TY - JOUR
T1 - Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents
AU - Doyle, Brendan
AU - Rihal, Charanjit S.
AU - O'Sullivan, Crochan J.
AU - Lennon, Ryan J.
AU - Wiste, Heather J.
AU - Bell, Malcolm
AU - Bresnahan, John
AU - Holmes, David R.
PY - 2007/11/1
Y1 - 2007/11/1
N2 - BACKGROUND - Concern regarding risk of late thrombosis after "off-label" treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized. METHODS AND RESULTS - We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (>1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use (P=0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased (P=0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion (P<0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P<0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P<0.001). CONCLUSIONS - The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.
AB - BACKGROUND - Concern regarding risk of late thrombosis after "off-label" treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized. METHODS AND RESULTS - We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (>1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use (P=0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased (P=0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion (P<0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P<0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P<0.001). CONCLUSIONS - The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.
KW - Myocardial infarction
KW - Restenosis
KW - Stents
KW - Thrombosis
UR - http://www.scopus.com/inward/record.url?scp=36348952607&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=36348952607&partnerID=8YFLogxK
U2 - 10.1161/CIRCULATIONAHA.107.707331
DO - 10.1161/CIRCULATIONAHA.107.707331
M3 - Article
C2 - 17984377
AN - SCOPUS:36348952607
SN - 0009-7322
VL - 116
SP - 2391
EP - 2398
JO - Circulation
JF - Circulation
IS - 21
ER -