High resolution diffusion tensor imaging of human nerves in forearm

Yuxiang Zhou, Ponnada A. Narayana, Manickam Kumaravel, Parveen Athar, Vipulkumar S. Patel, Kazim A. Sheikh

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ , were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.

Original languageEnglish (US)
Pages (from-to)1374-1383
Number of pages10
JournalJournal of Magnetic Resonance Imaging
Volume39
Issue number6
DOIs
StatePublished - Jan 1 2014
Externally publishedYes

Fingerprint

Diffusion Tensor Imaging
Forearm
Anisotropy
Radial Nerve
Peripheral Nerves
Health Insurance Portability and Accountability Act
Median Nerve
Research Ethics Committees
Informed Consent
Fats
Pathology

Keywords

  • diffusion tensor imaging
  • fractional anisotropy
  • human forearm
  • mean diffusivity
  • peripheral nerves

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Medicine(all)

Cite this

Zhou, Y., Narayana, P. A., Kumaravel, M., Athar, P., Patel, V. S., & Sheikh, K. A. (2014). High resolution diffusion tensor imaging of human nerves in forearm. Journal of Magnetic Resonance Imaging, 39(6), 1374-1383. https://doi.org/10.1002/jmri.24300

High resolution diffusion tensor imaging of human nerves in forearm. / Zhou, Yuxiang; Narayana, Ponnada A.; Kumaravel, Manickam; Athar, Parveen; Patel, Vipulkumar S.; Sheikh, Kazim A.

In: Journal of Magnetic Resonance Imaging, Vol. 39, No. 6, 01.01.2014, p. 1374-1383.

Research output: Contribution to journalArticle

Zhou, Y, Narayana, PA, Kumaravel, M, Athar, P, Patel, VS & Sheikh, KA 2014, 'High resolution diffusion tensor imaging of human nerves in forearm', Journal of Magnetic Resonance Imaging, vol. 39, no. 6, pp. 1374-1383. https://doi.org/10.1002/jmri.24300
Zhou, Yuxiang ; Narayana, Ponnada A. ; Kumaravel, Manickam ; Athar, Parveen ; Patel, Vipulkumar S. ; Sheikh, Kazim A. / High resolution diffusion tensor imaging of human nerves in forearm. In: Journal of Magnetic Resonance Imaging. 2014 ; Vol. 39, No. 6. pp. 1374-1383.
@article{160a7a5e46924475a80e99d50092e514,
title = "High resolution diffusion tensor imaging of human nerves in forearm",
abstract = "Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ⊥) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ ⊥, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.",
keywords = "diffusion tensor imaging, fractional anisotropy, human forearm, mean diffusivity, peripheral nerves",
author = "Yuxiang Zhou and Narayana, {Ponnada A.} and Manickam Kumaravel and Parveen Athar and Patel, {Vipulkumar S.} and Sheikh, {Kazim A.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1002/jmri.24300",
language = "English (US)",
volume = "39",
pages = "1374--1383",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - High resolution diffusion tensor imaging of human nerves in forearm

AU - Zhou, Yuxiang

AU - Narayana, Ponnada A.

AU - Kumaravel, Manickam

AU - Athar, Parveen

AU - Patel, Vipulkumar S.

AU - Sheikh, Kazim A.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ⊥) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ ⊥, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.

AB - Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ⊥) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ ⊥, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.

KW - diffusion tensor imaging

KW - fractional anisotropy

KW - human forearm

KW - mean diffusivity

KW - peripheral nerves

UR - http://www.scopus.com/inward/record.url?scp=84900015600&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84900015600&partnerID=8YFLogxK

U2 - 10.1002/jmri.24300

DO - 10.1002/jmri.24300

M3 - Article

C2 - 24243801

AN - SCOPUS:84900015600

VL - 39

SP - 1374

EP - 1383

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 6

ER -