Influence of changes in experimental parameters on size of PLGA microspheres

Jacob B. Oldham, D. Blaise Porter, Thai Sheng Tan, Helena Brisby, Bradford L. Currier, Antonios G. Mikos, Michael J Yaszemski

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

The size distribution of poly(lactic-co-glycolic acid) microspheres formulated using the double-emulsion process was manipulated with changes in vortex speeds. Changes in the molecular composition of PLGA used do not have significant effect on the size distribution of formulated microspheres.

Original languageEnglish (US)
Title of host publicationAmerican Society of Mechanical Engineers, Bioengineering Division (Publication) BED
Place of PublicationFairfield, NJ, United States
PublisherASME
Pages681-682
Number of pages2
Volume42
ISBN (Print)0791816117
StatePublished - 1999
Event1999 Bioengineering Conference - Big Sky, MT, USA
Duration: Jun 16 1999Jun 20 1999

Other

Other1999 Bioengineering Conference
CityBig Sky, MT, USA
Period6/16/996/20/99

Fingerprint

Microspheres
Emulsions
Vortex flow
Acids
Chemical analysis
Milk

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Oldham, J. B., Blaise Porter, D., Tan, T. S., Brisby, H., Currier, B. L., Mikos, A. G., & Yaszemski, M. J. (1999). Influence of changes in experimental parameters on size of PLGA microspheres. In American Society of Mechanical Engineers, Bioengineering Division (Publication) BED (Vol. 42, pp. 681-682). Fairfield, NJ, United States: ASME.

Influence of changes in experimental parameters on size of PLGA microspheres. / Oldham, Jacob B.; Blaise Porter, D.; Tan, Thai Sheng; Brisby, Helena; Currier, Bradford L.; Mikos, Antonios G.; Yaszemski, Michael J.

American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42 Fairfield, NJ, United States : ASME, 1999. p. 681-682.

Research output: Chapter in Book/Report/Conference proceedingChapter

Oldham, JB, Blaise Porter, D, Tan, TS, Brisby, H, Currier, BL, Mikos, AG & Yaszemski, MJ 1999, Influence of changes in experimental parameters on size of PLGA microspheres. in American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. vol. 42, ASME, Fairfield, NJ, United States, pp. 681-682, 1999 Bioengineering Conference, Big Sky, MT, USA, 6/16/99.
Oldham JB, Blaise Porter D, Tan TS, Brisby H, Currier BL, Mikos AG et al. Influence of changes in experimental parameters on size of PLGA microspheres. In American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42. Fairfield, NJ, United States: ASME. 1999. p. 681-682
Oldham, Jacob B. ; Blaise Porter, D. ; Tan, Thai Sheng ; Brisby, Helena ; Currier, Bradford L. ; Mikos, Antonios G. ; Yaszemski, Michael J. / Influence of changes in experimental parameters on size of PLGA microspheres. American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42 Fairfield, NJ, United States : ASME, 1999. pp. 681-682
@inbook{27a9e41fdeee494bb00f4ae89b40ac41,
title = "Influence of changes in experimental parameters on size of PLGA microspheres",
abstract = "The size distribution of poly(lactic-co-glycolic acid) microspheres formulated using the double-emulsion process was manipulated with changes in vortex speeds. Changes in the molecular composition of PLGA used do not have significant effect on the size distribution of formulated microspheres.",
author = "Oldham, {Jacob B.} and {Blaise Porter}, D. and Tan, {Thai Sheng} and Helena Brisby and Currier, {Bradford L.} and Mikos, {Antonios G.} and Yaszemski, {Michael J}",
year = "1999",
language = "English (US)",
isbn = "0791816117",
volume = "42",
pages = "681--682",
booktitle = "American Society of Mechanical Engineers, Bioengineering Division (Publication) BED",
publisher = "ASME",

}

TY - CHAP

T1 - Influence of changes in experimental parameters on size of PLGA microspheres

AU - Oldham, Jacob B.

AU - Blaise Porter, D.

AU - Tan, Thai Sheng

AU - Brisby, Helena

AU - Currier, Bradford L.

AU - Mikos, Antonios G.

AU - Yaszemski, Michael J

PY - 1999

Y1 - 1999

N2 - The size distribution of poly(lactic-co-glycolic acid) microspheres formulated using the double-emulsion process was manipulated with changes in vortex speeds. Changes in the molecular composition of PLGA used do not have significant effect on the size distribution of formulated microspheres.

AB - The size distribution of poly(lactic-co-glycolic acid) microspheres formulated using the double-emulsion process was manipulated with changes in vortex speeds. Changes in the molecular composition of PLGA used do not have significant effect on the size distribution of formulated microspheres.

UR - http://www.scopus.com/inward/record.url?scp=0342955645&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0342955645&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0342955645

SN - 0791816117

VL - 42

SP - 681

EP - 682

BT - American Society of Mechanical Engineers, Bioengineering Division (Publication) BED

PB - ASME

CY - Fairfield, NJ, United States

ER -