Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms

M. Killer, David F Kallmes, R. Jones, Y. Ding, M. Vestal, T. Hauser, R. Virmani, G. Cruise

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Background: The aim of this study was to compare the performance of a new filling coil, the HydroFill device, to historical results of HydroSoft and bare platinum coil devices in experimental rabbit aneurysms. Methods: Experimental aneurysms were constructed in rabbits and embolized with HydroFill (n=32), HydroSoft (n=48), or bare platinum coil (n=47) devices. Angiographic occlusion was evaluated post-treatment and at 1 month (n=55), 3 month (n=20), 6 month (n=35), and 12 month (n=12) follow-ups according to the Raymond scale. The aneurysms were analyzed histologically for neointima formation, thrombus organization, and inflammation. Continuous and discrete results were compared using ANOVA/t-test and X 2 tests, respectively. Results: Volumetric occlusion of the aneurysm sac was increased in the HydroFill group compared to the HydroSoft and platinum coil groups. Protrusions into the parent artery were common in all treatment groups due to the treatment of wide-necked aneurysms without the use of balloons or stents. Although angiographic occlusion post-treatment scores were reduced in the HydroFill group compared to the HydroSoft and platinum coil groups, stable/progressive occlusion was increased in the HydroFill group compared to the platinum coil group. Histologically, neointima formation and thrombus organization scores were increased in the HydroFill and HydroSoft groups compared to the platinum coil group at 3 months. Although there were some differences in the scoring, inflammation was generally minimal to mild in all three groups. Conclusion: The HydroFill device, with its high levels of volumetric filling, increased stable/progressive occlusion at follow-up, increased neointima formation, and increased thrombus organization, shows promise for clinical use.

Original languageEnglish (US)
Pages (from-to)97-105
Number of pages9
JournalMinimally Invasive Neurosurgery
Volume53
Issue number3
DOIs
StatePublished - 2010

Fingerprint

Hydrogel
Platinum
Aneurysm
Rabbits
Neointima
Equipment and Supplies
Thrombosis
Inflammation
Stents
Analysis of Variance
Arteries

Keywords

  • aneurysm
  • animal models
  • hydrogel
  • therapeutic embolization

ASJC Scopus subject areas

  • Clinical Neurology
  • Surgery

Cite this

Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms. / Killer, M.; Kallmes, David F; Jones, R.; Ding, Y.; Vestal, M.; Hauser, T.; Virmani, R.; Cruise, G.

In: Minimally Invasive Neurosurgery, Vol. 53, No. 3, 2010, p. 97-105.

Research output: Contribution to journalArticle

Killer, M. ; Kallmes, David F ; Jones, R. ; Ding, Y. ; Vestal, M. ; Hauser, T. ; Virmani, R. ; Cruise, G. / Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms. In: Minimally Invasive Neurosurgery. 2010 ; Vol. 53, No. 3. pp. 97-105.
@article{d267daf6f2b14851b366d8daa4d16e30,
title = "Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms",
abstract = "Background: The aim of this study was to compare the performance of a new filling coil, the HydroFill device, to historical results of HydroSoft and bare platinum coil devices in experimental rabbit aneurysms. Methods: Experimental aneurysms were constructed in rabbits and embolized with HydroFill (n=32), HydroSoft (n=48), or bare platinum coil (n=47) devices. Angiographic occlusion was evaluated post-treatment and at 1 month (n=55), 3 month (n=20), 6 month (n=35), and 12 month (n=12) follow-ups according to the Raymond scale. The aneurysms were analyzed histologically for neointima formation, thrombus organization, and inflammation. Continuous and discrete results were compared using ANOVA/t-test and X 2 tests, respectively. Results: Volumetric occlusion of the aneurysm sac was increased in the HydroFill group compared to the HydroSoft and platinum coil groups. Protrusions into the parent artery were common in all treatment groups due to the treatment of wide-necked aneurysms without the use of balloons or stents. Although angiographic occlusion post-treatment scores were reduced in the HydroFill group compared to the HydroSoft and platinum coil groups, stable/progressive occlusion was increased in the HydroFill group compared to the platinum coil group. Histologically, neointima formation and thrombus organization scores were increased in the HydroFill and HydroSoft groups compared to the platinum coil group at 3 months. Although there were some differences in the scoring, inflammation was generally minimal to mild in all three groups. Conclusion: The HydroFill device, with its high levels of volumetric filling, increased stable/progressive occlusion at follow-up, increased neointima formation, and increased thrombus organization, shows promise for clinical use.",
keywords = "aneurysm, animal models, hydrogel, therapeutic embolization",
author = "M. Killer and Kallmes, {David F} and R. Jones and Y. Ding and M. Vestal and T. Hauser and R. Virmani and G. Cruise",
year = "2010",
doi = "10.1055/s-0030-1252059",
language = "English (US)",
volume = "53",
pages = "97--105",
journal = "Minimally Invasive Neurosurgery",
issn = "0946-7211",
publisher = "Georg Thieme Verlag",
number = "3",

}

TY - JOUR

T1 - Long-term angiographic and histological results of a new hydrogel-containing filling coil in experimental rabbit aneurysms

AU - Killer, M.

