Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis

Konstantinos C. Siontis, Abdalla Kara Balla, Yong Mei Cha, Thomas Pilgrim, Romy Sweda, Laurent Roten, Tobias Reichlin, Paul A. Friedman, Stephan Windecker, George C.M. Siontis

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. Objective: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. Methods: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. Results: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. Conclusion: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI.

Original languageEnglish (US)
Pages (from-to)24-33
Number of pages10
JournalHeart Rhythm O2
Volume4
Issue number1
DOIs
StatePublished - Jan 2023

Keywords

  • Aortic stenosis
  • Electrophysiological study
  • Permanent pacemaker
  • Risk stratification
  • Transcatheter aortic valve implantation

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis'. Together they form a unique fingerprint.

Cite this