TY - GEN
T1 - Muscular forces and joint angles in small-handed pianists
T2 - 49th Annual Meeting of the Human Factors and Ergonomics Society, HFES 2005
AU - Wristen, B. G.
AU - Wismer, A. K.G.
AU - Jung, M. C.
AU - Hallbeck, M. S.
PY - 2005
Y1 - 2005
N2 - This pilot study examined whether the use of a 7/8 keyboard contributed to the physical ease of small-handed pianists in comparison with the conventional piano keyboard. A secondary research question focused on the transition from one keyboard to the other. For the purposes of this study, we adopted David Steinbuhler's postulated hand span of 8 inches or less as defining a "small-handed" pianist. The goal was to measure muscle loading and hand span during performance of the excerpt. Data collection included each participant being monitored using electromyography via surface electrodes, which were attached to the upper back/shoulder, parts of the hand and arm, and the masseter muscle of the jaw. Subjects were also fitted with electrogoniometers to capture how the span from the first metacarpophalangeal (MCP) joint to the fifth MCP joint moved according to performance demands, as well as recording wrist flexion and extension, radial and ulnar deviation. The findings were that smallhanded pianists preferred the smaller keyboard and were able to transition smoothly between it and the conventional keyboard. The maximal angle of hand span while playing a difficult piece averaged about 5° smaller on the radial side and 10° smaller on the ulnar side for the 7/8 keyboard, leading to perceived comfort (ease) and better performance as rated by the subjects.
AB - This pilot study examined whether the use of a 7/8 keyboard contributed to the physical ease of small-handed pianists in comparison with the conventional piano keyboard. A secondary research question focused on the transition from one keyboard to the other. For the purposes of this study, we adopted David Steinbuhler's postulated hand span of 8 inches or less as defining a "small-handed" pianist. The goal was to measure muscle loading and hand span during performance of the excerpt. Data collection included each participant being monitored using electromyography via surface electrodes, which were attached to the upper back/shoulder, parts of the hand and arm, and the masseter muscle of the jaw. Subjects were also fitted with electrogoniometers to capture how the span from the first metacarpophalangeal (MCP) joint to the fifth MCP joint moved according to performance demands, as well as recording wrist flexion and extension, radial and ulnar deviation. The findings were that smallhanded pianists preferred the smaller keyboard and were able to transition smoothly between it and the conventional keyboard. The maximal angle of hand span while playing a difficult piece averaged about 5° smaller on the radial side and 10° smaller on the ulnar side for the 7/8 keyboard, leading to perceived comfort (ease) and better performance as rated by the subjects.
UR - http://www.scopus.com/inward/record.url?scp=44349163991&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=44349163991&partnerID=8YFLogxK
U2 - 10.1177/154193120504901816
DO - 10.1177/154193120504901816
M3 - Conference contribution
AN - SCOPUS:44349163991
SN - 094528926X
SN - 9780945289265
T3 - Proceedings of the Human Factors and Ergonomics Society
SP - 1752
EP - 1756
BT - Proceedings of the Human Factors and Ergonomics Society 49th Annual Meeting, HFES 2005
PB - Human Factors and Ergonomics Society Inc.
Y2 - 26 September 2005 through 30 September 2005
ER -