N2 - Introduction: In response to the need for simple, rapid means of quantifying surgical capacity in low resource settings, Surgeons OverSeas (SOS) developed the personnel, infrastructure, procedures, equipment and supplies (PIPES) tool. The present investigation assessed the inter-rater reliability of the PIPES tool. Methods: As part of a government assessment of surgical services in Santa Cruz, Bolivia, the PIPES tool was translated into Spanish and applied in interviews with physicians at 31 public hospitals. An additional interview was conducted with nurses at a convenience sample of 25 of these hospitals. Physician and nurse responses were then compared to generate an estimate of reliability. For dichotomous survey items, inter-rater reliability between physicians and nurses was assessed using the Cohen's kappa statistic and percent agreement. The Pearson correlation coefficient was used to assess agreement for continuous items. Results: Cohen's kappa was 0.46 for infrastructure, 0.43 for procedures, 0.26 for equipment, and 0 for supplies sections. The median correlation coefficient was 0.91 for continuous items. Correlation was 0.79 for the PIPES index, and ranged from 0.32 to 0.98 for continuous response items. Conclusions: Reliability of the PIPES tool was moderate for the infrastructure and procedures sections, fair for the equipment section, and poor for supplies section when comparing surgeons' responses to nurses' responses - an extremely rigorous test of reliability. These results indicate that the PIPES tool is an effective measure of surgical capacity but that the equipment and supplies sections may need to be revised.
AB - Introduction: In response to the need for simple, rapid means of quantifying surgical capacity in low resource settings, Surgeons OverSeas (SOS) developed the personnel, infrastructure, procedures, equipment and supplies (PIPES) tool. The present investigation assessed the inter-rater reliability of the PIPES tool. Methods: As part of a government assessment of surgical services in Santa Cruz, Bolivia, the PIPES tool was translated into Spanish and applied in interviews with physicians at 31 public hospitals. An additional interview was conducted with nurses at a convenience sample of 25 of these hospitals. Physician and nurse responses were then compared to generate an estimate of reliability. For dichotomous survey items, inter-rater reliability between physicians and nurses was assessed using the Cohen's kappa statistic and percent agreement. The Pearson correlation coefficient was used to assess agreement for continuous items. Results: Cohen's kappa was 0.46 for infrastructure, 0.43 for procedures, 0.26 for equipment, and 0 for supplies sections. The median correlation coefficient was 0.91 for continuous items. Correlation was 0.79 for the PIPES index, and ranged from 0.32 to 0.98 for continuous response items. Conclusions: Reliability of the PIPES tool was moderate for the infrastructure and procedures sections, fair for the equipment section, and poor for supplies section when comparing surgeons' responses to nurses' responses - an extremely rigorous test of reliability. These results indicate that the PIPES tool is an effective measure of surgical capacity but that the equipment and supplies sections may need to be revised.
UR - http://www.scopus.com/inward/record.url?scp=84905708445&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84905708445&partnerID=8YFLogxK
U2 - 10.1007/s00268-014-2522-2
DO - 10.1007/s00268-014-2522-2
M3 - Article
C2 - 24696058
AN - SCOPUS:84905708445
VL - 38
SP - 2195
EP - 2199
JO - Presentations from the 9th Annual Electric Utilities Environmental Conference
JF - Presentations from the 9th Annual Electric Utilities Environmental Conference
SN - 0364-2313
IS - 9
ER -