T1 - Left ventricular systolic dysfunction identification using artificial intelligence-augmented electrocardiogram in cardiac intensive care unit patients
AU - Jentzer, Jacob C.
AU - Kashou, Anthony H.
AU - Attia, Zachi I.
AU - Lopez-Jimenez, Francisco
AU - Kapa, Suraj
AU - Friedman, Paul A.
AU - Noseworthy, Peter A.
N1 - Publisher Copyright:
© 2020 Elsevier B.V.
PY - 2021/3/1
Y1 - 2021/3/1
N2 - Background: An artificial intelligence-augmented electrocardiogram (AI-ECG) can identify left ventricular systolic dysfunction (LVSD). We examined the accuracy of AI ECG for identification of LVSD (defined as LVEF ≤40% by transthoracic echocardiogram [TTE]) in cardiac intensive care unit (CICU) patients. Method: We included unique Mayo Clinic CICU patients admitted from 2007 to 2018 who underwent AI-ECG and TTE within 7 days, at least one of which was during hospitalization. Discrimination of the AI-ECG for LVSD was determined using receiver-operator characteristic curve (AUC) values. Results: We included 5680 patients with a mean age of 68 ± 15 years (37% females). Acute coronary syndrome (ACS) was present in 55%. LVSD was present in 34% of patients (mean LVEF 48 ± 16%). The AI-ECG had an AUC of 0.83 (95% confidence interval 0.82–0.84) for discrimination of LVSD. Using the optimal cut-off, the AI-ECG had 73%, specificity 78%, negative predictive value 85% and overall accuracy 76% for LVSD. AUC values were higher for patients aged <70 years (0.85 versus 0.80), males (0.84 versus 0.79), patients without ACS (0.86 versus 0.80), and patients who did not undergo revascularization (0.84 versus 0.80). Conclusions: The AI-ECG algorithm had very good discrimination for LVSD in this critically-ill CICU cohort with a high prevalence of LVSD. Performance was better in younger male patients and those without ACS, highlighting those CICU patients in whom screening for LVSD using AI ECG may be more effective. The AI-ECG might potentially be useful for identification of LVSD in resource-limited settings when TTE is unavailable.
AB - Background: An artificial intelligence-augmented electrocardiogram (AI-ECG) can identify left ventricular systolic dysfunction (LVSD). We examined the accuracy of AI ECG for identification of LVSD (defined as LVEF ≤40% by transthoracic echocardiogram [TTE]) in cardiac intensive care unit (CICU) patients. Method: We included unique Mayo Clinic CICU patients admitted from 2007 to 2018 who underwent AI-ECG and TTE within 7 days, at least one of which was during hospitalization. Discrimination of the AI-ECG for LVSD was determined using receiver-operator characteristic curve (AUC) values. Results: We included 5680 patients with a mean age of 68 ± 15 years (37% females). Acute coronary syndrome (ACS) was present in 55%. LVSD was present in 34% of patients (mean LVEF 48 ± 16%). The AI-ECG had an AUC of 0.83 (95% confidence interval 0.82–0.84) for discrimination of LVSD. Using the optimal cut-off, the AI-ECG had 73%, specificity 78%, negative predictive value 85% and overall accuracy 76% for LVSD. AUC values were higher for patients aged <70 years (0.85 versus 0.80), males (0.84 versus 0.79), patients without ACS (0.86 versus 0.80), and patients who did not undergo revascularization (0.84 versus 0.80). Conclusions: The AI-ECG algorithm had very good discrimination for LVSD in this critically-ill CICU cohort with a high prevalence of LVSD. Performance was better in younger male patients and those without ACS, highlighting those CICU patients in whom screening for LVSD using AI ECG may be more effective. The AI-ECG might potentially be useful for identification of LVSD in resource-limited settings when TTE is unavailable.
KW - Artificial intelligence
KW - Cardiac intensive care unit
KW - Echocardiography
KW - Electrocardiogram
KW - Left ventricular dysfunction
UR - http://www.scopus.com/inward/record.url?scp=85095723648&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85095723648&partnerID=8YFLogxK
U2 - 10.1016/j.ijcard.2020.10.074
DO - 10.1016/j.ijcard.2020.10.074
M3 - Article
C2 - 33152415
AN - SCOPUS:85095723648
SN - 0167-5273
VL - 326
SP - 114
EP - 123
JO - International Journal of Cardiology
JF - International Journal of Cardiology
ER -