MR findings of collateral circulation are more accurate measures of hemodynamic significance than arm-leg blood pressure gradient after repair of coarctation of the aorta

Philip A. Araoz, Gautham P. Reddy, Harold Tarnoff, Claude L. Roge, Charles B. Higgins

Research output: Contribution to journalArticlepeer-review

52 Scopus citations

Abstract

Purpose: To determine the relationship between percent stenosis and three indicators of hemodynamic significance - arm-leg blood pressure gradient, direct visualization of collaterals, and percent increase flow from proximal to distal descending thoracic aorta - in patients with prior repair of coarctation of the aorta (CoA). Materials and Methods: Magnetic resonance imaging (MRI) examinations of 19 patients with prior repair of CoA were retrospectively reviewed. Percent stenosis was compared to the arm-leg blood pressure gradient as obtained from chart review, the depiction of collaterals by gadolinium-enhanced magnetic resonance angiography (MRA), and the percent increased flow in the distal thoracic aorta as measured by velocity-encoded cine MRI. Some imaging series or blood-pressure values were not available in some patients. All of the data were available for 15 of the 19 patients. Results: The arm-leg blood pressure gradient showed no statistical association with percent stenosis (R2 = 0.10, P = 0.22), direct visualization of collaterals (P = 0.80), or percent increase in flow (R2 < 0.01, P = 0.85). Percent stenosis did show association with visualization of collaterals (P = 0.01) and increase flow (R2 = 0.62, P < 0.01). Conclusion: The arm-leg blood pressure gradient is not a reliable indicator of hemodynamic significance of restenosis in patients with prior repair of CoA. Direct visualization of collateral vessels by MRA and percent increase in flow from proximal to distal descending thoracic aorta are reliable indicators of hemodynamic significance.

Original languageEnglish (US)
Pages (from-to)177-183
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume17
Issue number2
DOIs
StatePublished - Feb 1 2003

Keywords

  • Aorta
  • Coarctation
  • Collateral circulation
  • Flow measurements
  • Magnetic resonance angiography
  • Post-operative

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'MR findings of collateral circulation are more accurate measures of hemodynamic significance than arm-leg blood pressure gradient after repair of coarctation of the aorta'. Together they form a unique fingerprint.

Cite this