TY - JOUR
T1 - Kalman Filter-Based Microbubble Tracking for Robust Super-Resolution Ultrasound Microvessel Imaging
AU - Tang, Shanshan
AU - Song, Pengfei
AU - Trzasko, Joshua D.
AU - Lowerison, Matthew
AU - Huang, Chengwu
AU - Gong, Ping
AU - Lok, U. Wai
AU - Manduca, Armando
AU - Chen, Shigao
N1 - Funding Information:
Manuscript received January 31, 2020; accepted March 25, 2020. Date of publication March 31, 2020; date of current version August 27, 2020. This work was supported in part by the National Institutes of Health (NIH) under Grant R01NS111039, Grant R03EB027742, Grant R00CA214523, Grant K99CA214523, and Grant R01DK120559. (Shanshan Tang and Pengfei Song contributed equally to this work.) (Corresponding author: Shigao Chen.) Shanshan Tang, Joshua D. Trzasko, Chengwu Huang, Ping Gong, U-Wai Lok, and Shigao Chen are with the Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN 55905 USA (e-mail: chen.shigao@mayo.edu).
Publisher Copyright:
© 1986-2012 IEEE.
PY - 2020/9
Y1 - 2020/9
N2 - Contrast microbubble (MB)-based super-resolution ultrasound microvessel imaging (SR-UMI) overcomes the compromise in conventional ultrasound imaging between spatial resolution and penetration depth and has been successfully applied to a wide range of clinical applications. However, clinical translation of SR-UMI remains challenging due to the limited number of MBs detected within a given accumulation time. Here, we propose a Kalman filter-based method for robust MB tracking and improved blood flow speed measurement with reduced numbers of MBs. An acceleration constraint and a direction constraint for MB movement were developed to control the quality of the estimated MB trajectory. An adaptive interpolation approach was developed to inpaint the missing microvessel signal based on the estimated local blood flow speed, facilitating more robust depiction of microvasculature with a limited amount of MBs. The proposed method was validated on an ex ovo chorioallantoic membrane and an in vivo rabbit kidney. Results demonstrated improved imaging performance on both microvessel density maps and blood flow speed maps. With the proposed method, the percentage of microvessel filling in a selected blood vessel at a given accumulation period was increased from 28.17% to 74.45%. A similar SR-UMI performance was achieved with MB numbers reduced by 85.96%, compared to that with the original MB number. The results indicate that the proposed method substantially improves the robustness of SR-UMI under a clinically relevant imaging scenario where SR-UMI is challenged by a limited MB accumulation time, reduced number of MBs, lowered imaging frame rate, and degraded signal-to-noise ratio.
AB - Contrast microbubble (MB)-based super-resolution ultrasound microvessel imaging (SR-UMI) overcomes the compromise in conventional ultrasound imaging between spatial resolution and penetration depth and has been successfully applied to a wide range of clinical applications. However, clinical translation of SR-UMI remains challenging due to the limited number of MBs detected within a given accumulation time. Here, we propose a Kalman filter-based method for robust MB tracking and improved blood flow speed measurement with reduced numbers of MBs. An acceleration constraint and a direction constraint for MB movement were developed to control the quality of the estimated MB trajectory. An adaptive interpolation approach was developed to inpaint the missing microvessel signal based on the estimated local blood flow speed, facilitating more robust depiction of microvasculature with a limited amount of MBs. The proposed method was validated on an ex ovo chorioallantoic membrane and an in vivo rabbit kidney. Results demonstrated improved imaging performance on both microvessel density maps and blood flow speed maps. With the proposed method, the percentage of microvessel filling in a selected blood vessel at a given accumulation period was increased from 28.17% to 74.45%. A similar SR-UMI performance was achieved with MB numbers reduced by 85.96%, compared to that with the original MB number. The results indicate that the proposed method substantially improves the robustness of SR-UMI under a clinically relevant imaging scenario where SR-UMI is challenged by a limited MB accumulation time, reduced number of MBs, lowered imaging frame rate, and degraded signal-to-noise ratio.
KW - Kalman filter
KW - microbubble (MB) tracking
KW - microvasculature
KW - super-resolution
KW - ultrasound microvessel imaging
UR - http://www.scopus.com/inward/record.url?scp=85083273764&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85083273764&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2020.2984384
DO - 10.1109/TUFFC.2020.2984384
M3 - Article
C2 - 32248099
AN - SCOPUS:85083273764
SN - 0885-3010
VL - 67
SP - 1738
EP - 1751
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 9
M1 - 9051656
ER -