TY - JOUR
T1 - Left ventricular assist device outcomes based on flow configuration and pre-operative left ventricular dimension
T2 - An Interagency Registry for Mechanically Assisted Circulatory Support Analysis
AU - Shah, Palak
AU - Birk, Sarah
AU - Maltais, Simon
AU - Stulak, John
AU - Elmi, Angelo
AU - Pagani, Francis D.
AU - Cowger, Jennifer A.
N1 - Publisher Copyright:
© 2017 International Society for Heart and Lung Transplantation
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2017/6
Y1 - 2017/6
N2 - Background Axial configuration (AC) and centrifugal configuration (CC) left ventricular assist devices (LVAD) have different flow characteristics, and whether the interaction between device flow configuration and the pre-operative left ventricular internal diastolic diameter (LVIDD) mediates adverse events after LVAD implantation is unknown. Methods We queried 9,424 continuous-flow LVAD recipients who received LVADs from April 2008 to June of 2015 in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). The pre-operative LVIDD * flow configuration interaction term was tested in multivariable models to determine its relationship to adverse events. Results The pre-operative LVIDD * flow configuration interaction was a significant predictor of device thrombosis. As the LVIDD increased, the risk of AC device thrombosis increased compared with CC devices (p = 0.0099). At 7.0 cm, the hazard ratio (HR) for AC device thrombosis compared with the CC device was 1.61 (95% confidence interval [CI], 1.17–2.22; p = 0.004) and continued to rise as the LVIDD increased. The LVIDD * flow configuration interaction did not predict stroke, gastrointestinal bleeding, or patient survival. In multivariable models, the hazard of stroke was higher with the CC device regardless of the LVIDD (HR, 1.96; 95% CI, 1.64–2.36; p < 0.0001). Adjusted analyses showed LVAD implantation into a larger left ventricle was associated with a lower risk of death (HR, 0.90; 95% CI, 0.85–0.95; p = 0.0004) per centimeter of LVIDD. Conclusions Our study suggests that the pre-operative LVIDD, flow configuration, and interaction terms should be considered individually when choosing the appropriate LVAD to mitigate the rates of device thrombosis, stroke, and death.
AB - Background Axial configuration (AC) and centrifugal configuration (CC) left ventricular assist devices (LVAD) have different flow characteristics, and whether the interaction between device flow configuration and the pre-operative left ventricular internal diastolic diameter (LVIDD) mediates adverse events after LVAD implantation is unknown. Methods We queried 9,424 continuous-flow LVAD recipients who received LVADs from April 2008 to June of 2015 in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). The pre-operative LVIDD * flow configuration interaction term was tested in multivariable models to determine its relationship to adverse events. Results The pre-operative LVIDD * flow configuration interaction was a significant predictor of device thrombosis. As the LVIDD increased, the risk of AC device thrombosis increased compared with CC devices (p = 0.0099). At 7.0 cm, the hazard ratio (HR) for AC device thrombosis compared with the CC device was 1.61 (95% confidence interval [CI], 1.17–2.22; p = 0.004) and continued to rise as the LVIDD increased. The LVIDD * flow configuration interaction did not predict stroke, gastrointestinal bleeding, or patient survival. In multivariable models, the hazard of stroke was higher with the CC device regardless of the LVIDD (HR, 1.96; 95% CI, 1.64–2.36; p < 0.0001). Adjusted analyses showed LVAD implantation into a larger left ventricle was associated with a lower risk of death (HR, 0.90; 95% CI, 0.85–0.95; p = 0.0004) per centimeter of LVIDD. Conclusions Our study suggests that the pre-operative LVIDD, flow configuration, and interaction terms should be considered individually when choosing the appropriate LVAD to mitigate the rates of device thrombosis, stroke, and death.
KW - LVAD
KW - adverse events
KW - axial-flow
KW - centrifugal-flow
KW - left ventricular size
UR - http://www.scopus.com/inward/record.url?scp=85009224966&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85009224966&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2016.12.004
DO - 10.1016/j.healun.2016.12.004
M3 - Article
C2 - 28087105
AN - SCOPUS:85009224966
SN - 1053-2498
VL - 36
SP - 640
EP - 649
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 6
ER -