T1 - Impact of gap distance between fenestration and aortic wall on target artery instability following fenestrated-branched endovascular aortic repair
AU - Chait, Jesse
AU - Tenorio, Emanuel R.
AU - Mendes, Bernardo C.
AU - Barbosa Lima, Guilherme B.
AU - Marcondes, Giulianna B.
AU - Wong, Joshua
AU - Macedo, Thanila A.
AU - De Martino, Randall R.
AU - Oderich, Gustavo S.
N1 - Funding Information:
Author conflict of interest: G.S.O. receives consulting fees from Centerline Biomedical, Cook Medical, G.E. Healthcare, and W.L. Gore and research grant support from GE Healthcare , Cook Medical , and W.L. Gore , paid to the Mayo Clinic and the University of Texas Health Science Center at Houston and has a global principal investigator agreement with Cook Medical. B.C.M. receives consulting fees from Cook Medical and W.L. Gore and research grant support from Cook Medical and W.L. Gore and is a regional aortic advisor for Medtronic (all fees paid to Mayo Clinic). J.C., E.R.T., G.B.B.L., G.B.M., J.W., T.A.M., and R.R.D. have no conflicts of interest.
Publisher Copyright:
© 2022 Society for Vascular Surgery
PY - 2022/7
Y1 - 2022/7
N2 - Objective: Target artery (TA) instability has been the most frequent indication for secondary intervention after fenestrated and branched endovascular aortic repair (FB-EVAR) of pararenal and thoracoabdominal aortic aneurysms (TAAAs). The aim of the present study was to evaluate the effect of the gap distance between the endograft reinforced fenestration and TA origin at the aortic wall (fenestration gap [FG]) on target-related outcomes after FB-EVAR. Methods: The clinical data and imaging studies of 430 patients enrolled in a prospective, nonrandomized study to evaluate FB-EVAR using manufactured stent grafts were reviewed. Of the 430 patients, 340 (79%) had had more than one vessel incorporated by fenestration. The FG was retrospectively measured on postoperative imaging studies and classified into three groups: no gap (FG, 0 mm), FG 1 to 4 mm, and FG ≥5 mm. The primary outcome was freedom from TA instability. The secondary end points included TA-related endoleak, TA secondary intervention, and TA patency. Results: A total of 1558 renal-mesenteric TAs were incorporated by 1104 reinforced fenestrations and 454 directional branches (DBs), with a mean of 3.9 ± 0.5 vessels per patient. The mean FG was 2.8 ± 4.5 mm, with an FG of 0 mm for 646 TAs, 1 to 4 mm for 209 TAs, and ≥5 mm for 249 TAs. An FG of ≥5 mm was associated with significantly lower (P <.001) freedom from TA instability, type Ic or IIIc endoleak, and secondary interventions at 5 years. Compared with DBs, fenestrations with an FG of ≥5 mm had similar primary patency and freedom from TA instability but significantly lower freedom from type Ic or IIIc endoleak (91% ± 2% vs 95% ± 1%; log rank, P =.02) and secondary interventions (87% ± 3% vs 93% ± 2%; log-rank, P =.02) at 5 years. The independent predictors of TA instability included postdissection TAAAs (hazard ratio, 2.5; 95% confidence interval, 1.2-5.4) and FG ≥5 mm (hazard ratio, 1.6; 95% confidence interval, 1.2-1.8). TAs incorporated by reinforced fenestrations had higher primary (99% ± 0.8% vs 97% ± 1.0%; P =.039) and secondary (100% vs 98% ± 1.0%; P =.012) patency rates at 5 years compared with DBs, with the lowest primary patency observed for renal DBs (80% ± 6% vs 92% ± 2%; P =.008). Conclusions: An FG of ≥5 mm was independently associated with an increased risk of TA instability, type Ic or IIIc endoleaks, and secondary interventions for patients treated by FB-EVAR using fenestrated designs. TAs incorporated by DBs had lower 5-year primary and secondary patency compared with those with reinforced fenestrations, with the lowest 5-year patency of 80% for renal branches. Compared with DBs, fenestrations with an FG of ≥5 mm carried a greater risk of type Ic or IIIc endoleak and secondary interventions. Independent predictors of TA instability included postdissection TAAAs and a greater FG. In contrast, dual antiplatelet therapy and larger TA diameters were protective.
