Multiscale electrophysiology format: an open-source electrophysiology format using data compression, encryption, and cyclic redundancy check.

Benjamin H. Brinkmann, Mark R. Bower, Keith A. Stengel, Gregory A. Worrell, Matt Stead

Research output: Contribution to journalArticle

Abstract

Continuous, long-term (up to 10 days) electrophysiological monitoring using hybrid intracranial electrodes is an emerging tool for presurgical epilepsy evaluation and fundamental investigations of seizure generation. Detection of high-frequency oscillations and microseizures could provide valuable insights into causes and therapies for the treatment of epilepsy, but requires high spatial and temporal resolution. Our group is currently using hybrid arrays composed of up to 320 micro- and clinical macroelectrode arrays sampled at 32 kHz per channel with 18-bits of A/D resolution. Such recordings produce approximately 3 terabytes of data per day. Existing file formats have limited data compression capabilities, and do not offer mechanisms for protecting patient identifying information or detecting data corruption during transmission or storage. We present a novel file format that employs range encoding to provide a high degree of data compression, a three-tiered 128-bit encryption system for patient information and data security, and a 32-bit cyclic redundancy check to verify the integrity of compressed data blocks. Open-source software to read, write, and process these files are provided.

Original languageEnglish (US)
Pages (from-to)7083-7086
Number of pages4
JournalConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
StatePublished - 2009
Externally publishedYes

Fingerprint

Data Compression
Electrophysiology
Computer Security
Data compression
Cryptography
Redundancy
Epilepsy
Security of data
Information Systems
Electrodes
Seizures
Software
Therapeutics
Monitoring

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Signal Processing
  • Biomedical Engineering
  • Health Informatics

Cite this

@article{ea87aad548c642ea953659dfbcf85d98,
title = "Multiscale electrophysiology format: an open-source electrophysiology format using data compression, encryption, and cyclic redundancy check.",
abstract = "Continuous, long-term (up to 10 days) electrophysiological monitoring using hybrid intracranial electrodes is an emerging tool for presurgical epilepsy evaluation and fundamental investigations of seizure generation. Detection of high-frequency oscillations and microseizures could provide valuable insights into causes and therapies for the treatment of epilepsy, but requires high spatial and temporal resolution. Our group is currently using hybrid arrays composed of up to 320 micro- and clinical macroelectrode arrays sampled at 32 kHz per channel with 18-bits of A/D resolution. Such recordings produce approximately 3 terabytes of data per day. Existing file formats have limited data compression capabilities, and do not offer mechanisms for protecting patient identifying information or detecting data corruption during transmission or storage. We present a novel file format that employs range encoding to provide a high degree of data compression, a three-tiered 128-bit encryption system for patient information and data security, and a 32-bit cyclic redundancy check to verify the integrity of compressed data blocks. Open-source software to read, write, and process these files are provided.",
author = "Brinkmann, {Benjamin H.} and Bower, {Mark R.} and Stengel, {Keith A.} and Worrell, {Gregory A.} and Matt Stead",
year = "2009",
language = "English (US)",
pages = "7083--7086",
journal = "Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference",
issn = "1557-170X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - Multiscale electrophysiology format

T2 - an open-source electrophysiology format using data compression, encryption, and cyclic redundancy check.

AU - Brinkmann, Benjamin H.

AU - Bower, Mark R.

AU - Stengel, Keith A.

AU - Worrell, Gregory A.

AU - Stead, Matt

PY - 2009

Y1 - 2009

N2 - Continuous, long-term (up to 10 days) electrophysiological monitoring using hybrid intracranial electrodes is an emerging tool for presurgical epilepsy evaluation and fundamental investigations of seizure generation. Detection of high-frequency oscillations and microseizures could provide valuable insights into causes and therapies for the treatment of epilepsy, but requires high spatial and temporal resolution. Our group is currently using hybrid arrays composed of up to 320 micro- and clinical macroelectrode arrays sampled at 32 kHz per channel with 18-bits of A/D resolution. Such recordings produce approximately 3 terabytes of data per day. Existing file formats have limited data compression capabilities, and do not offer mechanisms for protecting patient identifying information or detecting data corruption during transmission or storage. We present a novel file format that employs range encoding to provide a high degree of data compression, a three-tiered 128-bit encryption system for patient information and data security, and a 32-bit cyclic redundancy check to verify the integrity of compressed data blocks. Open-source software to read, write, and process these files are provided.

AB - Continuous, long-term (up to 10 days) electrophysiological monitoring using hybrid intracranial electrodes is an emerging tool for presurgical epilepsy evaluation and fundamental investigations of seizure generation. Detection of high-frequency oscillations and microseizures could provide valuable insights into causes and therapies for the treatment of epilepsy, but requires high spatial and temporal resolution. Our group is currently using hybrid arrays composed of up to 320 micro- and clinical macroelectrode arrays sampled at 32 kHz per channel with 18-bits of A/D resolution. Such recordings produce approximately 3 terabytes of data per day. Existing file formats have limited data compression capabilities, and do not offer mechanisms for protecting patient identifying information or detecting data corruption during transmission or storage. We present a novel file format that employs range encoding to provide a high degree of data compression, a three-tiered 128-bit encryption system for patient information and data security, and a 32-bit cyclic redundancy check to verify the integrity of compressed data blocks. Open-source software to read, write, and process these files are provided.

UR - http://www.scopus.com/inward/record.url?scp=84903854883&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903854883&partnerID=8YFLogxK

M3 - Article

C2 - 19963940

SP - 7083

EP - 7086

JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference

JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference

SN - 1557-170X