstruction. At a random noise level of 0.6 mm, the mean distance error in reconstructed seed locations is approximately 1.0 mm for one of the relevant cases examined in detail. The best adaptive-grouping-based approach successfully recovered overlapped seeds in the majority of simulated cases (89%), with the remainder of cases generating one false positive seed. Phantom validation is also performed, and overlapped seeds are successfully recovered with all 92 seeds correctly localized and reconstructed. The mean distance error between segmented seed images and projected seeds is 0.5 mm in the phantom study.

KW - Brachytherapy

KW - Fluoroscopy

KW - Seed localization

UR - http://www.scopus.com/inward/record.url?scp=34347382372&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34347382372&partnerID=8YFLogxK

U2 - 10.1118/1.2745936

DO - 10.1118/1.2745936

M3 - Article

VL - 34

SP - 2975

EP - 2984

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 7

ER -