Mechanical transient-based magnetic resonance elastography

Paul J. McCracken, Armando Manduca, Joel Felmlee, Richard Lorne Ehman

Research output: Contribution to journalArticle

121 Citations (Scopus)

Abstract

Magnetic resonance elastography (MRE) is a technique for quantifying material properties by measuring cyclic displacements of propagating shear waves. As an alternative to dynamic harmonic wave MRE or quasi-steady-state methods, the idea of using a transient impulse for mechanical excitation is introduced. Two processing methods to calculate shear stiffness from transient data were developed. The techniques were tested in phantom studies, and the transient results were found to be comparable to the harmonic wave results. Transient wave based analysis was applied to the brains of six healthy volunteers in order to assess the method in areas of complex wave patterns and geometry. The results demonstrated the feasibility of measuring brain stiffness in vivo using a transient mechanical excitation. Transient and harmonic methods both measure white matter (∼12 kPa) to be stiffer than gray matter (∼8 kPa). There were some anatomic differences between harmonic and transient MRE, specifically where the transient results better depicted the deeper structures of the brain.

Original languageEnglish (US)
Pages (from-to)628-639
Number of pages12
JournalMagnetic Resonance in Medicine
Volume53
Issue number3
DOIs
StatePublished - Mar 2005

Fingerprint

Elasticity Imaging Techniques
Brain
Healthy Volunteers

Keywords

  • Brain
  • Elasticity
  • Elastography
  • Magnetic resonance imaging
  • Mechanical properties

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Mechanical transient-based magnetic resonance elastography. / McCracken, Paul J.; Manduca, Armando; Felmlee, Joel; Ehman, Richard Lorne.

In: Magnetic Resonance in Medicine, Vol. 53, No. 3, 03.2005, p. 628-639.

Research output: Contribution to journalArticle

@article{36b38ec44a95447dad5d6d9fe4894380,
title = "Mechanical transient-based magnetic resonance elastography",
abstract = "Magnetic resonance elastography (MRE) is a technique for quantifying material properties by measuring cyclic displacements of propagating shear waves. As an alternative to dynamic harmonic wave MRE or quasi-steady-state methods, the idea of using a transient impulse for mechanical excitation is introduced. Two processing methods to calculate shear stiffness from transient data were developed. The techniques were tested in phantom studies, and the transient results were found to be comparable to the harmonic wave results. Transient wave based analysis was applied to the brains of six healthy volunteers in order to assess the method in areas of complex wave patterns and geometry. The results demonstrated the feasibility of measuring brain stiffness in vivo using a transient mechanical excitation. Transient and harmonic methods both measure white matter (∼12 kPa) to be stiffer than gray matter (∼8 kPa). There were some anatomic differences between harmonic and transient MRE, specifically where the transient results better depicted the deeper structures of the brain.",
keywords = "Brain, Elasticity, Elastography, Magnetic resonance imaging, Mechanical properties",
author = "McCracken, {Paul J.} and Armando Manduca and Joel Felmlee and Ehman, {Richard Lorne}",
year = "2005",
month = "3",
doi = "10.1002/mrm.20388",
language = "English (US)",
volume = "53",
pages = "628--639",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Mechanical transient-based magnetic resonance elastography

AU - McCracken, Paul J.

AU - Manduca, Armando

AU - Felmlee, Joel

AU - Ehman, Richard Lorne

PY - 2005/3

Y1 - 2005/3

N2 - Magnetic resonance elastography (MRE) is a technique for quantifying material properties by measuring cyclic displacements of propagating shear waves. As an alternative to dynamic harmonic wave MRE or quasi-steady-state methods, the idea of using a transient impulse for mechanical excitation is introduced. Two processing methods to calculate shear stiffness from transient data were developed. The techniques were tested in phantom studies, and the transient results were found to be comparable to the harmonic wave results. Transient wave based analysis was applied to the brains of six healthy volunteers in order to assess the method in areas of complex wave patterns and geometry. The results demonstrated the feasibility of measuring brain stiffness in vivo using a transient mechanical excitation. Transient and harmonic methods both measure white matter (∼12 kPa) to be stiffer than gray matter (∼8 kPa). There were some anatomic differences between harmonic and transient MRE, specifically where the transient results better depicted the deeper structures of the brain.

AB - Magnetic resonance elastography (MRE) is a technique for quantifying material properties by measuring cyclic displacements of propagating shear waves. As an alternative to dynamic harmonic wave MRE or quasi-steady-state methods, the idea of using a transient impulse for mechanical excitation is introduced. Two processing methods to calculate shear stiffness from transient data were developed. The techniques were tested in phantom studies, and the transient results were found to be comparable to the harmonic wave results. Transient wave based analysis was applied to the brains of six healthy volunteers in order to assess the method in areas of complex wave patterns and geometry. The results demonstrated the feasibility of measuring brain stiffness in vivo using a transient mechanical excitation. Transient and harmonic methods both measure white matter (∼12 kPa) to be stiffer than gray matter (∼8 kPa). There were some anatomic differences between harmonic and transient MRE, specifically where the transient results better depicted the deeper structures of the brain.

KW - Brain

KW - Elasticity

KW - Elastography

KW - Magnetic resonance imaging

KW - Mechanical properties

UR - http://www.scopus.com/inward/record.url?scp=14744286408&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14744286408&partnerID=8YFLogxK

U2 - 10.1002/mrm.20388

DO - 10.1002/mrm.20388

M3 - Article

C2 - 15723406

AN - SCOPUS:14744286408

VL - 53

SP - 628

EP - 639

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -