Monte carlo model of stricture formation in esophageal photodynamic therapy

Norris W. Preyer, Linda R. Jones, Daryl M. Reynolds, Herbert C. Wolfsen, Michael B. Wallace

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A Monte Carlo simulation was developed for esophageal PDT. It was tested on a photosensitized pig esophagus model and compared to a published account of stricture formation in pigs. The simulation correctly predicted the damage.

Original languageEnglish (US)
Title of host publicationBiomedical Optics, BIOMED 2008
StatePublished - 2008
EventBiomedical Optics, BIOMED 2008 - St. Petersburg, FL, United States
Duration: Mar 16 2008Mar 19 2008

Other

OtherBiomedical Optics, BIOMED 2008
CountryUnited States
CitySt. Petersburg, FL
Period3/16/083/19/08

Fingerprint

Photodynamic therapy
swine
therapy
esophagus
simulation
damage
Monte Carlo simulation
1-phenyl-3,3-dimethyltriazene

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials
  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics

Cite this

Preyer, N. W., Jones, L. R., Reynolds, D. M., Wolfsen, H. C., & Wallace, M. B. (2008). Monte carlo model of stricture formation in esophageal photodynamic therapy. In Biomedical Optics, BIOMED 2008

Monte carlo model of stricture formation in esophageal photodynamic therapy. / Preyer, Norris W.; Jones, Linda R.; Reynolds, Daryl M.; Wolfsen, Herbert C.; Wallace, Michael B.

Biomedical Optics, BIOMED 2008. 2008.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Preyer, NW, Jones, LR, Reynolds, DM, Wolfsen, HC & Wallace, MB 2008, Monte carlo model of stricture formation in esophageal photodynamic therapy. in Biomedical Optics, BIOMED 2008. Biomedical Optics, BIOMED 2008, St. Petersburg, FL, United States, 3/16/08.
Preyer NW, Jones LR, Reynolds DM, Wolfsen HC, Wallace MB. Monte carlo model of stricture formation in esophageal photodynamic therapy. In Biomedical Optics, BIOMED 2008. 2008
Preyer, Norris W. ; Jones, Linda R. ; Reynolds, Daryl M. ; Wolfsen, Herbert C. ; Wallace, Michael B. / Monte carlo model of stricture formation in esophageal photodynamic therapy. Biomedical Optics, BIOMED 2008. 2008.
@inproceedings{de297756d9344e3caa1d4a82983c89dd,
title = "Monte carlo model of stricture formation in esophageal photodynamic therapy",
abstract = "A Monte Carlo simulation was developed for esophageal PDT. It was tested on a photosensitized pig esophagus model and compared to a published account of stricture formation in pigs. The simulation correctly predicted the damage.",
author = "Preyer, {Norris W.} and Jones, {Linda R.} and Reynolds, {Daryl M.} and Wolfsen, {Herbert C.} and Wallace, {Michael B.}",
year = "2008",
language = "English (US)",
booktitle = "Biomedical Optics, BIOMED 2008",

}

TY - GEN

T1 - Monte carlo model of stricture formation in esophageal photodynamic therapy

AU - Preyer, Norris W.

AU - Jones, Linda R.

AU - Reynolds, Daryl M.

AU - Wolfsen, Herbert C.

AU - Wallace, Michael B.

PY - 2008

Y1 - 2008

N2 - A Monte Carlo simulation was developed for esophageal PDT. It was tested on a photosensitized pig esophagus model and compared to a published account of stricture formation in pigs. The simulation correctly predicted the damage.

AB - A Monte Carlo simulation was developed for esophageal PDT. It was tested on a photosensitized pig esophagus model and compared to a published account of stricture formation in pigs. The simulation correctly predicted the damage.

UR - http://www.scopus.com/inward/record.url?scp=84884310605&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84884310605&partnerID=8YFLogxK

M3 - Conference contribution

BT - Biomedical Optics, BIOMED 2008

ER -