TY - JOUR
T1 - Estimated limits of IMRT dose escalation using varied planning target volume margins
AU - Goulet, Christopher C.
AU - Herman, Michael G.
AU - Hillman, David W.
AU - Davis, Brian J.
PY - 2008/7/21
Y1 - 2008/7/21
N2 - To estimate the limits of dose escalation for prostate cancer as a function of planning target volume (PTV) margins, the maximum achievable dose (MAD) was determined through iterative plan optimizations from data sets of 18 patients until the dose constraints for rectum, bladder and PTV could no longer be met. PTV margins of 10, 5 and 3 mm yielded a mean MAD of 83.0 Gy (range, 73.8-108.0 Gy), 113.1 Gy (range, 90.0-151.2 Gy) and 135.9 Gy (range, 102.6-189.0 Gy), respectively. All comparisons of MAD among margin groups were statistically significant (P < 0.001). Comparison of prostate volumes of 30-50 mL (n = 8) with volumes of 51-70 mL (n = 7) and 71-105 mL (n = 3) showed an inverse relationship with MAD. Decreases in PTV margin significantly decreased the PTV overlap of the rectum (P < 0.001 for all margin comparisons). With decreases in the PTV margin and maintenance of identical dose constraints, doses well above those currently prescribed for treatment of localized prostate cancer appear feasible. However, the dose escalation suggested by these findings is a theoretical estimate, and additional dose constraints will likely be necessary to limit toxicity to normal tissue.
AB - To estimate the limits of dose escalation for prostate cancer as a function of planning target volume (PTV) margins, the maximum achievable dose (MAD) was determined through iterative plan optimizations from data sets of 18 patients until the dose constraints for rectum, bladder and PTV could no longer be met. PTV margins of 10, 5 and 3 mm yielded a mean MAD of 83.0 Gy (range, 73.8-108.0 Gy), 113.1 Gy (range, 90.0-151.2 Gy) and 135.9 Gy (range, 102.6-189.0 Gy), respectively. All comparisons of MAD among margin groups were statistically significant (P < 0.001). Comparison of prostate volumes of 30-50 mL (n = 8) with volumes of 51-70 mL (n = 7) and 71-105 mL (n = 3) showed an inverse relationship with MAD. Decreases in PTV margin significantly decreased the PTV overlap of the rectum (P < 0.001 for all margin comparisons). With decreases in the PTV margin and maintenance of identical dose constraints, doses well above those currently prescribed for treatment of localized prostate cancer appear feasible. However, the dose escalation suggested by these findings is a theoretical estimate, and additional dose constraints will likely be necessary to limit toxicity to normal tissue.
UR - http://www.scopus.com/inward/record.url?scp=47649105060&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=47649105060&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/53/14/005
DO - 10.1088/0031-9155/53/14/005
M3 - Article
C2 - 18574311
AN - SCOPUS:47649105060
SN - 0031-9155
VL - 53
SP - 3777
EP - 3788
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 14
ER -