Examiner repeatability of patellar cartilage T2 values

Matthew F. Koff, Sebastien Parratte, Kimberly K. Amrami, Kenton R Kaufman

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Aim: The purpose of this study was to evaluate the intra- and interexaminer resegmentation precision of patellar cartilage T2 mapping measurements in healthy subjects. Materials and Methods: T2-weighted images of patellar cartilage for 10 subjects were acquired. Two individuals manually segmented patellar cartilage at each slice location twice, once on each of two separate days. Bulk average and zonal T2 values for the superficial, middle, and deep layers of cartilage were calculated. The root mean square (RMS) and coefficient of variation (COV) were calculated using the repeated measurements of each slice of each subject by each examiner. Results: The intraexaminer bulk T2 differences were 0.2±1.0 ms, with an RMS error of 0.7 ms and a COV of 1.9%. The differences of interexaminer bulk T2 values was 1.0±1.4 ms, with an RMS error of 1.2 ms and a COV of 3.3%. The superficial zone of cartilage had the highest zonal variability of T2 values. The average interexaminer T2 values for the superficial, middle and deep zones were 42.2±5.6, 38.1±5.3 and 31.9±4.6 ms, respectively. Conclusion: The interexaminer variability of calculated T2 values highlights the difficulty of interpreting significant differences of T2 values which are similar in magnitude. The repeatability measurements of patellar cartilage T2 values were less than reported intersession T2 repeatability.

Original languageEnglish (US)
Pages (from-to)131-136
Number of pages6
JournalMagnetic Resonance Imaging
Volume27
Issue number1
DOIs
StatePublished - Jan 2009

Fingerprint

Cartilage
Mean square error
Healthy Volunteers

Keywords

  • Cartilage
  • MRI
  • Patella
  • Reproducibility of results

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Biomedical Engineering

Cite this

Examiner repeatability of patellar cartilage T2 values. / Koff, Matthew F.; Parratte, Sebastien; Amrami, Kimberly K.; Kaufman, Kenton R.

In: Magnetic Resonance Imaging, Vol. 27, No. 1, 01.2009, p. 131-136.

Research output: Contribution to journalArticle

Koff, Matthew F. ; Parratte, Sebastien ; Amrami, Kimberly K. ; Kaufman, Kenton R. / Examiner repeatability of patellar cartilage T2 values. In: Magnetic Resonance Imaging. 2009 ; Vol. 27, No. 1. pp. 131-136.
@article{ee4fad05b0ee4114bddf0717e55f5b67,
title = "Examiner repeatability of patellar cartilage T2 values",
abstract = "Aim: The purpose of this study was to evaluate the intra- and interexaminer resegmentation precision of patellar cartilage T2 mapping measurements in healthy subjects. Materials and Methods: T2-weighted images of patellar cartilage for 10 subjects were acquired. Two individuals manually segmented patellar cartilage at each slice location twice, once on each of two separate days. Bulk average and zonal T2 values for the superficial, middle, and deep layers of cartilage were calculated. The root mean square (RMS) and coefficient of variation (COV) were calculated using the repeated measurements of each slice of each subject by each examiner. Results: The intraexaminer bulk T2 differences were 0.2±1.0 ms, with an RMS error of 0.7 ms and a COV of 1.9{\%}. The differences of interexaminer bulk T2 values was 1.0±1.4 ms, with an RMS error of 1.2 ms and a COV of 3.3{\%}. The superficial zone of cartilage had the highest zonal variability of T2 values. The average interexaminer T2 values for the superficial, middle and deep zones were 42.2±5.6, 38.1±5.3 and 31.9±4.6 ms, respectively. Conclusion: The interexaminer variability of calculated T2 values highlights the difficulty of interpreting significant differences of T2 values which are similar in magnitude. The repeatability measurements of patellar cartilage T2 values were less than reported intersession T2 repeatability.",
keywords = "Cartilage, MRI, Patella, Reproducibility of results",
author = "Koff, {Matthew F.} and Sebastien Parratte and Amrami, {Kimberly K.} and Kaufman, {Kenton R}",
year = "2009",
month = "1",
doi = "10.1016/j.mri.2008.05.004",
language = "English (US)",
volume = "27",
pages = "131--136",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Examiner repeatability of patellar cartilage T2 values

AU - Koff, Matthew F.

AU - Parratte, Sebastien

AU - Amrami, Kimberly K.

AU - Kaufman, Kenton R

PY - 2009/1

Y1 - 2009/1

N2 - Aim: The purpose of this study was to evaluate the intra- and interexaminer resegmentation precision of patellar cartilage T2 mapping measurements in healthy subjects. Materials and Methods: T2-weighted images of patellar cartilage for 10 subjects were acquired. Two individuals manually segmented patellar cartilage at each slice location twice, once on each of two separate days. Bulk average and zonal T2 values for the superficial, middle, and deep layers of cartilage were calculated. The root mean square (RMS) and coefficient of variation (COV) were calculated using the repeated measurements of each slice of each subject by each examiner. Results: The intraexaminer bulk T2 differences were 0.2±1.0 ms, with an RMS error of 0.7 ms and a COV of 1.9%. The differences of interexaminer bulk T2 values was 1.0±1.4 ms, with an RMS error of 1.2 ms and a COV of 3.3%. The superficial zone of cartilage had the highest zonal variability of T2 values. The average interexaminer T2 values for the superficial, middle and deep zones were 42.2±5.6, 38.1±5.3 and 31.9±4.6 ms, respectively. Conclusion: The interexaminer variability of calculated T2 values highlights the difficulty of interpreting significant differences of T2 values which are similar in magnitude. The repeatability measurements of patellar cartilage T2 values were less than reported intersession T2 repeatability.

AB - Aim: The purpose of this study was to evaluate the intra- and interexaminer resegmentation precision of patellar cartilage T2 mapping measurements in healthy subjects. Materials and Methods: T2-weighted images of patellar cartilage for 10 subjects were acquired. Two individuals manually segmented patellar cartilage at each slice location twice, once on each of two separate days. Bulk average and zonal T2 values for the superficial, middle, and deep layers of cartilage were calculated. The root mean square (RMS) and coefficient of variation (COV) were calculated using the repeated measurements of each slice of each subject by each examiner. Results: The intraexaminer bulk T2 differences were 0.2±1.0 ms, with an RMS error of 0.7 ms and a COV of 1.9%. The differences of interexaminer bulk T2 values was 1.0±1.4 ms, with an RMS error of 1.2 ms and a COV of 3.3%. The superficial zone of cartilage had the highest zonal variability of T2 values. The average interexaminer T2 values for the superficial, middle and deep zones were 42.2±5.6, 38.1±5.3 and 31.9±4.6 ms, respectively. Conclusion: The interexaminer variability of calculated T2 values highlights the difficulty of interpreting significant differences of T2 values which are similar in magnitude. The repeatability measurements of patellar cartilage T2 values were less than reported intersession T2 repeatability.

KW - Cartilage

KW - MRI

KW - Patella

KW - Reproducibility of results

UR - http://www.scopus.com/inward/record.url?scp=57049108250&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57049108250&partnerID=8YFLogxK

U2 - 10.1016/j.mri.2008.05.004

DO - 10.1016/j.mri.2008.05.004

M3 - Article

C2 - 18801631

AN - SCOPUS:57049108250

VL - 27

SP - 131

EP - 136

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 1

ER -