TY - JOUR
T1 - Localization of liver lesions in abdominal CT imaging
T2 - I. Correlation of human observer performance between anatomical and uniform backgrounds
AU - Dilger, Samantha K.N.
AU - Yu, Lifeng
AU - Chen, Baiyu
AU - Favazza, Chris P.
AU - Carter, Rickey E.
AU - Fletcher, Joel G.
AU - McCollough, Cynthia H.
AU - Leng, Shuai
N1 - Publisher Copyright:
© 2019 Institute of Physics and Engineering in Medicine.
PY - 2019/5/10
Y1 - 2019/5/10
N2 - The purpose of this study was to determine the correlation between human observer performance for localization of small low contrast lesions within uniform water background versus an anatomical liver background, under the conditions of varying dose, lesion size, and reconstruction algorithm. Liver lesions (5 mm, 7 mm, and 9 mm, contrast: -21 HU) were digitally inserted into CT projection data of ten normal patients in vessel-free liver regions. Noise was inserted into the projection data to create three image sets: full dose and simulated half and quarter doses. Images were reconstructed with a standard filtered back projection (FBP) and an iterative reconstruction (IR) algorithm. Lesion and noise insertion procedures were repeated with water phantom data. Two-dimensional regions of interest (66 lesion-present, 34 lesion-absent) were selected, randomized, and independently reviewed by three medical physicists to identify the most likely location of the lesion and provide a confidence score. Locations and confidence scores were assessed using the area under the localization receiver operating characteristic curve (AzLROC). We examined the correlation between human performance for the liver and uniform water backgrounds as dose, lesion size, and reconstruction algorithm varied. As lesion size or dose increased, reader localization performance improved. For full dose IR images, the AzLROC for 5, 7, and 9 mm lesions were 0.53, 0.91, and 0.97 (liver) and 0.51, 0.96, and 0.99 (uniform water), respectively. Similar trends were seen with other parameters. Performance values for liver and uniform backgrounds were highly correlated for both reconstruction algorithms, with a Spearman correlation of ρ = 0.97, and an average difference in AzLROC of 0.05 ± 0.04. For the task of localizing low contrast liver lesions, human observer performance was highly correlated between anatomical and uniform backgrounds, suggesting that lesion localization studies emulating a clinical test of liver lesion detection can be performed using a uniform background.
AB - The purpose of this study was to determine the correlation between human observer performance for localization of small low contrast lesions within uniform water background versus an anatomical liver background, under the conditions of varying dose, lesion size, and reconstruction algorithm. Liver lesions (5 mm, 7 mm, and 9 mm, contrast: -21 HU) were digitally inserted into CT projection data of ten normal patients in vessel-free liver regions. Noise was inserted into the projection data to create three image sets: full dose and simulated half and quarter doses. Images were reconstructed with a standard filtered back projection (FBP) and an iterative reconstruction (IR) algorithm. Lesion and noise insertion procedures were repeated with water phantom data. Two-dimensional regions of interest (66 lesion-present, 34 lesion-absent) were selected, randomized, and independently reviewed by three medical physicists to identify the most likely location of the lesion and provide a confidence score. Locations and confidence scores were assessed using the area under the localization receiver operating characteristic curve (AzLROC). We examined the correlation between human performance for the liver and uniform water backgrounds as dose, lesion size, and reconstruction algorithm varied. As lesion size or dose increased, reader localization performance improved. For full dose IR images, the AzLROC for 5, 7, and 9 mm lesions were 0.53, 0.91, and 0.97 (liver) and 0.51, 0.96, and 0.99 (uniform water), respectively. Similar trends were seen with other parameters. Performance values for liver and uniform backgrounds were highly correlated for both reconstruction algorithms, with a Spearman correlation of ρ = 0.97, and an average difference in AzLROC of 0.05 ± 0.04. For the task of localizing low contrast liver lesions, human observer performance was highly correlated between anatomical and uniform backgrounds, suggesting that lesion localization studies emulating a clinical test of liver lesion detection can be performed using a uniform background.
KW - comparison study
KW - computed tomography (CT)
KW - image quality
KW - iterative reconstruction (IR)
KW - lesion localization
KW - low contrast detectability
KW - radiation dose
UR - http://www.scopus.com/inward/record.url?scp=85066002426&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85066002426&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/ab1a45
DO - 10.1088/1361-6560/ab1a45
M3 - Article
C2 - 30995611
AN - SCOPUS:85066002426
VL - 64
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
SN - 0031-9155
IS - 10
M1 - 105011
ER -