T1 - Mechanical ventilation and the total artificial heart
T2 - Optimal ventilator trigger to avoid post-operative autocycling - a case series and literature review
AU - Shoham, Allen B.
AU - Patel, Bhavesh
AU - Arabia, Francisco A.
AU - Murray, Michael J.
PY - 2010/5/17
Y1 - 2010/5/17
N2 - Many patients with end-stage cardiomyopathy are now being implanted with Total Artificial Hearts (TAHs). We have observed individual cases of post-operative mechanical ventilator autocycling with a flow trigger, and subsequent loss of autocycling after switching to a pressure trigger. These observations prompted us to do a retrospective review of all TAH devices placed at our institution between August 2007 and May 2009. We found that in the immediate post-operative period following TAH placement, autocycling was present in 50% (5/10) of cases. There was immediate cessation of autocycling in all patients after being changed from a flow trigger of 2 L/minute to a pressure trigger of 2 cm H 2 O. The autocycling group was found to have significantly higher CVP values than the non-autocycling group (P = 0.012). Our data suggest that mechanical ventilator autocycling may be resolved or prevented by the use of a pressure trigger rather than a flow trigger setting in patients with TAHs who require mechanical ventilation.
AB - Many patients with end-stage cardiomyopathy are now being implanted with Total Artificial Hearts (TAHs). We have observed individual cases of post-operative mechanical ventilator autocycling with a flow trigger, and subsequent loss of autocycling after switching to a pressure trigger. These observations prompted us to do a retrospective review of all TAH devices placed at our institution between August 2007 and May 2009. We found that in the immediate post-operative period following TAH placement, autocycling was present in 50% (5/10) of cases. There was immediate cessation of autocycling in all patients after being changed from a flow trigger of 2 L/minute to a pressure trigger of 2 cm H 2 O. The autocycling group was found to have significantly higher CVP values than the non-autocycling group (P = 0.012). Our data suggest that mechanical ventilator autocycling may be resolved or prevented by the use of a pressure trigger rather than a flow trigger setting in patients with TAHs who require mechanical ventilation.
UR - http://www.scopus.com/inward/record.url?scp=77952215996&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77952215996&partnerID=8YFLogxK
U2 - 10.1186/1749-8090-5-39
DO - 10.1186/1749-8090-5-39
M3 - Article
C2 - 20478064
AN - SCOPUS:77952215996
SN - 1749-8090
VL - 5
JO - Journal of Cardiothoracic Surgery
JF - Journal of Cardiothoracic Surgery
IS - 1
M1 - 39
ER -