TY - JOUR
T1 - Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians
AU - Fetterly, Kenneth
AU - Schueler, Beth
AU - Grams, Michael
AU - Sturchio, Glenn
AU - Bell, Malcolm
AU - Gulati, Rajiv
N1 - Publisher Copyright:
© 2017 American College of Cardiology Foundation
PY - 2017/3/13
Y1 - 2017/3/13
N2 - Objectives The first aim of this study was to assess the magnitude of radiation dose to tissues of the head and neck of physicians performing x-ray-guided interventional procedures. The second aim was to assess protection of tissues of the head offered by select wearable radiation safety devices. Background Radiation dose to tissues of the head and neck is of significant interest to practicing interventional physicians. However, methods to estimate radiation dose are not generally available, and furthermore, some of the available research relating to protection of these tissues is misleading. Methods Using a single representative geometry, scatter radiation dose to a humanoid phantom was measured using radiochromic film and normalized by the radiation dose to the left collar of the radioprotective thorax apron. Radiation protection offered by leaded glasses and by a radioabsorbent surgical cap was measured. Results In the test geometry, average radiation doses to the unprotected brain, carotid arteries, and ocular lenses were 8.4%, 17%, and 50% of the dose measured at the left collar, respectively. Two representative types of leaded glasses reduced dose to the ocular lens on the side of the physician from which the scatter originates by 27% to 62% but offered no protection to the contralateral eye. The radioabsorbent surgical cap reduced brain dose by only 3.3%. Conclusions A method by which interventional physicians can estimate dose to head and neck tissues on the basis of their personal dosimeter readings is described. Radiation protection of the ocular lenses by leaded glasses may be incomplete, and protection of the brain by a radioabsorbent surgical cap was minimal.
AB - Objectives The first aim of this study was to assess the magnitude of radiation dose to tissues of the head and neck of physicians performing x-ray-guided interventional procedures. The second aim was to assess protection of tissues of the head offered by select wearable radiation safety devices. Background Radiation dose to tissues of the head and neck is of significant interest to practicing interventional physicians. However, methods to estimate radiation dose are not generally available, and furthermore, some of the available research relating to protection of these tissues is misleading. Methods Using a single representative geometry, scatter radiation dose to a humanoid phantom was measured using radiochromic film and normalized by the radiation dose to the left collar of the radioprotective thorax apron. Radiation protection offered by leaded glasses and by a radioabsorbent surgical cap was measured. Results In the test geometry, average radiation doses to the unprotected brain, carotid arteries, and ocular lenses were 8.4%, 17%, and 50% of the dose measured at the left collar, respectively. Two representative types of leaded glasses reduced dose to the ocular lens on the side of the physician from which the scatter originates by 27% to 62% but offered no protection to the contralateral eye. The radioabsorbent surgical cap reduced brain dose by only 3.3%. Conclusions A method by which interventional physicians can estimate dose to head and neck tissues on the basis of their personal dosimeter readings is described. Radiation protection of the ocular lenses by leaded glasses may be incomplete, and protection of the brain by a radioabsorbent surgical cap was minimal.
KW - head and neck
KW - interventional fluoroscopy
KW - occupational radiation dose
KW - radiation protection
UR - http://www.scopus.com/inward/record.url?scp=85014537894&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85014537894&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2016.11.026
DO - 10.1016/j.jcin.2016.11.026
M3 - Article
C2 - 28279321
AN - SCOPUS:85014537894
SN - 1936-8798
VL - 10
SP - 520
EP - 528
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 5
ER -