TY - JOUR
T1 - “Large Diameter” Aortic Endografts are Associated With Aneurysm Sac Expansion
AU - Lu, Patricia G.
AU - Erben, Young
AU - Sheaffer, William W.
AU - Pierce, Austin T.
AU - Mendes, Bernardo
AU - DeMartino, Randall
AU - Stone, William
AU - Davila, Victor J.
AU - Soh, Ina Y.
AU - Meltzer, Andrew J.
N1 - Publisher Copyright:
© 2022 Elsevier Inc.
PY - 2022/11
Y1 - 2022/11
N2 - Background: The purpose of this study was to evaluate the association between aortic endograft diameter and long-term outcomes following endovascular aneurysm repair (EVAR) performed in accordance with manufacturer instructions for use (IFU). Methods: A retrospective review of consecutive patients undergoing on-IFU EVAR (2000–2018) was performed to facilitate a comparative analysis of long-term patient outcomes based on device diameter. “Large diameter” devices were defined as >34 mm. The primary outcome of interest was freedom from sac expansion throughout long-term follow-up. Analyses included standard bivariate analyses, Kaplan–Meier with log-rank comparison, and Cox proportional hazards multivariate analysis. Results: A total of 1,099 underwent on-IFU EVAR from 2000–2018. Follow-up data were available for 980 patients. Of these, 75 patients (7.6%) were treated with >34-mm devices. There were no significant differences in demographics or comorbidities between the 2 groups, although preoperative abdominal aortic aneurysm size was greater in patients undergoing implantation of >34-mm devices (58 ± 8.5 mm vs. 56 ± 17.4 mm; P = 0.05). Median follow-up was 10.3 years. Patients with grafts >34 mm had reduced freedom from sac expansion throughout follow-up (P = 0.038). There were no significant differences in reintervention rates, open conversion, or rupture when stratified by graft diameter. A multivariate Cox regression identified patient age, preoperative abdominal aortic aneurysm size, need for reintervention, and use of >34-mm endografts as independent factors associated with expansion. Conclusions: The use of large diameter aortic endografts is associated with higher rates of sac expansion during long-term follow-up. Although there is undoubtedly a role for large diameter graft use in selected patients, it is important to recognize that these devices were typically approved post hoc without the same regulatory scrutiny of smaller endografts. These findings underscore the importance of ongoing surveillance for patients treated with >34-mm grafts, irrespective of compliance with manufacturer IFU.
AB - Background: The purpose of this study was to evaluate the association between aortic endograft diameter and long-term outcomes following endovascular aneurysm repair (EVAR) performed in accordance with manufacturer instructions for use (IFU). Methods: A retrospective review of consecutive patients undergoing on-IFU EVAR (2000–2018) was performed to facilitate a comparative analysis of long-term patient outcomes based on device diameter. “Large diameter” devices were defined as >34 mm. The primary outcome of interest was freedom from sac expansion throughout long-term follow-up. Analyses included standard bivariate analyses, Kaplan–Meier with log-rank comparison, and Cox proportional hazards multivariate analysis. Results: A total of 1,099 underwent on-IFU EVAR from 2000–2018. Follow-up data were available for 980 patients. Of these, 75 patients (7.6%) were treated with >34-mm devices. There were no significant differences in demographics or comorbidities between the 2 groups, although preoperative abdominal aortic aneurysm size was greater in patients undergoing implantation of >34-mm devices (58 ± 8.5 mm vs. 56 ± 17.4 mm; P = 0.05). Median follow-up was 10.3 years. Patients with grafts >34 mm had reduced freedom from sac expansion throughout follow-up (P = 0.038). There were no significant differences in reintervention rates, open conversion, or rupture when stratified by graft diameter. A multivariate Cox regression identified patient age, preoperative abdominal aortic aneurysm size, need for reintervention, and use of >34-mm endografts as independent factors associated with expansion. Conclusions: The use of large diameter aortic endografts is associated with higher rates of sac expansion during long-term follow-up. Although there is undoubtedly a role for large diameter graft use in selected patients, it is important to recognize that these devices were typically approved post hoc without the same regulatory scrutiny of smaller endografts. These findings underscore the importance of ongoing surveillance for patients treated with >34-mm grafts, irrespective of compliance with manufacturer IFU.
UR - http://www.scopus.com/inward/record.url?scp=85132720518&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85132720518&partnerID=8YFLogxK
U2 - 10.1016/j.avsg.2022.04.046
DO - 10.1016/j.avsg.2022.04.046
M3 - Article
C2 - 35595204
AN - SCOPUS:85132720518
SN - 0890-5096
VL - 87
SP - 225
EP - 230
JO - Annals of Vascular Surgery
JF - Annals of Vascular Surgery
ER -