Magnetization-prepared cardiac imaging using gradient echo acquisition

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Magnetization-prepared 2DFT and 3DFT gradient echo techniques are presented for acquisition of black blood cardiac images. Both methods incorporate RF pulses for blood saturation, centric or centric-like view ordering, data acquisition during late diastole, and breath-holding. In a series of 13 volunteer studies, these methods have consistently provided good visualization of intraventricular structures.

Original languageEnglish (US)
Pages (from-to)271-275
Number of pages5
JournalMagnetic Resonance in Medicine
Volume30
Issue number2
StatePublished - 1993

Fingerprint

Breath Holding
Diastole
Volunteers

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Magnetization-prepared cardiac imaging using gradient echo acquisition. / Liu, Y.; Riederer, Stephen J; Ehman, Richard Lorne.

In: Magnetic Resonance in Medicine, Vol. 30, No. 2, 1993, p. 271-275.

Research output: Contribution to journalArticle

@article{573489a99a4d4452b6f036dc67f26b03,
title = "Magnetization-prepared cardiac imaging using gradient echo acquisition",
abstract = "Magnetization-prepared 2DFT and 3DFT gradient echo techniques are presented for acquisition of black blood cardiac images. Both methods incorporate RF pulses for blood saturation, centric or centric-like view ordering, data acquisition during late diastole, and breath-holding. In a series of 13 volunteer studies, these methods have consistently provided good visualization of intraventricular structures.",
author = "Y. Liu and Riederer, {Stephen J} and Ehman, {Richard Lorne}",
year = "1993",
language = "English (US)",
volume = "30",
pages = "271--275",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Magnetization-prepared cardiac imaging using gradient echo acquisition

AU - Liu, Y.

AU - Riederer, Stephen J

AU - Ehman, Richard Lorne

PY - 1993

Y1 - 1993

N2 - Magnetization-prepared 2DFT and 3DFT gradient echo techniques are presented for acquisition of black blood cardiac images. Both methods incorporate RF pulses for blood saturation, centric or centric-like view ordering, data acquisition during late diastole, and breath-holding. In a series of 13 volunteer studies, these methods have consistently provided good visualization of intraventricular structures.

AB - Magnetization-prepared 2DFT and 3DFT gradient echo techniques are presented for acquisition of black blood cardiac images. Both methods incorporate RF pulses for blood saturation, centric or centric-like view ordering, data acquisition during late diastole, and breath-holding. In a series of 13 volunteer studies, these methods have consistently provided good visualization of intraventricular structures.

UR - http://www.scopus.com/inward/record.url?scp=0027235783&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027235783&partnerID=8YFLogxK

M3 - Article

VL - 30

SP - 271

EP - 275

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -