TY - JOUR
T1 - Minimally invasive epicardial implantable cardioverter-defibrillator placement for infants and children
T2 - An effective alternative to the transvenous approach
AU - Schneider, Andrew E.
AU - Burkhart, Harold M.
AU - Ackerman, Michael John
AU - Dearani, Joseph A.
AU - Wackel, Philip
AU - Cannon, Bryan C.
PY - 2016
Y1 - 2016
N2 - Background: Young patients have high rates of implantable cardioverter-defibrillator (ICD) lead fractures and are at risk for venous occlusion or tricuspid regurgitation with transvenous lead placement. Epicardial ICDs have the potential to circumvent complications associated with transvenous ICDs, but the literature on young patients remains limited. Objective: The purpose of this study was to evaluate the results of a minimally invasive epicardial ICD lead placement approach in young patients. Methods: A retrospective, institutional review board-approved electronic medical record review of all patients undergoing epicardial ICD placement at our institution from January 2011 to December 2015 was performed. Results: A total of 46 patients (20 female [43%]; mean age 10.3 years, range 0.7-18.2 years; mean weight 41 ± 21 kg) were identified; 24 (52%) were ≤10 years old. A minithoracotomy was used in 28 patients (61%). All had acceptable defibrillation, right ventricular sensing, and stimulation thresholds. Median follow-up was 2.0 ± 1.3 years (range 0.02-4.5 years). Eight surgical complications occurred in 7 patients (15%), and 8 device-related complications occurred in 6 patients (13%). Fifty-eight appropriate shocks were delivered in 7 patients (15%). Four patients received inappropriate shocks in relation to lead fractures/microfractures. One patient in this cohort who had long QT syndrome type 8 died of a hypoglycemic seizure. Conclusion: Minimally invasive epicardial ICD placement provides an effective, alternative method for implanting an ICD system, particularly in very young patients (<6 years of age) or patients who are concerned about cosmetic appearance. This technique is an acceptable alternative to traditional transvenous ICD placement.
AB - Background: Young patients have high rates of implantable cardioverter-defibrillator (ICD) lead fractures and are at risk for venous occlusion or tricuspid regurgitation with transvenous lead placement. Epicardial ICDs have the potential to circumvent complications associated with transvenous ICDs, but the literature on young patients remains limited. Objective: The purpose of this study was to evaluate the results of a minimally invasive epicardial ICD lead placement approach in young patients. Methods: A retrospective, institutional review board-approved electronic medical record review of all patients undergoing epicardial ICD placement at our institution from January 2011 to December 2015 was performed. Results: A total of 46 patients (20 female [43%]; mean age 10.3 years, range 0.7-18.2 years; mean weight 41 ± 21 kg) were identified; 24 (52%) were ≤10 years old. A minithoracotomy was used in 28 patients (61%). All had acceptable defibrillation, right ventricular sensing, and stimulation thresholds. Median follow-up was 2.0 ± 1.3 years (range 0.02-4.5 years). Eight surgical complications occurred in 7 patients (15%), and 8 device-related complications occurred in 6 patients (13%). Fifty-eight appropriate shocks were delivered in 7 patients (15%). Four patients received inappropriate shocks in relation to lead fractures/microfractures. One patient in this cohort who had long QT syndrome type 8 died of a hypoglycemic seizure. Conclusion: Minimally invasive epicardial ICD placement provides an effective, alternative method for implanting an ICD system, particularly in very young patients (<6 years of age) or patients who are concerned about cosmetic appearance. This technique is an acceptable alternative to traditional transvenous ICD placement.
KW - Epicardial ICD placement
KW - Hypertrophic cardiomyopathy
KW - Implantable cardioverter-defibrillator
KW - Long QT syndrome
KW - Minimally invasive surgical approach
UR - http://www.scopus.com/inward/record.url?scp=84979780500&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84979780500&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2016.06.024
DO - 10.1016/j.hrthm.2016.06.024
M3 - Article
C2 - 27321244
AN - SCOPUS:84979780500
SN - 1547-5271
JO - Heart Rhythm
JF - Heart Rhythm