TY - GEN
T1 - High volume rate 3D ultrasound imaging using fast-tilting reflectors
AU - Dong, Zhijie
AU - Li, Shuangliang
AU - Lowerison, Matthew R.
AU - Zou, Jun
AU - Song, Pengfei
N1 - Funding Information:
ACKNOWLEDGMENT This study was partially supported by the National Cancer Institute of the National Institutes of Health under Award Number R00CA214523 (to P.S.) and the National Science Foundation under Award Number NRI-1748161 (to J.Z.). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health or the National Science Foundation.
Publisher Copyright:
© 2020 IEEE.
PY - 2020/9/7
Y1 - 2020/9/7
N2 - 3-D ultrasound imaging is essential for accurate measurement of volumes, proper interpretation of anatomy, and guiding interventional procedures in the clinic. Furthermore, 3-D ultrasound imaging with a high volume rate is critical for advancing emerging techniques such as elastography, blood flow imaging, functional ultrasound (fUS) and super-resolution ultrasound localization microscopy from 2-D to 3-D. However, current 3-D ultrasound techniques are burdened by the low imaging volume rate of methods based on 1-D arrays, and the high fabrication and computational costs of 2-D arrays. Although some of the drawbacks can be mitigated by techniques such as row-column-addressing arrays, sparse arrays, and micro-beamforming, a viable solution that provides high imaging quality, low-cost, and high volume rates remains elusive. To address this challenge, this paper proposes a novel 3-D ultrasound imaging technique: Fast Acoustic Steering via Tilting Electromechanical Reflectors (FASTER). FASTER uses a water-immersible and fast-tilting microfabricated electromechanical mirror to steer ultrafast plane waves in the elevational direction to achieve large field-of-view (FOV) 3-D imaging at a high volume rate with conventional 1-D transducers. A wire phantom study using a 15 MHz transducer demonstrated that FASTER could provide spatially accurate 3-D images (48 degree or 20 mm range at 25 mm depth in the elevational direction) with a 500 Hz imaging volume rate, which has comparable imaging resolution with conventional 3-D imaging based on the mechanical translation of the 1-D transducers. A tissue-mimicking phantom study shows that FASTER provides a comparable contrast level with mechanical translation-based 3-D imaging. FASTER offers a unique solution providing high imaging volume rates, large FOVs, and low-cost 3-D imaging that can be conveniently implemented on existing clinical systems with few hardware or software modifications.
AB - 3-D ultrasound imaging is essential for accurate measurement of volumes, proper interpretation of anatomy, and guiding interventional procedures in the clinic. Furthermore, 3-D ultrasound imaging with a high volume rate is critical for advancing emerging techniques such as elastography, blood flow imaging, functional ultrasound (fUS) and super-resolution ultrasound localization microscopy from 2-D to 3-D. However, current 3-D ultrasound techniques are burdened by the low imaging volume rate of methods based on 1-D arrays, and the high fabrication and computational costs of 2-D arrays. Although some of the drawbacks can be mitigated by techniques such as row-column-addressing arrays, sparse arrays, and micro-beamforming, a viable solution that provides high imaging quality, low-cost, and high volume rates remains elusive. To address this challenge, this paper proposes a novel 3-D ultrasound imaging technique: Fast Acoustic Steering via Tilting Electromechanical Reflectors (FASTER). FASTER uses a water-immersible and fast-tilting microfabricated electromechanical mirror to steer ultrafast plane waves in the elevational direction to achieve large field-of-view (FOV) 3-D imaging at a high volume rate with conventional 1-D transducers. A wire phantom study using a 15 MHz transducer demonstrated that FASTER could provide spatially accurate 3-D images (48 degree or 20 mm range at 25 mm depth in the elevational direction) with a 500 Hz imaging volume rate, which has comparable imaging resolution with conventional 3-D imaging based on the mechanical translation of the 1-D transducers. A tissue-mimicking phantom study shows that FASTER provides a comparable contrast level with mechanical translation-based 3-D imaging. FASTER offers a unique solution providing high imaging volume rates, large FOVs, and low-cost 3-D imaging that can be conveniently implemented on existing clinical systems with few hardware or software modifications.
KW - 3-D ultrasound
KW - High volume rate
KW - Plane wave imaging
KW - Water-immersible microfabricated mirror
UR - http://www.scopus.com/inward/record.url?scp=85097868175&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85097868175&partnerID=8YFLogxK
U2 - 10.1109/IUS46767.2020.9251559
DO - 10.1109/IUS46767.2020.9251559
M3 - Conference contribution
AN - SCOPUS:85097868175
T3 - IEEE International Ultrasonics Symposium, IUS
BT - IUS 2020 - International Ultrasonics Symposium, Proceedings
PB - IEEE Computer Society
T2 - 2020 IEEE International Ultrasonics Symposium, IUS 2020
Y2 - 7 September 2020 through 11 September 2020
ER -