Purpose: Measurement of distance stereoacuity may be useful in assessing strabismic patients, especially those with intermittent exotropia. We developed the Distance Randot Stereotest as an easily administered quantitative test for distance stereoacuity in children. By using a prototype, we reported testability, validity, and normative data. Here we report normative and validity data for the final, commercially available version of the test. Method: We administered both the Prototype and the Final Version Distance Randot Stereotest to 156 normal volunteers (2-40 years of age) and 77 strabismic patients (4-62 years of age). Test-retest data were collected for the Final Version. Results: Normative Final Version scores were similar to those obtained with the Prototype; 96% were ≤100 arcsec. Test-retests were identical in 82% and within one disparity level in 100%. Final Version scores were correlated with Prototype scores (rs = 0.64, p < 0.001). Among strabismic patients, 62.3% had abnormal stereoacuity; those with normal scores had incomitant or intermittent deviations. Nil stereoacuity was found in 27 patients, confirmed in 90.9% of retests; 17 had measurable stereoacuity, confirmed in 96.3% of retests. Patients with constant strabismus were more likely to have nil stereoacuity than patients who had intermittent strabismus (95% vs 12.2%). Conclusions: Distance Randot scores from normal subjects have low variability within each age group and high test-retest reliability. There is little overlap between Distance Randot scores from normal control and strabismic patients. The Distance Randot Stereotest is a sensitive measurement of binocular sensory status that may be useful in monitoring progression of strabismus and/or recovery after strabismus surgery.

Original languageEnglish (US)
Pages (from-to)142-146
Number of pages5
JournalJournal of AAPOS
Volume14
Issue number2
DOIs
StatePublished - Apr 2010

Fingerprint

Reproducibility of Results
Strabismus
Exotropia
Healthy Volunteers
Age Groups

ASJC Scopus subject areas

  • Ophthalmology
  • Pediatrics, Perinatology, and Child Health

Cite this

Final Version of the Distance Randot Stereotest : Normative data, reliability, and validity. / Wang, Jingyun; Hatt, Sarah R.; O'Connor, Anna R.; Drover, James R.; Adams, Russell; Birch, Eileen E.; Holmes, Jonathan M.

In: Journal of AAPOS, Vol. 14, No. 2, 04.2010, p. 142-146.

Research output: Contribution to journalArticle

Wang, Jingyun ; Hatt, Sarah R. ; O'Connor, Anna R. ; Drover, James R. ; Adams, Russell ; Birch, Eileen E. ; Holmes, Jonathan M. / Final Version of the Distance Randot Stereotest : Normative data, reliability, and validity. In: Journal of AAPOS. 2010 ; Vol. 14, No. 2. pp. 142-146.
@article{913f331e669240b0a68854de30103555,
title = "Final Version of the Distance Randot Stereotest: Normative data, reliability, and validity",
abstract = "Purpose: Measurement of distance stereoacuity may be useful in assessing strabismic patients, especially those with intermittent exotropia. We developed the Distance Randot Stereotest as an easily administered quantitative test for distance stereoacuity in children. By using a prototype, we reported testability, validity, and normative data. Here we report normative and validity data for the final, commercially available version of the test. Method: We administered both the Prototype and the Final Version Distance Randot Stereotest to 156 normal volunteers (2-40 years of age) and 77 strabismic patients (4-62 years of age). Test-retest data were collected for the Final Version. Results: Normative Final Version scores were similar to those obtained with the Prototype; 96{\%} were ≤100 arcsec. Test-retests were identical in 82{\%} and within one disparity level in 100{\%}. Final Version scores were correlated with Prototype scores (rs = 0.64, p < 0.001). Among strabismic patients, 62.3{\%} had abnormal stereoacuity; those with normal scores had incomitant or intermittent deviations. Nil stereoacuity was found in 27 patients, confirmed in 90.9{\%} of retests; 17 had measurable stereoacuity, confirmed in 96.3{\%} of retests. Patients with constant strabismus were more likely to have nil stereoacuity than patients who had intermittent strabismus (95{\%} vs 12.2{\%}). Conclusions: Distance Randot scores from normal subjects have low variability within each age group and high test-retest reliability. There is little overlap between Distance Randot scores from normal control and strabismic patients. The Distance Randot Stereotest is a sensitive measurement of binocular sensory status that may be useful in monitoring progression of strabismus and/or recovery after strabismus surgery.",
author = "Jingyun Wang and Hatt, {Sarah R.} and O'Connor, {Anna R.} and Drover, {James R.} and Russell Adams and Birch, {Eileen E.} and Holmes, {Jonathan M}",
year = "2010",
month = "4",
doi = "10.1016/j.jaapos.2009.12.159",
language = "English (US)",
volume = "14",
pages = "142--146",
journal = "Journal of AAPOS",
issn = "1091-8531",
publisher = "Mosby Inc.",
number = "2",

