Is there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary study

O. Cirpar, O. K. Arikan, Ayse Tuba Kendi, Orhan Görgülü

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Objectives: To investigate the possible association between chronic noise-induced hearing loss and the volume of mastoid pneumatization. Methodology: The study involved 46 subjects employed in the press and montage department of a gun factory: 28 in the study group with noise-induced hearing loss and 18 in the control group with no hearing loss. The volume of mastoid pneumatization was measured with computed tomography. Student's t test was used in the comparison of the mastoid volumes of the study and the control groups. Results: The intergroup evaluations showed no significant difference between the study and control group with regards to age, use of substances or ototoxic drugs, systemic diseases, use of personal hearing protectors, duration of occupational and non-occupational noise exposure was observed (P > 0.05). The mean values of mastoid pneumatization in the study and the control groups were 9717.6 mm3 and 11005.8 mm3, respectively. Although the volume of mastoid pneumatization was smaller in the study group than in the control group, this difference was not statistically significant (P > 0.05). Conclusions: This preliminary study showed that there was no significant correlation between mastoid pneumatization volume and chronic noise-induced hearing loss. However, this correlation could be significant in further studies with a larger number of subjects.

Original languageEnglish (US)
Pages (from-to)241-245
Number of pages5
JournalB-ENT
Volume8
Issue number4
StatePublished - Dec 1 2012
Externally publishedYes

Fingerprint

Noise-Induced Hearing Loss
Mastoid
Control Groups
Firearms
Hearing Loss
Hearing
Noise
Tomography
Students
Pharmaceutical Preparations

Keywords

  • Computed tomography
  • Hearing loss
  • Mastoid aeration
  • Noise-induced hearing loss
  • Occupational hearing loss

ASJC Scopus subject areas

  • Otorhinolaryngology

Cite this

Is there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary study. / Cirpar, O.; Arikan, O. K.; Tuba Kendi, Ayse; Görgülü, Orhan.

In: B-ENT, Vol. 8, No. 4, 01.12.2012, p. 241-245.

Research output: Contribution to journalArticle

@article{0f44b98e8ad4457381d2611d570caa1f,
title = "Is there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary study",
abstract = "Objectives: To investigate the possible association between chronic noise-induced hearing loss and the volume of mastoid pneumatization. Methodology: The study involved 46 subjects employed in the press and montage department of a gun factory: 28 in the study group with noise-induced hearing loss and 18 in the control group with no hearing loss. The volume of mastoid pneumatization was measured with computed tomography. Student's t test was used in the comparison of the mastoid volumes of the study and the control groups. Results: The intergroup evaluations showed no significant difference between the study and control group with regards to age, use of substances or ototoxic drugs, systemic diseases, use of personal hearing protectors, duration of occupational and non-occupational noise exposure was observed (P > 0.05). The mean values of mastoid pneumatization in the study and the control groups were 9717.6 mm3 and 11005.8 mm3, respectively. Although the volume of mastoid pneumatization was smaller in the study group than in the control group, this difference was not statistically significant (P > 0.05). Conclusions: This preliminary study showed that there was no significant correlation between mastoid pneumatization volume and chronic noise-induced hearing loss. However, this correlation could be significant in further studies with a larger number of subjects.",
keywords = "Computed tomography, Hearing loss, Mastoid aeration, Noise-induced hearing loss, Occupational hearing loss",
author = "O. Cirpar and Arikan, {O. K.} and {Tuba Kendi}, Ayse and Orhan G{\"o}rg{\"u}l{\"u}",
year = "2012",
month = "12",
day = "1",
language = "English (US)",
volume = "8",
pages = "241--245",
journal = "B-ENT",
issn = "1781-782X",
publisher = "Koninklijke Belgische Vereniging voor ORL Gelaat en Halschirugie",
number = "4",

}

TY - JOUR

T1 - Is there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary study

AU - Cirpar, O.

AU - Arikan, O. K.

AU - Tuba Kendi, Ayse

AU - Görgülü, Orhan

PY - 2012/12/1

Y1 - 2012/12/1

N2 - Objectives: To investigate the possible association between chronic noise-induced hearing loss and the volume of mastoid pneumatization. Methodology: The study involved 46 subjects employed in the press and montage department of a gun factory: 28 in the study group with noise-induced hearing loss and 18 in the control group with no hearing loss. The volume of mastoid pneumatization was measured with computed tomography. Student's t test was used in the comparison of the mastoid volumes of the study and the control groups. Results: The intergroup evaluations showed no significant difference between the study and control group with regards to age, use of substances or ototoxic drugs, systemic diseases, use of personal hearing protectors, duration of occupational and non-occupational noise exposure was observed (P > 0.05). The mean values of mastoid pneumatization in the study and the control groups were 9717.6 mm3 and 11005.8 mm3, respectively. Although the volume of mastoid pneumatization was smaller in the study group than in the control group, this difference was not statistically significant (P > 0.05). Conclusions: This preliminary study showed that there was no significant correlation between mastoid pneumatization volume and chronic noise-induced hearing loss. However, this correlation could be significant in further studies with a larger number of subjects.

AB - Objectives: To investigate the possible association between chronic noise-induced hearing loss and the volume of mastoid pneumatization. Methodology: The study involved 46 subjects employed in the press and montage department of a gun factory: 28 in the study group with noise-induced hearing loss and 18 in the control group with no hearing loss. The volume of mastoid pneumatization was measured with computed tomography. Student's t test was used in the comparison of the mastoid volumes of the study and the control groups. Results: The intergroup evaluations showed no significant difference between the study and control group with regards to age, use of substances or ototoxic drugs, systemic diseases, use of personal hearing protectors, duration of occupational and non-occupational noise exposure was observed (P > 0.05). The mean values of mastoid pneumatization in the study and the control groups were 9717.6 mm3 and 11005.8 mm3, respectively. Although the volume of mastoid pneumatization was smaller in the study group than in the control group, this difference was not statistically significant (P > 0.05). Conclusions: This preliminary study showed that there was no significant correlation between mastoid pneumatization volume and chronic noise-induced hearing loss. However, this correlation could be significant in further studies with a larger number of subjects.

KW - Computed tomography

KW - Hearing loss

KW - Mastoid aeration

KW - Noise-induced hearing loss

KW - Occupational hearing loss

UR - http://www.scopus.com/inward/record.url?scp=84874540309&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874540309&partnerID=8YFLogxK

M3 - Article

C2 - 23409550

AN - SCOPUS:84874540309

VL - 8

SP - 241

EP - 245

JO - B-ENT

JF - B-ENT

SN - 1781-782X

IS - 4

ER -