AU - Kallmes, David F

AU - Jones, R.

AU - Ding, Y.

AU - Vestal, M.

AU - Hauser, T.

AU - Virmani, R.

AU - Cruise, G.

PY - 2010

Y1 - 2010

N2 - Background: The aim of this study was to compare the performance of a new filling coil, the HydroFill device, to historical results of HydroSoft and bare platinum coil devices in experimental rabbit aneurysms. Methods: Experimental aneurysms were constructed in rabbits and embolized with HydroFill (n=32), HydroSoft (n=48), or bare platinum coil (n=47) devices. Angiographic occlusion was evaluated post-treatment and at 1 month (n=55), 3 month (n=20), 6 month (n=35), and 12 month (n=12) follow-ups according to the Raymond scale. The aneurysms were analyzed histologically for neointima formation, thrombus organization, and inflammation. Continuous and discrete results were compared using ANOVA/t-test and X 2 tests, respectively. Results: Volumetric occlusion of the aneurysm sac was increased in the HydroFill group compared to the HydroSoft and platinum coil groups. Protrusions into the parent artery were common in all treatment groups due to the treatment of wide-necked aneurysms without the use of balloons or stents. Although angiographic occlusion post-treatment scores were reduced in the HydroFill group compared to the HydroSoft and platinum coil groups, stable/progressive occlusion was increased in the HydroFill group compared to the platinum coil group. Histologically, neointima formation and thrombus organization scores were increased in the HydroFill and HydroSoft groups compared to the platinum coil group at 3 months. Although there were some differences in the scoring, inflammation was generally minimal to mild in all three groups. Conclusion: The HydroFill device, with its high levels of volumetric filling, increased stable/progressive occlusion at follow-up, increased neointima formation, and increased thrombus organization, shows promise for clinical use.

AB - Background: The aim of this study was to compare the performance of a new filling coil, the HydroFill device, to historical results of HydroSoft and bare platinum coil devices in experimental rabbit aneurysms. Methods: Experimental aneurysms were constructed in rabbits and embolized with HydroFill (n=32), HydroSoft (n=48), or bare platinum coil (n=47) devices. Angiographic occlusion was evaluated post-treatment and at 1 month (n=55), 3 month (n=20), 6 month (n=35), and 12 month (n=12) follow-ups according to the Raymond scale. The aneurysms were analyzed histologically for neointima formation, thrombus organization, and inflammation. Continuous and discrete results were compared using ANOVA/t-test and X 2 tests, respectively. Results: Volumetric occlusion of the aneurysm sac was increased in the HydroFill group compared to the HydroSoft and platinum coil groups. Protrusions into the parent artery were common in all treatment groups due to the treatment of wide-necked aneurysms without the use of balloons or stents. Although angiographic occlusion post-treatment scores were reduced in the HydroFill group compared to the HydroSoft and platinum coil groups, stable/progressive occlusion was increased in the HydroFill group compared to the platinum coil group. Histologically, neointima formation and thrombus organization scores were increased in the HydroFill and HydroSoft groups compared to the platinum coil group at 3 months. Although there were some differences in the scoring, inflammation was generally minimal to mild in all three groups. Conclusion: The HydroFill device, with its high levels of volumetric filling, increased stable/progressive occlusion at follow-up, increased neointima formation, and increased thrombus organization, shows promise for clinical use.

KW - aneurysm

KW - animal models

KW - hydrogel

KW - therapeutic embolization

UR - http://www.scopus.com/inward/record.url?scp=77956299986&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956299986&partnerID=8YFLogxK

U2 - 10.1055/s-0030-1252059

DO - 10.1055/s-0030-1252059

M3 - Article

C2 - 20809449

AN - SCOPUS:77956299986

VL - 53

SP - 97

EP - 105

JO - Minimally Invasive Neurosurgery

JF - Minimally Invasive Neurosurgery

SN - 0946-7211

IS - 3