Narrow-band imaging system with magnifying endoscopy for superficial esophageal lesions

Tatsuya Yoshida, Haruhiro Inoue, Shinsuke Usui, Hitoshi Satodate, Norio Fukami, Shin Ei Kudo

Research output: Contribution to journalArticle

352 Citations (Scopus)

Abstract

Background: By assessing the intrapapillary capillary loop in esophageal mucosa, magnifying endoscopy can play an important role in the evaluation of superficial esophageal lesions. A newly developed narrow-band imaging system was applied to magnifying endoscopy in a clinical setting; the benefit of the narrow-band imaging system was evaluated. Methods: Forty-one patients (37 men, 4 women; mean age 63.5 [7.3] years) were enrolled between March 2002 and January 2003 in the study. Endoscopy was performed with a magnifying endoscope, a standard video-endoscopic system, and a narrow-band imaging system. The assessment consisted of 3 phases: a numerical analysis of the red, green, blue color value of endoscopic images, creation of model images, and assessment on the actual images. In the numerical analysis, the red, green, blue color value for intrapapillary capillary loop and background mucosa were obtained, and the ratio and contrast value were calculated. Results: In the numerical analysis, both the ratio and the contrast value between the intrapapillary capillary loop and background mucosa were statistically different. Based on an evaluation of created model images, almost all assessors found the narrow-band imaging system to be superior. In the assessment of actual images, the narrow-band imaging system improved overall accuracy for depth of invasion, especially for inexperienced endoscopists. Conclusions: The narrow-band imaging system improved the accuracy of magnifying endoscopy for assessment of esophageal lesion.

Original languageEnglish (US)
Pages (from-to)288-295
Number of pages8
JournalGastrointestinal Endoscopy
Volume59
Issue number2
DOIs
StatePublished - Feb 1 2004
Externally publishedYes

Fingerprint

Narrow Band Imaging
Endoscopy
Mucous Membrane
Color
Endoscopes

ASJC Scopus subject areas

  • Gastroenterology

Cite this

Narrow-band imaging system with magnifying endoscopy for superficial esophageal lesions. / Yoshida, Tatsuya; Inoue, Haruhiro; Usui, Shinsuke; Satodate, Hitoshi; Fukami, Norio; Kudo, Shin Ei.

In: Gastrointestinal Endoscopy, Vol. 59, No. 2, 01.02.2004, p. 288-295.

Research output: Contribution to journalArticle

Yoshida, Tatsuya ; Inoue, Haruhiro ; Usui, Shinsuke ; Satodate, Hitoshi ; Fukami, Norio ; Kudo, Shin Ei. / Narrow-band imaging system with magnifying endoscopy for superficial esophageal lesions. In: Gastrointestinal Endoscopy. 2004 ; Vol. 59, No. 2. pp. 288-295.
@article{e4c8bbaffbcd45b5b35de4cb58a73b59,
title = "Narrow-band imaging system with magnifying endoscopy for superficial esophageal lesions",
abstract = "Background: By assessing the intrapapillary capillary loop in esophageal mucosa, magnifying endoscopy can play an important role in the evaluation of superficial esophageal lesions. A newly developed narrow-band imaging system was applied to magnifying endoscopy in a clinical setting; the benefit of the narrow-band imaging system was evaluated. Methods: Forty-one patients (37 men, 4 women; mean age 63.5 [7.3] years) were enrolled between March 2002 and January 2003 in the study. Endoscopy was performed with a magnifying endoscope, a standard video-endoscopic system, and a narrow-band imaging system. The assessment consisted of 3 phases: a numerical analysis of the red, green, blue color value of endoscopic images, creation of model images, and assessment on the actual images. In the numerical analysis, the red, green, blue color value for intrapapillary capillary loop and background mucosa were obtained, and the ratio and contrast value were calculated. Results: In the numerical analysis, both the ratio and the contrast value between the intrapapillary capillary loop and background mucosa were statistically different. Based on an evaluation of created model images, almost all assessors found the narrow-band imaging system to be superior. In the assessment of actual images, the narrow-band imaging system improved overall accuracy for depth of invasion, especially for inexperienced endoscopists. Conclusions: The narrow-band imaging system improved the accuracy of magnifying endoscopy for assessment of esophageal lesion.",
author = "Tatsuya Yoshida and Haruhiro Inoue and Shinsuke Usui and Hitoshi Satodate and Norio Fukami and Kudo, {Shin Ei}",
year = "2004",
month = "2",
day = "1",
doi = "10.1016/S0016-5107(03)02532-X",
language = "English (US)",
volume = "59",
pages = "288--295",
journal = "Gastrointestinal Endoscopy",
issn = "0016-5107",
publisher = "Mosby Inc.",
number = "2",

