TY - JOUR
T1 - Pairing 40-mm Femoral Heads With the Smallest Compatible Acetabular Components in Total Hip Arthroplasty
T2 - Mid-Term Outcomes in 177 Cases
AU - Bukowski, Brandon R.
AU - Baker, Courtney E.
AU - Abdel, Matthew P.
AU - Trousdale, Robert T.
N1 - Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2022/7
Y1 - 2022/7
N2 - Background: Contemporary total hip arthroplasty (THA) often employs larger femoral heads to optimize hip stability. However, pairing 40-mm femoral heads with the smallest compatible acetabular components poses a potential risk for implant failure. The purpose of this study is to evaluate the outcomes of primary THAs using 40-mm femoral heads and the smallest compatible acetabular components. Methods: Between 2007 and 2018, 177 primary THAs involving 40-mm femoral heads and acetabular components ≤56 mm with highly cross-linked polyethylene liners were identified. Mean age was 61 years, 56% were females, and mean body mass index was 32 kg/m2. Cumulative incidences of dislocation, any revision, and any reoperation were determined utilizing a competing risk model. Osteolysis and femoral head penetration were assessed at minimum 8-year follow-up (n = 16). Mean follow-up was 6 years. Results: There were no cases of liner fractures or dissociations. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.6%, 4.2%, and 6.8%, respectively. Mean linear femoral head penetration was 0.01 mm/y and mean volumetric wear rate was 50 mm3/y. One THA demonstrated stable, asymptomatic periacetabular radiolucent lines at most recent follow-up. Conclusion: In 177 primary THAs pairing 40-mm femoral heads with the smallest compatible acetabular components, there were no liner fractures or dissociations. The cumulative incidence of dislocation was modest at 10 years. The cumulative incidences of any revision and any reoperation were low at mid-term. Level of Evidence: IV.
AB - Background: Contemporary total hip arthroplasty (THA) often employs larger femoral heads to optimize hip stability. However, pairing 40-mm femoral heads with the smallest compatible acetabular components poses a potential risk for implant failure. The purpose of this study is to evaluate the outcomes of primary THAs using 40-mm femoral heads and the smallest compatible acetabular components. Methods: Between 2007 and 2018, 177 primary THAs involving 40-mm femoral heads and acetabular components ≤56 mm with highly cross-linked polyethylene liners were identified. Mean age was 61 years, 56% were females, and mean body mass index was 32 kg/m2. Cumulative incidences of dislocation, any revision, and any reoperation were determined utilizing a competing risk model. Osteolysis and femoral head penetration were assessed at minimum 8-year follow-up (n = 16). Mean follow-up was 6 years. Results: There were no cases of liner fractures or dissociations. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.6%, 4.2%, and 6.8%, respectively. Mean linear femoral head penetration was 0.01 mm/y and mean volumetric wear rate was 50 mm3/y. One THA demonstrated stable, asymptomatic periacetabular radiolucent lines at most recent follow-up. Conclusion: In 177 primary THAs pairing 40-mm femoral heads with the smallest compatible acetabular components, there were no liner fractures or dissociations. The cumulative incidence of dislocation was modest at 10 years. The cumulative incidences of any revision and any reoperation were low at mid-term. Level of Evidence: IV.
KW - highly crosslinked polyethylene
KW - large femoral heads
KW - polyethylene wear
KW - small acetabular components
KW - total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85125741308&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85125741308&partnerID=8YFLogxK
U2 - 10.1016/j.arth.2022.01.090
DO - 10.1016/j.arth.2022.01.090
M3 - Article
C2 - 35256235
AN - SCOPUS:85125741308
SN - 0883-5403
VL - 37
SP - S582-S587
JO - Journal of Arthroplasty
JF - Journal of Arthroplasty
IS - 7
ER -