Noise reduction to decrease radiation dose and improve conspicuity of hepatic lesions at contrast-enhanced 80-kV hepatic CT using projection space denoising

Eric C. Ehman, Luís S. Guimarães, Jeff L. Fidler, Naoki Takahashi, Juan Carlos Ramirez-Giraldo, Lifeng Yu, Armando Manduca, James E. Huprich, Cynthia H. McCollough, David Holmes, W. Scott Harmsen, Joel G. Fletcher

Research output: Contribution to journalArticlepeer-review

30 Scopus citations

Abstract

OBJECTIVE. The purpose of this study was to investigate the combined potential of 80- kV CT and noise reduction using a projection space denoising algorithm to reduce radiation dose reduction or to improve the image quality of hepatic CT. MATERIALS AND Met hods . Twenty patients with 56 liver lesions underwent dualenergy (80 and 140 kV) contrast-enhanced hepatic CT. Low-dose 80-kV-only images (comprising 26-54% of the total radiation dose), low-dose 80-kV projection space denoising images (routine and sharper reconstruction kernel), and full-dose mixed-kilovoltage with projection space denoising images were evaluated by three radiologists for lesion conspicuity, image noise, and sharpness. Lesions were compared with full-dose images using 5-point scales (0 = no change, +2 = markedly better, and -2 = markedly worse). Quantitative conspicuity in the form of lesion-to-liver contrast-to-noise ratio (CNR), image noise, and image sharpness were measured. RESULTS. For all readers, the mean conspicuity rating of low-dose 80-kV projection space denoising images was better than that for full-dose images (mean conspicuity, 0.36-0.57; p < 0.001), with only 1.2% of lesions less conspicuous on 80-kV projection space denoising images. Eighty-kilovolt projection space denoising images reconstructed with a sharper kernel were subjectively similar to full-dose mixed-kilovoltage images comparing image noise (-0.054 to 0.018; p < 0.001 to p = 0.058) and sharpness (-0.64 to -0.09; p < 0.001 to p = 0.057). For 80-kV projection space denoising images with a sharper kernel, lesion-to-liver CNR was slightly higher than that for full-dose mixed-kilovoltage images (p < 0.001), whereas image sharpness and noise were unchanged (p = 0.74 and p = 0.02). CONCLUSION. Eighty-kilovolt imaging with noise reduction can simultaneously increase lesion conspicuity and facilitate radiation dose reduction and image quality improvement at contrast-enhanced hepatic CT.

Original languageEnglish (US)
Pages (from-to)405-411
Number of pages7
JournalAmerican Journal of Roentgenology
Volume198
Issue number2
DOIs
StatePublished - Feb 2012

Keywords

  • Hepatic CT
  • Low tube potential
  • Noise reduction
  • Radiation dose
  • Reconstruction technique

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Noise reduction to decrease radiation dose and improve conspicuity of hepatic lesions at contrast-enhanced 80-kV hepatic CT using projection space denoising'. Together they form a unique fingerprint.

Cite this