TY - JOUR
T1 - Preferential Use of ePTFE For Above-Knee Femoropopliteal Bypass Grafts
AU - Patterson, Robert B.
AU - Fowl, Richard J.
AU - Kempczinski, Richard F.
AU - Gewirtz, Robert
AU - Shukla, Rakesh
PY - 1990
Y1 - 1990
N2 - We have used polytetrafluoroethylene preferentially for bypasses to the above-knee popliteal artery since 1979. Since this approach has recently been challenged, we reviewed our experience with 138 grafts in 128 patients. The majority (74%) of patients were male with a mean age of 63.2 years. Risk factors included: smoking (85%), hypertension (55%), diabetes mellitus (45%), and coronary artery disease (41%). The indications for operation were disabling claudication (18%), rest pain (42%), gangrene/tissue loss (33%), and miscellaneous (7%). Perioperative (30 day) mortality was 3% and morbidity (excluding amputation or graft failure) was 5%. Patients were followed for up to eight years with a mean follow-up of 22.1 months. Grafts which remained patent, but did not prevent major amputation, were classified as “failed”. Primary patency was 75% at one year and 54% at five years. Limb salvage was 88% at one year and 70% at five years. Risk factors, indication for operation and arteriographic runoff had no statistically significant impact on short- or long-term patency. However, bypass grafts to isolated popliteal segments had a significantly (p = 0.025) increased perioperative failure rate compared to all other grafts. Our data support the continued use of polytetrafluoroethylene for above-knee femoropopliteal bypass except perhaps in patients who require grafting to an isolated popliteal segment where higher early failure rates were seen.
AB - We have used polytetrafluoroethylene preferentially for bypasses to the above-knee popliteal artery since 1979. Since this approach has recently been challenged, we reviewed our experience with 138 grafts in 128 patients. The majority (74%) of patients were male with a mean age of 63.2 years. Risk factors included: smoking (85%), hypertension (55%), diabetes mellitus (45%), and coronary artery disease (41%). The indications for operation were disabling claudication (18%), rest pain (42%), gangrene/tissue loss (33%), and miscellaneous (7%). Perioperative (30 day) mortality was 3% and morbidity (excluding amputation or graft failure) was 5%. Patients were followed for up to eight years with a mean follow-up of 22.1 months. Grafts which remained patent, but did not prevent major amputation, were classified as “failed”. Primary patency was 75% at one year and 54% at five years. Limb salvage was 88% at one year and 70% at five years. Risk factors, indication for operation and arteriographic runoff had no statistically significant impact on short- or long-term patency. However, bypass grafts to isolated popliteal segments had a significantly (p = 0.025) increased perioperative failure rate compared to all other grafts. Our data support the continued use of polytetrafluoroethylene for above-knee femoropopliteal bypass except perhaps in patients who require grafting to an isolated popliteal segment where higher early failure rates were seen.
KW - Extended polytetrafluoroethylene grafts
KW - popliteal artery bypass
UR - http://www.scopus.com/inward/record.url?scp=0025074544&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025074544&partnerID=8YFLogxK
U2 - 10.1007/BF02000496
DO - 10.1007/BF02000496
M3 - Article
C2 - 2364049
AN - SCOPUS:0025074544
SN - 0890-5096
VL - 4
SP - 338
EP - 343
JO - Annals of Vascular Surgery
JF - Annals of Vascular Surgery
IS - 4
ER -