T1 - Electronic noise in CT detectors
T2 - Impact on image noise and artifacts
AU - Duan, Xinhui
AU - Wang, Jia
AU - Leng, Shuai
AU - Schmidt, Bernhard
AU - Allmendinger, Thomas
AU - Grant, Katharine
AU - Flohr, Thomas
AU - McCollough, Cynthia H.
PY - 2013/10/1
Y1 - 2013/10/1
N2 - OBJECTIVE. The OBJECTIVE of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. MATERIALS AND METHODS. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. RESULTS. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. CONCLUSION. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.
AB - OBJECTIVE. The OBJECTIVE of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. MATERIALS AND METHODS. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. RESULTS. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. CONCLUSION. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.
KW - Artifacts
KW - Electronics
KW - Noise
KW - Radiation dosage
KW - X-ray CT
UR - http://www.scopus.com/inward/record.url?scp=84878907151&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84878907151&partnerID=8YFLogxK
U2 - 10.2214/AJR.12.10234
DO - 10.2214/AJR.12.10234
M3 - Article
C2 - 24059402
AN - SCOPUS:84878907151
SN - 0361-803X
VL - 201
SP - W626-W632
JO - The American journal of roentgenology and radium therapy
JF - The American journal of roentgenology and radium therapy
IS - 4
ER -