}

TY - JOUR

T1 - Narrow-band imaging system with magnifying endoscopy for superficial esophageal lesions

AU - Yoshida, Tatsuya

AU - Inoue, Haruhiro

AU - Usui, Shinsuke

AU - Satodate, Hitoshi

AU - Fukami, Norio

AU - Kudo, Shin Ei

PY - 2004/2/1

Y1 - 2004/2/1

N2 - Background: By assessing the intrapapillary capillary loop in esophageal mucosa, magnifying endoscopy can play an important role in the evaluation of superficial esophageal lesions. A newly developed narrow-band imaging system was applied to magnifying endoscopy in a clinical setting; the benefit of the narrow-band imaging system was evaluated. Methods: Forty-one patients (37 men, 4 women; mean age 63.5 [7.3] years) were enrolled between March 2002 and January 2003 in the study. Endoscopy was performed with a magnifying endoscope, a standard video-endoscopic system, and a narrow-band imaging system. The assessment consisted of 3 phases: a numerical analysis of the red, green, blue color value of endoscopic images, creation of model images, and assessment on the actual images. In the numerical analysis, the red, green, blue color value for intrapapillary capillary loop and background mucosa were obtained, and the ratio and contrast value were calculated. Results: In the numerical analysis, both the ratio and the contrast value between the intrapapillary capillary loop and background mucosa were statistically different. Based on an evaluation of created model images, almost all assessors found the narrow-band imaging system to be superior. In the assessment of actual images, the narrow-band imaging system improved overall accuracy for depth of invasion, especially for inexperienced endoscopists. Conclusions: The narrow-band imaging system improved the accuracy of magnifying endoscopy for assessment of esophageal lesion.

AB - Background: By assessing the intrapapillary capillary loop in esophageal mucosa, magnifying endoscopy can play an important role in the evaluation of superficial esophageal lesions. A newly developed narrow-band imaging system was applied to magnifying endoscopy in a clinical setting; the benefit of the narrow-band imaging system was evaluated. Methods: Forty-one patients (37 men, 4 women; mean age 63.5 [7.3] years) were enrolled between March 2002 and January 2003 in the study. Endoscopy was performed with a magnifying endoscope, a standard video-endoscopic system, and a narrow-band imaging system. The assessment consisted of 3 phases: a numerical analysis of the red, green, blue color value of endoscopic images, creation of model images, and assessment on the actual images. In the numerical analysis, the red, green, blue color value for intrapapillary capillary loop and background mucosa were obtained, and the ratio and contrast value were calculated. Results: In the numerical analysis, both the ratio and the contrast value between the intrapapillary capillary loop and background mucosa were statistically different. Based on an evaluation of created model images, almost all assessors found the narrow-band imaging system to be superior. In the assessment of actual images, the narrow-band imaging system improved overall accuracy for depth of invasion, especially for inexperienced endoscopists. Conclusions: The narrow-band imaging system improved the accuracy of magnifying endoscopy for assessment of esophageal lesion.

UR - http://www.scopus.com/inward/record.url?scp=1042266566&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1042266566&partnerID=8YFLogxK

U2 - 10.1016/S0016-5107(03)02532-X

DO - 10.1016/S0016-5107(03)02532-X

M3 - Article

VL - 59

SP - 288

EP - 295

JO - Gastrointestinal Endoscopy

JF - Gastrointestinal Endoscopy

SN - 0016-5107

IS - 2

ER -