Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography

Thomas C. Gerber, Ronald S Kuzo, Gary E. Lane, Peter C. O'Brien, Nolan Karstaedt, Richard L. Morin, Robert E. Safford, Joseph L. Blackshear, Jerald H. Pietan

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

Purpose: To report our experience with a standardized approach to pharmacologic heart rate control and image postprocessing for computed tomographic coronary angiography (CTCA) with multislice computed tomography (MSCT). Method: Two experienced observers used transaxial tomograms and maximum-intensity projections to classify coronary segments (12 per patient, 135 consecutive patients) for degree of stenosis. One factor affecting image quality was identified for each segment that could not be assessed. Results: Nine patients (7%) were excluded for technical reasons. Of 1,512 segments from 126 patients, 1,086 (72%) were assessable (8.6 per patient). Of 300 segments from 25 patients who also had selective coronary angiography, CTCA was able to assess 211 (70%) and detected significant disease in 27 (82% sensitivity, 96% specificity, 73% positive predictive value, and 97% negative predictive value). Vessel caliber, heart rate, and Agatston score were associated with inability to assess 426 coronary segments (28%). Conclusion: Heart rate and Agatston score are important predictors of the ability to assess proximal and midcoronary segments by CTCA with MSCT.

Original languageEnglish (US)
Pages (from-to)62-69
Number of pages8
JournalJournal of Computer Assisted Tomography
Volume27
Issue number1
DOIs
StatePublished - Jan 2003

Fingerprint

Multidetector Computed Tomography
Spiral Computed Tomography
Coronary Angiography
Heart Rate
Pathologic Constriction
Sensitivity and Specificity

Keywords

  • Angiography
  • Computed tomography
  • Coronary vessels
  • Helical
  • Image quality
  • Technology assessment

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. / Gerber, Thomas C.; Kuzo, Ronald S; Lane, Gary E.; O'Brien, Peter C.; Karstaedt, Nolan; Morin, Richard L.; Safford, Robert E.; Blackshear, Joseph L.; Pietan, Jerald H.

In: Journal of Computer Assisted Tomography, Vol. 27, No. 1, 01.2003, p. 62-69.

Research output: Contribution to journalArticle

Gerber, Thomas C. ; Kuzo, Ronald S ; Lane, Gary E. ; O'Brien, Peter C. ; Karstaedt, Nolan ; Morin, Richard L. ; Safford, Robert E. ; Blackshear, Joseph L. ; Pietan, Jerald H. / Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. In: Journal of Computer Assisted Tomography. 2003 ; Vol. 27, No. 1. pp. 62-69.
@article{86a30d3579164524ba36a661234e044f,
title = "Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography",
abstract = "Purpose: To report our experience with a standardized approach to pharmacologic heart rate control and image postprocessing for computed tomographic coronary angiography (CTCA) with multislice computed tomography (MSCT). Method: Two experienced observers used transaxial tomograms and maximum-intensity projections to classify coronary segments (12 per patient, 135 consecutive patients) for degree of stenosis. One factor affecting image quality was identified for each segment that could not be assessed. Results: Nine patients (7{\%}) were excluded for technical reasons. Of 1,512 segments from 126 patients, 1,086 (72{\%}) were assessable (8.6 per patient). Of 300 segments from 25 patients who also had selective coronary angiography, CTCA was able to assess 211 (70{\%}) and detected significant disease in 27 (82{\%} sensitivity, 96{\%} specificity, 73{\%} positive predictive value, and 97{\%} negative predictive value). Vessel caliber, heart rate, and Agatston score were associated with inability to assess 426 coronary segments (28{\%}). Conclusion: Heart rate and Agatston score are important predictors of the ability to assess proximal and midcoronary segments by CTCA with MSCT.",
keywords = "Angiography, Computed tomography, Coronary vessels, Helical, Image quality, Technology assessment",
author = "Gerber, {Thomas C.} and Kuzo, {Ronald S} and Lane, {Gary E.} and O'Brien, {Peter C.} and Nolan Karstaedt and Morin, {Richard L.} and Safford, {Robert E.} and Blackshear, {Joseph L.} and Pietan, {Jerald H.}",
year = "2003",
month = "1",
doi = "10.1097/00004728-200301000-00012",
language = "English (US)",
volume = "27",
pages = "62--69",
journal = "Journal of Computer Assisted Tomography",
issn = "0363-8715",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography

AU - Gerber, Thomas C.

AU - Kuzo, Ronald S

AU - Lane, Gary E.

AU - O'Brien, Peter C.

AU - Karstaedt, Nolan

AU - Morin, Richard L.

AU - Safford, Robert E.

AU - Blackshear, Joseph L.

AU - Pietan, Jerald H.

PY - 2003/1

Y1 - 2003/1

N2 - Purpose: To report our experience with a standardized approach to pharmacologic heart rate control and image postprocessing for computed tomographic coronary angiography (CTCA) with multislice computed tomography (MSCT). Method: Two experienced observers used transaxial tomograms and maximum-intensity projections to classify coronary segments (12 per patient, 135 consecutive patients) for degree of stenosis. One factor affecting image quality was identified for each segment that could not be assessed. Results: Nine patients (7%) were excluded for technical reasons. Of 1,512 segments from 126 patients, 1,086 (72%) were assessable (8.6 per patient). Of 300 segments from 25 patients who also had selective coronary angiography, CTCA was able to assess 211 (70%) and detected significant disease in 27 (82% sensitivity, 96% specificity, 73% positive predictive value, and 97% negative predictive value). Vessel caliber, heart rate, and Agatston score were associated with inability to assess 426 coronary segments (28%). Conclusion: Heart rate and Agatston score are important predictors of the ability to assess proximal and midcoronary segments by CTCA with MSCT.

AB - Purpose: To report our experience with a standardized approach to pharmacologic heart rate control and image postprocessing for computed tomographic coronary angiography (CTCA) with multislice computed tomography (MSCT). Method: Two experienced observers used transaxial tomograms and maximum-intensity projections to classify coronary segments (12 per patient, 135 consecutive patients) for degree of stenosis. One factor affecting image quality was identified for each segment that could not be assessed. Results: Nine patients (7%) were excluded for technical reasons. Of 1,512 segments from 126 patients, 1,086 (72%) were assessable (8.6 per patient). Of 300 segments from 25 patients who also had selective coronary angiography, CTCA was able to assess 211 (70%) and detected significant disease in 27 (82% sensitivity, 96% specificity, 73% positive predictive value, and 97% negative predictive value). Vessel caliber, heart rate, and Agatston score were associated with inability to assess 426 coronary segments (28%). Conclusion: Heart rate and Agatston score are important predictors of the ability to assess proximal and midcoronary segments by CTCA with MSCT.

KW - Angiography

KW - Computed tomography

KW - Coronary vessels

KW - Helical

KW - Image quality

KW - Technology assessment

UR - http://www.scopus.com/inward/record.url?scp=0242670021&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0242670021&partnerID=8YFLogxK

U2 - 10.1097/00004728-200301000-00012

DO - 10.1097/00004728-200301000-00012

M3 - Article

C2 - 12544245

AN - SCOPUS:0242670021

VL - 27

SP - 62

EP - 69

JO - Journal of Computer Assisted Tomography

JF - Journal of Computer Assisted Tomography

SN - 0363-8715

IS - 1

ER -