Polymeric stenting in the porcine coronary artery model: Differential outcome of exogenous fibrin sleeves versus polyurethane-coated stents

David R. Holmes, Allan R. Camrud, Michael A. Jorgenson, William D. Edwards, Robert S. Schwartz

Research output: Contribution to journalArticlepeer-review

86 Scopus citations

Abstract

Objectives. In a porcine coronary model, fibrin film soaked for 3 h in heparin was used as a circumferential coating on a tantalum stent to assess the effect of this naturally occurring biopolymer on arterial healing. The results were compared with those obtained with medical grade polyurethane-coated stainless steel stents. Background. Thrombus plays an important role in healing after arterial injury and may affect the development of neointimal hyperplasia. Manipulation of the initial thrombus may alter the healing response. To study this, we placed a template of fibrin in a porcine coronary artery restenosis model. Methods. Thirty-four fibrin film stents were delivered in 20 swine. Oversizing was avoided, to prevent deep arterial injury, by placement of optimally sized stents. Initial patency of the syented vessel was confirmed by angiography. Results. Three fibrin-stented swine died within 48 h; in each, the stent was occluded with a fibrin/red blood cell mass. In two of these three, a portion of the exogenous fibrin had become detached from the stent and partially occluded the lumen. Of the remaining 31 stents, all were patent at elective sacrifice at 28 days. Eightyfour percent had a diameter stenosis <50%, and the mean (± SD) diameter stenosis was 32.3 ± 13%. There was no evidence of significant foreign-body giant-cell reaction. These results contrasted with the medical grade polyurethane-coated stents placed according to the same protocol without oversizing. Twelve of these stents were placed; six swine died of thrombotic occlusion within the 1st 48 h. At elective sacrifice at 28 days, the remaining polyurethane-coated stents were occluded by marked neointimal hyperplasia. Conclusions. Fibrin film-coated stents seem promising as a template for modifying the local response to arterial injury and for potentially decreasing restenosis rates.

Original languageEnglish (US)
Pages (from-to)525-531
Number of pages7
JournalJournal of the American College of Cardiology
Volume24
Issue number2
DOIs
StatePublished - Aug 1994

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Polymeric stenting in the porcine coronary artery model: Differential outcome of exogenous fibrin sleeves versus polyurethane-coated stents'. Together they form a unique fingerprint.

Cite this