Improved vibroacoustography imaging for nondestructive inspection of materials

F. G. Mitri, Mostafa Fatemi

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

We report a method to improve image quality in the nondestructive investigation and visualization of defects using vibroacoustography (VA). Vibroacoustography is an ultrasound-based imaging technique that uses the dynamic (oscillatory) radiation force of low-frequency excitation (within kilohertz range) to remotely vibrate objects and detect the ensuing acoustic emission. This technique is nondestructive and noncontact and has shown numerous capabilities to produce high-resolution images of different types of materials. However, for reflective materials, ultrasound reflects back and forth between the object and transducer, thus establishing standing waves. This phenomenon produces an artifact in the shape of false contours in the VA images. The goal of this study is to investigate the formation of the standing wave artifacts and develop a process called chirp imaging to improve defect visibility and flaw detection capability. Chirp VA experiments are performed on a flawed fiber-reinforced ceramic composite plate and on an electronic chip. To assess the efficacy of the chirp imaging process in removing the standing-wave artifact, the resulting chirp images are compared to "fixed frequency" VA images. Results show that the false contour can be significantly reduced in the image, thus remarkably improving image quality and flaw detection.

Original languageEnglish (US)
Article number114901
JournalJournal of Applied Physics
Volume98
Issue number11
DOIs
StatePublished - 2005

Fingerprint

inspection
chirp
standing waves
nondestructive tests
artifacts
chips (electronics)
defects
acoustic emission
visibility
imaging techniques
transducers
ceramics
low frequencies
composite materials
fibers
high resolution
radiation
excitation

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)
  • Physics and Astronomy(all)

Cite this

Improved vibroacoustography imaging for nondestructive inspection of materials. / Mitri, F. G.; Fatemi, Mostafa.

In: Journal of Applied Physics, Vol. 98, No. 11, 114901, 2005.

Research output: Contribution to journalArticle

@article{8ea7114101a547f68add727218b656bc,
title = "Improved vibroacoustography imaging for nondestructive inspection of materials",
abstract = "We report a method to improve image quality in the nondestructive investigation and visualization of defects using vibroacoustography (VA). Vibroacoustography is an ultrasound-based imaging technique that uses the dynamic (oscillatory) radiation force of low-frequency excitation (within kilohertz range) to remotely vibrate objects and detect the ensuing acoustic emission. This technique is nondestructive and noncontact and has shown numerous capabilities to produce high-resolution images of different types of materials. However, for reflective materials, ultrasound reflects back and forth between the object and transducer, thus establishing standing waves. This phenomenon produces an artifact in the shape of false contours in the VA images. The goal of this study is to investigate the formation of the standing wave artifacts and develop a process called chirp imaging to improve defect visibility and flaw detection capability. Chirp VA experiments are performed on a flawed fiber-reinforced ceramic composite plate and on an electronic chip. To assess the efficacy of the chirp imaging process in removing the standing-wave artifact, the resulting chirp images are compared to {"}fixed frequency{"} VA images. Results show that the false contour can be significantly reduced in the image, thus remarkably improving image quality and flaw detection.",
author = "Mitri, {F. G.} and Mostafa Fatemi",
year = "2005",
doi = "10.1063/1.2130515",
language = "English (US)",
volume = "98",
journal = "Journal of Applied Physics",
issn = "0021-8979",
publisher = "American Institute of Physics Publising LLC",
number = "11",

}

TY - JOUR

T1 - Improved vibroacoustography imaging for nondestructive inspection of materials

AU - Mitri, F. G.

AU - Fatemi, Mostafa

PY - 2005

Y1 - 2005

N2 - We report a method to improve image quality in the nondestructive investigation and visualization of defects using vibroacoustography (VA). Vibroacoustography is an ultrasound-based imaging technique that uses the dynamic (oscillatory) radiation force of low-frequency excitation (within kilohertz range) to remotely vibrate objects and detect the ensuing acoustic emission. This technique is nondestructive and noncontact and has shown numerous capabilities to produce high-resolution images of different types of materials. However, for reflective materials, ultrasound reflects back and forth between the object and transducer, thus establishing standing waves. This phenomenon produces an artifact in the shape of false contours in the VA images. The goal of this study is to investigate the formation of the standing wave artifacts and develop a process called chirp imaging to improve defect visibility and flaw detection capability. Chirp VA experiments are performed on a flawed fiber-reinforced ceramic composite plate and on an electronic chip. To assess the efficacy of the chirp imaging process in removing the standing-wave artifact, the resulting chirp images are compared to "fixed frequency" VA images. Results show that the false contour can be significantly reduced in the image, thus remarkably improving image quality and flaw detection.

AB - We report a method to improve image quality in the nondestructive investigation and visualization of defects using vibroacoustography (VA). Vibroacoustography is an ultrasound-based imaging technique that uses the dynamic (oscillatory) radiation force of low-frequency excitation (within kilohertz range) to remotely vibrate objects and detect the ensuing acoustic emission. This technique is nondestructive and noncontact and has shown numerous capabilities to produce high-resolution images of different types of materials. However, for reflective materials, ultrasound reflects back and forth between the object and transducer, thus establishing standing waves. This phenomenon produces an artifact in the shape of false contours in the VA images. The goal of this study is to investigate the formation of the standing wave artifacts and develop a process called chirp imaging to improve defect visibility and flaw detection capability. Chirp VA experiments are performed on a flawed fiber-reinforced ceramic composite plate and on an electronic chip. To assess the efficacy of the chirp imaging process in removing the standing-wave artifact, the resulting chirp images are compared to "fixed frequency" VA images. Results show that the false contour can be significantly reduced in the image, thus remarkably improving image quality and flaw detection.

UR - http://www.scopus.com/inward/record.url?scp=29144459899&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=29144459899&partnerID=8YFLogxK

U2 - 10.1063/1.2130515

DO - 10.1063/1.2130515

M3 - Article

VL - 98

JO - Journal of Applied Physics

JF - Journal of Applied Physics

SN - 0021-8979

IS - 11

M1 - 114901

ER -