TY - JOUR
T1 - Multicenter comparison of three intraoperative hemoglobin trend monitoring methods
AU - Applegate, Richard L.
AU - Applegate, Patricia M.
AU - Cannesson, Maxime
AU - Peiris, Prith
AU - Ladlie, Beth L.
AU - Torp, Klaus
N1 - Funding Information:
Funding and material support for this study was provided by grants from Masimo Corporation to the Anesthesiology Departments at Loma Linda University School of Medicine (RA), Mayo Clinic in Florida (KT) and the University of California Irvine (MC) where the work was performed. The study protocol, conduct, analysis and write up were all under the control of the investigators.
Funding Information:
The authors acknowledge the assistance of Tristan Grogan MS, Principal Statistician, Division of General Internal Medicine and Health Services Research, University of California Los Angeles, and the research assistance of Gerald D. Andrews MBBS and Michael-David Calderon, BS.
Publisher Copyright:
© 2019, The Author(s).
PY - 2020/10/1
Y1 - 2020/10/1
N2 - Transfusion decisions are guided by clinical factors and measured hemoglobin (Hb). Time required for blood sampling and analysis may cause Hb measurement to lag clinical conditions, thus continuous intraoperative Hb trend monitoring may provide useful information. This multicenter study was designed to compare three methods of determining intraoperative Hb changes (trend accuracy) to laboratory determined Hb changes. Adult surgical patients with planned arterial catheterization were studied. With each blood gas analysis performed, pulse cooximetry hemoglobin (SpHb) was recorded, and arterial blood Hb was measured by hematology (tHb), arterial blood gas cooximetry (ABGHb), and point of care (aHQHb) analyzers. Hb change was calculated and trend accuracy assessed by modified Bland–Altman analysis. Secondary measures included Hb measurement change direction agreement. Trend accuracy mean bias (95% limits of agreement; g/dl) for SpHb was 0.10 (− 1.14 to 1.35); for ABGHb was − 0.02 (− 1.06 to 1.02); and for aHQHb was 0.003 (− 0.95 to 0.95). Changes more than ± 0.5 g/dl agreed with tHb changes more than ± 0.25 g/dl in 94.2% (88.9–97.0%) SpHb changes, 98.9% (96.1–99.7%) ABGHb changes and 99.0% (96.4–99.7%) aHQHb changes. Sequential changes in SpHb, ABGHb and aHQHb exceeding ± 0.5 g/dl have similar agreement to the direction but not necessarily the magnitude of sequential tHb change. While Hb blood tests should continue to be used to inform transfusion decisions, intraoperative continuous noninvasive SpHb decreases more than − 0.5 g/dl could be a good indicator of the need to measure tHb.
AB - Transfusion decisions are guided by clinical factors and measured hemoglobin (Hb). Time required for blood sampling and analysis may cause Hb measurement to lag clinical conditions, thus continuous intraoperative Hb trend monitoring may provide useful information. This multicenter study was designed to compare three methods of determining intraoperative Hb changes (trend accuracy) to laboratory determined Hb changes. Adult surgical patients with planned arterial catheterization were studied. With each blood gas analysis performed, pulse cooximetry hemoglobin (SpHb) was recorded, and arterial blood Hb was measured by hematology (tHb), arterial blood gas cooximetry (ABGHb), and point of care (aHQHb) analyzers. Hb change was calculated and trend accuracy assessed by modified Bland–Altman analysis. Secondary measures included Hb measurement change direction agreement. Trend accuracy mean bias (95% limits of agreement; g/dl) for SpHb was 0.10 (− 1.14 to 1.35); for ABGHb was − 0.02 (− 1.06 to 1.02); and for aHQHb was 0.003 (− 0.95 to 0.95). Changes more than ± 0.5 g/dl agreed with tHb changes more than ± 0.25 g/dl in 94.2% (88.9–97.0%) SpHb changes, 98.9% (96.1–99.7%) ABGHb changes and 99.0% (96.4–99.7%) aHQHb changes. Sequential changes in SpHb, ABGHb and aHQHb exceeding ± 0.5 g/dl have similar agreement to the direction but not necessarily the magnitude of sequential tHb change. While Hb blood tests should continue to be used to inform transfusion decisions, intraoperative continuous noninvasive SpHb decreases more than − 0.5 g/dl could be a good indicator of the need to measure tHb.
KW - Hemoglobin
KW - Intraoperative monitoring
KW - Noninvasive measurement
KW - Point of care tests
UR - http://www.scopus.com/inward/record.url?scp=85076004604&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85076004604&partnerID=8YFLogxK
U2 - 10.1007/s10877-019-00428-3
DO - 10.1007/s10877-019-00428-3
M3 - Article
C2 - 31797199
AN - SCOPUS:85076004604
SN - 1387-1307
VL - 34
SP - 883
EP - 892
JO - Journal of Clinical Monitoring and Computing
JF - Journal of Clinical Monitoring and Computing
IS - 5
ER -