High-speed line scan MR angiography

D. G. Brown, Stephen J Riederer, R. C. Wright, Y. Liu, F. Farzaneh

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

We describe a system which forms MR angiographic images at high speed. Multiple axial sections are imaged sequentially using a 2DFT GRASS sequence with TR/TE 50/15 ms, 64 phase encodings per image. Reconstruction and projection of each image are performed immediately (within 220 ms) after data for that image are acquired. The projection angiogram is constructed line by line as the scan progresses, thereby totally eliminating any additional time required for reconstruction and projection.

Original languageEnglish (US)
Pages (from-to)475-482
Number of pages8
JournalMagnetic Resonance in Medicine
Volume15
Issue number3
StatePublished - 1990

Fingerprint

Angiography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Brown, D. G., Riederer, S. J., Wright, R. C., Liu, Y., & Farzaneh, F. (1990). High-speed line scan MR angiography. Magnetic Resonance in Medicine, 15(3), 475-482.

High-speed line scan MR angiography. / Brown, D. G.; Riederer, Stephen J; Wright, R. C.; Liu, Y.; Farzaneh, F.

In: Magnetic Resonance in Medicine, Vol. 15, No. 3, 1990, p. 475-482.

Research output: Contribution to journalArticle

Brown, DG, Riederer, SJ, Wright, RC, Liu, Y & Farzaneh, F 1990, 'High-speed line scan MR angiography', Magnetic Resonance in Medicine, vol. 15, no. 3, pp. 475-482.
Brown DG, Riederer SJ, Wright RC, Liu Y, Farzaneh F. High-speed line scan MR angiography. Magnetic Resonance in Medicine. 1990;15(3):475-482.
Brown, D. G. ; Riederer, Stephen J ; Wright, R. C. ; Liu, Y. ; Farzaneh, F. / High-speed line scan MR angiography. In: Magnetic Resonance in Medicine. 1990 ; Vol. 15, No. 3. pp. 475-482.
@article{0213a5adde404768a46406c87c4a1dc3,
title = "High-speed line scan MR angiography",
abstract = "We describe a system which forms MR angiographic images at high speed. Multiple axial sections are imaged sequentially using a 2DFT GRASS sequence with TR/TE 50/15 ms, 64 phase encodings per image. Reconstruction and projection of each image are performed immediately (within 220 ms) after data for that image are acquired. The projection angiogram is constructed line by line as the scan progresses, thereby totally eliminating any additional time required for reconstruction and projection.",
author = "Brown, {D. G.} and Riederer, {Stephen J} and Wright, {R. C.} and Y. Liu and F. Farzaneh",
year = "1990",
language = "English (US)",
volume = "15",
pages = "475--482",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - High-speed line scan MR angiography

AU - Brown, D. G.

AU - Riederer, Stephen J

AU - Wright, R. C.

AU - Liu, Y.

AU - Farzaneh, F.

PY - 1990

Y1 - 1990

N2 - We describe a system which forms MR angiographic images at high speed. Multiple axial sections are imaged sequentially using a 2DFT GRASS sequence with TR/TE 50/15 ms, 64 phase encodings per image. Reconstruction and projection of each image are performed immediately (within 220 ms) after data for that image are acquired. The projection angiogram is constructed line by line as the scan progresses, thereby totally eliminating any additional time required for reconstruction and projection.

AB - We describe a system which forms MR angiographic images at high speed. Multiple axial sections are imaged sequentially using a 2DFT GRASS sequence with TR/TE 50/15 ms, 64 phase encodings per image. Reconstruction and projection of each image are performed immediately (within 220 ms) after data for that image are acquired. The projection angiogram is constructed line by line as the scan progresses, thereby totally eliminating any additional time required for reconstruction and projection.

UR - http://www.scopus.com/inward/record.url?scp=0024999216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024999216&partnerID=8YFLogxK

M3 - Article

C2 - 2233226

AN - SCOPUS:0024999216

VL - 15

SP - 475

EP - 482

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -