Objectives: Magnetic resonance elastography (MRE) has excellent performance in detecting liver fibrosis and is becoming an alternative to liver biopsy in clinical practice. Ultrasound techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force also have shown promising results for liver fibrosis staging. The objective of this study was to compare ultrasound-based shear wave measurement to MRE.

Methods: In this study, 50 patients (28 female and 22 male; age range, 19-81 years) undergoing liver MRE examinations were studied with an ultrasound scanner modified with shear wave measurement functionality. For each patient, 27 shear wave speed measurements were obtained at various locations in the liver parenchyma away from major vessels. The median shear wave speed from all measurements was used to calculate a representative shear modulus (μ) for each patient. Magnetic resonance elastographic data processing was done by a single analyst blinded to the ultrasound measurement results.

Results: Ultrasound and MRE measurements were correlated (r = 0.86; P < .001). Receiver operating characteristic (ROC) analysis was applied to the ultrasound measurement results with the MRE diagnosis as the "ground truth." The area under the ROC curve for separating patients with minimum fibrosis (defined as μMRE ≤2.9 kPa) was 0.89 (95% confidence interval, 0.77-0.95), and the area under the ROC curve for separating patients with advanced fibrosis (defined as μMRE ≥5.0 kPa) was 0.96 (95% confidence interval, 0.87-0.99).

Conclusions: Results indicate that the ultrasound-based shear wave measurement correlates with MRE and is a promising method for liver fibrosis staging.

Original languageEnglish (US)
Pages (from-to)1597-1604
Number of pages8
JournalJournal of Ultrasound in Medicine
Volume33
Issue number9
DOIs
StatePublished - Sep 1 2014

Keywords

  • Gastrointestinal ultrasound
  • Liver fibrosis
  • Magnetic resonance elastography
  • Shear wave
  • Ultrasound

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Noninvasive assessment of liver fibrosis using ultrasound-based shear wave measurement and comparison to magnetic resonance elastography'. Together they form a unique fingerprint.

Cite this