Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.

Original languageEnglish (US)
Pages (from-to)652-657
Number of pages6
JournalJournal of Arthroplasty
Volume19
Issue number5
DOIs
StatePublished - Aug 2004
Externally publishedYes

Fingerprint

Knee Replacement Arthroplasties
Polyethylene
Prostheses and Implants
Thigh
Arthrography
Joints
Tomography
Therapeutics

Keywords

  • complications
  • component failure
  • polyethylene wear
  • total knee arthroplasty

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Polyethylene post failure in posterior stabilized total knee arthroplasty. / Clarke, Henry D.; Math, Kevin R.; Scuderi, Giles R.

In: Journal of Arthroplasty, Vol. 19, No. 5, 08.2004, p. 652-657.

Research output: Contribution to journalReview article

Clarke, Henry D. ; Math, Kevin R. ; Scuderi, Giles R. / Polyethylene post failure in posterior stabilized total knee arthroplasty. In: Journal of Arthroplasty. 2004 ; Vol. 19, No. 5. pp. 652-657.
@article{eefdf357e35345659fc3dc373d5443cc,
title = "Polyethylene post failure in posterior stabilized total knee arthroplasty",
abstract = "Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.",
keywords = "complications, component failure, polyethylene wear, total knee arthroplasty",
author = "Clarke, {Henry D.} and Math, {Kevin R.} and Scuderi, {Giles R.}",
year = "2004",
month = "8",
doi = "10.1016/j.arth.2004.02.026",
language = "English (US)",
volume = "19",
pages = "652--657",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "5",

}

TY - JOUR

T1 - Polyethylene post failure in posterior stabilized total knee arthroplasty

AU - Clarke, Henry D.

AU - Math, Kevin R.

AU - Scuderi, Giles R.

PY - 2004/8

Y1 - 2004/8

N2 - Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.

AB - Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.

KW - complications

KW - component failure

KW - polyethylene wear

KW - total knee arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=3342936437&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3342936437&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2004.02.026

DO - 10.1016/j.arth.2004.02.026

M3 - Review article

C2 - 15284990

AN - SCOPUS:3342936437

VL - 19

SP - 652

EP - 657

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 5

ER -