In vivo comparison of shape memory polymer foam-coated and bare metal coils for aneurysm occlusion in the rabbit elastase model

Scott M. Herting, Yonghong Ding, Anthony J. Boyle, Daying Dai, Landon D. Nash, Solmaz Asnafi, Daniel R. Jakaitis, Collin R. Johnson, Lance M. Graul, Chung Yeh, David F. Kallmes, Ramanathan Kadirvel, Duncan J. Maitland

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Shape memory polymer (SMP) foam-coated coils (FCCs) are new embolic coils coated with porous SMP designed to expand for increased volume filling and enhanced healing after implantation. The purpose of this study was to compare chronic aneurysm healing after treatment with SMP FCCs to bare platinum coil (BPC) controls in the rabbit elastase aneurysm model. BPCs or SMP FCCs were implanted in rabbit elastase-induced aneurysms for follow-up at 30 days (n = 10), 90 days (n = 5), and 180 days (n = 12 for BPCs; n = 14 for SMP FCCs). Aneurysm occlusion and histologic healing, including a qualitative healing score, neointima thickness, collagen deposition, and inflammation were compared between the two groups. The mean neointima thickness was significantly greater in groups treated with SMP FCCs for all three time points. Histologic healing scores and collagen deposition quantification suggested that aneurysms treated with SMP FCCs experience more complete healing of the dome by 90 days, but the differences were not statistically significant. More progressive occlusion and recanalization were observed in aneurysms treated with SMP FCCs, but neither difference was statistically significant. Additionally, the SMP foam used in the FCCs was found to degrade faster in the rabbit elastase model than expected based on previous studies in a porcine sidewall aneurysm model. This study suggests that SMP FCCs can promote neointima formation along the aneurysm neck, and may lead to more complete healing of the dome and neck. These findings indicate potential benefits of this device for aneurysm occlusion procedures.

Original languageEnglish (US)
Pages (from-to)2466-2475
Number of pages10
JournalJournal of Biomedical Materials Research - Part B Applied Biomaterials
Volume107
Issue number8
DOIs
StatePublished - Nov 1 2019

Keywords

  • aneurysm healing
  • embolization device
  • polyurethane foam
  • shape memory polymer

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'In vivo comparison of shape memory polymer foam-coated and bare metal coils for aneurysm occlusion in the rabbit elastase model'. Together they form a unique fingerprint.