Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: An update for 2007 - An American Academy of Sleep Medicine Report

Timothy Ian Morgenthaler, R. Nisha Aurora, Terry Brown, Rochelle Zak, Cathy Alessi, Brian Boehlecke, Andrew L. Chesson, Leah Friedman, Vishesh Kapur, Rama Maganti, Judith Owens, Jeffrey Pancer, Todd J. Swick

Research output: Contribution to journalArticle

194 Citations (Scopus)

Abstract

These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

Original languageEnglish (US)
Pages (from-to)141-147
Number of pages7
JournalSleep
Volume31
Issue number1
StatePublished - Jan 1 2008

Fingerprint

Continuous Positive Airway Pressure
Obstructive Sleep Apnea
Sleep
Medicine
Pressure
Equipment and Supplies
Central Sleep Apnea
Chronic Obstructive Pulmonary Disease
Hypoventilation
Polysomnography
Therapeutics
Comorbidity
Obesity Hypoventilation Syndrome
Oxyhemoglobins
Airway Resistance
Palate

Keywords

  • APAP
  • Autotitrating
  • Continuous positive airway pressure
  • CPAP
  • Obstructive sleep apnea
  • Sleep disordered breathing

ASJC Scopus subject areas

  • Physiology

Cite this

Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome : An update for 2007 - An American Academy of Sleep Medicine Report. / Morgenthaler, Timothy Ian; Aurora, R. Nisha; Brown, Terry; Zak, Rochelle; Alessi, Cathy; Boehlecke, Brian; Chesson, Andrew L.; Friedman, Leah; Kapur, Vishesh; Maganti, Rama; Owens, Judith; Pancer, Jeffrey; Swick, Todd J.

In: Sleep, Vol. 31, No. 1, 01.01.2008, p. 141-147.

Research output: Contribution to journalArticle

Morgenthaler, Timothy Ian ; Aurora, R. Nisha ; Brown, Terry ; Zak, Rochelle ; Alessi, Cathy ; Boehlecke, Brian ; Chesson, Andrew L. ; Friedman, Leah ; Kapur, Vishesh ; Maganti, Rama ; Owens, Judith ; Pancer, Jeffrey ; Swick, Todd J. / Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome : An update for 2007 - An American Academy of Sleep Medicine Report. In: Sleep. 2008 ; Vol. 31, No. 1. pp. 141-147.
@article{897ca6e44efd4c609750b1082b9be7bc,
title = "Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: An update for 2007 - An American Academy of Sleep Medicine Report",
abstract = "These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.",
keywords = "APAP, Autotitrating, Continuous positive airway pressure, CPAP, Obstructive sleep apnea, Sleep disordered breathing",
author = "Morgenthaler, {Timothy Ian} and Aurora, {R. Nisha} and Terry Brown and Rochelle Zak and Cathy Alessi and Brian Boehlecke and Chesson, {Andrew L.} and Leah Friedman and Vishesh Kapur and Rama Maganti and Judith Owens and Jeffrey Pancer and Swick, {Todd J.}",
year = "2008",
month = "1",
day = "1",
language = "English (US)",
volume = "31",
pages = "141--147",
journal = "Sleep",
issn = "0161-8105",
publisher = "American Academy of Sleep Medicine",
number = "1",

}

TY - JOUR

T1 - Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome

T2 - An update for 2007 - An American Academy of Sleep Medicine Report

AU - Morgenthaler, Timothy Ian

AU - Aurora, R. Nisha

AU - Brown, Terry

AU - Zak, Rochelle

AU - Alessi, Cathy

AU - Boehlecke, Brian

AU - Chesson, Andrew L.

AU - Friedman, Leah

AU - Kapur, Vishesh

AU - Maganti, Rama

AU - Owens, Judith

AU - Pancer, Jeffrey

AU - Swick, Todd J.

PY - 2008/1/1

Y1 - 2008/1/1

N2 - These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

AB - These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

KW - APAP

KW - Autotitrating

KW - Continuous positive airway pressure

KW - CPAP

KW - Obstructive sleep apnea

KW - Sleep disordered breathing

UR - http://www.scopus.com/inward/record.url?scp=37549016362&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=37549016362&partnerID=8YFLogxK

M3 - Article

C2 - 18220088

AN - SCOPUS:37549016362

VL - 31

SP - 141

EP - 147

JO - Sleep

JF - Sleep

SN - 0161-8105

IS - 1

ER -