AB - Objective: Target artery (TA) instability has been the most frequent indication for secondary intervention after fenestrated and branched endovascular aortic repair (FB-EVAR) of pararenal and thoracoabdominal aortic aneurysms (TAAAs). The aim of the present study was to evaluate the effect of the gap distance between the endograft reinforced fenestration and TA origin at the aortic wall (fenestration gap [FG]) on target-related outcomes after FB-EVAR. Methods: The clinical data and imaging studies of 430 patients enrolled in a prospective, nonrandomized study to evaluate FB-EVAR using manufactured stent grafts were reviewed. Of the 430 patients, 340 (79%) had had more than one vessel incorporated by fenestration. The FG was retrospectively measured on postoperative imaging studies and classified into three groups: no gap (FG, 0 mm), FG 1 to 4 mm, and FG ≥5 mm. The primary outcome was freedom from TA instability. The secondary end points included TA-related endoleak, TA secondary intervention, and TA patency. Results: A total of 1558 renal-mesenteric TAs were incorporated by 1104 reinforced fenestrations and 454 directional branches (DBs), with a mean of 3.9 ± 0.5 vessels per patient. The mean FG was 2.8 ± 4.5 mm, with an FG of 0 mm for 646 TAs, 1 to 4 mm for 209 TAs, and ≥5 mm for 249 TAs. An FG of ≥5 mm was associated with significantly lower (P <.001) freedom from TA instability, type Ic or IIIc endoleak, and secondary interventions at 5 years. Compared with DBs, fenestrations with an FG of ≥5 mm had similar primary patency and freedom from TA instability but significantly lower freedom from type Ic or IIIc endoleak (91% ± 2% vs 95% ± 1%; log rank, P =.02) and secondary interventions (87% ± 3% vs 93% ± 2%; log-rank, P =.02) at 5 years. The independent predictors of TA instability included postdissection TAAAs (hazard ratio, 2.5; 95% confidence interval, 1.2-5.4) and FG ≥5 mm (hazard ratio, 1.6; 95% confidence interval, 1.2-1.8). TAs incorporated by reinforced fenestrations had higher primary (99% ± 0.8% vs 97% ± 1.0%; P =.039) and secondary (100% vs 98% ± 1.0%; P =.012) patency rates at 5 years compared with DBs, with the lowest primary patency observed for renal DBs (80% ± 6% vs 92% ± 2%; P =.008). Conclusions: An FG of ≥5 mm was independently associated with an increased risk of TA instability, type Ic or IIIc endoleaks, and secondary interventions for patients treated by FB-EVAR using fenestrated designs. TAs incorporated by DBs had lower 5-year primary and secondary patency compared with those with reinforced fenestrations, with the lowest 5-year patency of 80% for renal branches. Compared with DBs, fenestrations with an FG of ≥5 mm carried a greater risk of type Ic or IIIc endoleak and secondary interventions. Independent predictors of TA instability included postdissection TAAAs and a greater FG. In contrast, dual antiplatelet therapy and larger TA diameters were protective.
KW - Aortic aneurysm
KW - Bridging stent
KW - Endoleak
KW - Fenestrated and branched endovascular aortic repair
KW - Fenestration gap
KW - Target artery instability
UR - http://www.scopus.com/inward/record.url?scp=85126539969&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85126539969&partnerID=8YFLogxK
U2 - 10.1016/j.jvs.2022.01.135
DO - 10.1016/j.jvs.2022.01.135
M3 - Article
C2 - 35181519
AN - SCOPUS:85126539969
SN - 0741-5214
VL - 76
SP - 79-87.e4
JO - Journal of Vascular Surgery
JF - Journal of Vascular Surgery
IS - 1
ER -