}

TY - JOUR

T1 - Final Version of the Distance Randot Stereotest

T2 - Normative data, reliability, and validity

AU - Wang, Jingyun

AU - Hatt, Sarah R.

AU - O'Connor, Anna R.

AU - Drover, James R.

AU - Adams, Russell

AU - Birch, Eileen E.

AU - Holmes, Jonathan M

PY - 2010/4

Y1 - 2010/4

N2 - Purpose: Measurement of distance stereoacuity may be useful in assessing strabismic patients, especially those with intermittent exotropia. We developed the Distance Randot Stereotest as an easily administered quantitative test for distance stereoacuity in children. By using a prototype, we reported testability, validity, and normative data. Here we report normative and validity data for the final, commercially available version of the test. Method: We administered both the Prototype and the Final Version Distance Randot Stereotest to 156 normal volunteers (2-40 years of age) and 77 strabismic patients (4-62 years of age). Test-retest data were collected for the Final Version. Results: Normative Final Version scores were similar to those obtained with the Prototype; 96% were ≤100 arcsec. Test-retests were identical in 82% and within one disparity level in 100%. Final Version scores were correlated with Prototype scores (rs = 0.64, p < 0.001). Among strabismic patients, 62.3% had abnormal stereoacuity; those with normal scores had incomitant or intermittent deviations. Nil stereoacuity was found in 27 patients, confirmed in 90.9% of retests; 17 had measurable stereoacuity, confirmed in 96.3% of retests. Patients with constant strabismus were more likely to have nil stereoacuity than patients who had intermittent strabismus (95% vs 12.2%). Conclusions: Distance Randot scores from normal subjects have low variability within each age group and high test-retest reliability. There is little overlap between Distance Randot scores from normal control and strabismic patients. The Distance Randot Stereotest is a sensitive measurement of binocular sensory status that may be useful in monitoring progression of strabismus and/or recovery after strabismus surgery.

AB - Purpose: Measurement of distance stereoacuity may be useful in assessing strabismic patients, especially those with intermittent exotropia. We developed the Distance Randot Stereotest as an easily administered quantitative test for distance stereoacuity in children. By using a prototype, we reported testability, validity, and normative data. Here we report normative and validity data for the final, commercially available version of the test. Method: We administered both the Prototype and the Final Version Distance Randot Stereotest to 156 normal volunteers (2-40 years of age) and 77 strabismic patients (4-62 years of age). Test-retest data were collected for the Final Version. Results: Normative Final Version scores were similar to those obtained with the Prototype; 96% were ≤100 arcsec. Test-retests were identical in 82% and within one disparity level in 100%. Final Version scores were correlated with Prototype scores (rs = 0.64, p < 0.001). Among strabismic patients, 62.3% had abnormal stereoacuity; those with normal scores had incomitant or intermittent deviations. Nil stereoacuity was found in 27 patients, confirmed in 90.9% of retests; 17 had measurable stereoacuity, confirmed in 96.3% of retests. Patients with constant strabismus were more likely to have nil stereoacuity than patients who had intermittent strabismus (95% vs 12.2%). Conclusions: Distance Randot scores from normal subjects have low variability within each age group and high test-retest reliability. There is little overlap between Distance Randot scores from normal control and strabismic patients. The Distance Randot Stereotest is a sensitive measurement of binocular sensory status that may be useful in monitoring progression of strabismus and/or recovery after strabismus surgery.

UR - http://www.scopus.com/inward/record.url?scp=77951665755&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951665755&partnerID=8YFLogxK

U2 - 10.1016/j.jaapos.2009.12.159

DO - 10.1016/j.jaapos.2009.12.159

M3 - Article

C2 - 20199880

AN - SCOPUS:77951665755

VL - 14

SP - 142

EP - 146

JO - Journal of AAPOS

JF - Journal of AAPOS

SN - 1091-8531

IS - 2

ER -