Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA

Andrew N. Odland, Rafael J. Sierra

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.

Original languageEnglish (US)
Pages (from-to)e1124-e1128
JournalOrthopedics
Volume37
Issue number12
DOIs
StatePublished - Dec 1 2014

Fingerprint

Arthroplasty
Hip
Hip Fractures
Metals
Femur Neck
Polyethylene
Thigh
Femur
Cicatrix
Neck
Technology
Research

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Medicine(all)

Cite this

Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. / Odland, Andrew N.; Sierra, Rafael J.

In: Orthopedics, Vol. 37, No. 12, 01.12.2014, p. e1124-e1128.

Research output: Contribution to journalArticle

Odland, Andrew N. ; Sierra, Rafael J. / Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. In: Orthopedics. 2014 ; Vol. 37, No. 12. pp. e1124-e1128.
@article{fa698cc4cd1a43cb91b9ea548f227918,
title = "Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA",
abstract = "Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.",
author = "Odland, {Andrew N.} and Sierra, {Rafael J.}",
year = "2014",
month = "12",
day = "1",
doi = "10.3928/01477447-20141124-90",
language = "English (US)",
volume = "37",
pages = "e1124--e1128",
journal = "Orthopedics",
issn = "0147-7447",
publisher = "Slack Incorporated",
number = "12",

}

TY - JOUR

T1 - Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA

AU - Odland, Andrew N.

AU - Sierra, Rafael J.

PY - 2014/12/1

Y1 - 2014/12/1

N2 - Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.

AB - Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.

UR - http://www.scopus.com/inward/record.url?scp=84914815776&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84914815776&partnerID=8YFLogxK

U2 - 10.3928/01477447-20141124-90

DO - 10.3928/01477447-20141124-90

M3 - Article

VL - 37

SP - e1124-e1128

JO - Orthopedics

JF - Orthopedics

SN - 0147-7447

IS - 12

ER -