Efficient correction for CT image artifacts caused by objects extending outside the scan field of view

B. Ohnesorge, T. Flohr, K. Schwarz, Jay Heiken, K. T. Bae

Research output: Contribution to journalArticle

169 Citations (Scopus)

Abstract

The purpose of this paper is to develop a method of eliminating CT image artifacts generated by objects extending outside the scan field of view, such as obese or inadequately positioned patients. CT projection data are measured only within the scan field of view and thus are abruptly discontinuous at the projection boundaries if the scanned object extends outside the scan field of view. This data discontinuity causes an artifact that consists of a bright peripheral band that obscures objects near the boundary of the scan field of view. An adaptive mathematical extrapolation scheme with low computational expense was applied to reduce the data discontinuity prior to convolution in a filtered backprojection reconstruction. Despite extended projection length, the convolution length was not increased and thus the reconstruction time was not affected. Raw projection data from ten patients whose bodies extended beyond the scan field of view were reconstructed using a conventional method and our extended reconstruction method. Limitations of the algorithm are investigated and extensions for further improvement are discussed. The images reconstructed by conventional filtered backprojection demonstrated peripheral bright-band artifacts near the boundary of the scan field of view. Images reconstructed with our technique were free of such artifacts and clearly showed the anatomy at the periphery of the scan field of view with correct attenuation values. We conclude that bright-band artifacts generated by obese patients whose bodies extend beyond the scan field of view were eliminated with our reconstruction method, which reduces boundary data discontinuity. The algorithm can be generalized to objects with inhomogeneous peripheral density and to true 'Region of Interest Reconstruction' from truncated projections.

Original languageEnglish (US)
Pages (from-to)39-46
Number of pages8
JournalMedical Physics
Volume27
Issue number1
DOIs
StatePublished - Jan 1 2000
Externally publishedYes

Fingerprint

Artifacts
Anatomy

Keywords

  • CT
  • Peripheral artifact
  • Region-of-interest reconstruction
  • Truncated projections

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. / Ohnesorge, B.; Flohr, T.; Schwarz, K.; Heiken, Jay; Bae, K. T.

In: Medical Physics, Vol. 27, No. 1, 01.01.2000, p. 39-46.

Research output: Contribution to journalArticle

Ohnesorge, B. ; Flohr, T. ; Schwarz, K. ; Heiken, Jay ; Bae, K. T. / Efficient correction for CT image artifacts caused by objects extending outside the scan field of view. In: Medical Physics. 2000 ; Vol. 27, No. 1. pp. 39-46.
@article{4e5cf95751e149d3a408ef3a46067b34,
title = "Efficient correction for CT image artifacts caused by objects extending outside the scan field of view",
abstract = "The purpose of this paper is to develop a method of eliminating CT image artifacts generated by objects extending outside the scan field of view, such as obese or inadequately positioned patients. CT projection data are measured only within the scan field of view and thus are abruptly discontinuous at the projection boundaries if the scanned object extends outside the scan field of view. This data discontinuity causes an artifact that consists of a bright peripheral band that obscures objects near the boundary of the scan field of view. An adaptive mathematical extrapolation scheme with low computational expense was applied to reduce the data discontinuity prior to convolution in a filtered backprojection reconstruction. Despite extended projection length, the convolution length was not increased and thus the reconstruction time was not affected. Raw projection data from ten patients whose bodies extended beyond the scan field of view were reconstructed using a conventional method and our extended reconstruction method. Limitations of the algorithm are investigated and extensions for further improvement are discussed. The images reconstructed by conventional filtered backprojection demonstrated peripheral bright-band artifacts near the boundary of the scan field of view. Images reconstructed with our technique were free of such artifacts and clearly showed the anatomy at the periphery of the scan field of view with correct attenuation values. We conclude that bright-band artifacts generated by obese patients whose bodies extend beyond the scan field of view were eliminated with our reconstruction method, which reduces boundary data discontinuity. The algorithm can be generalized to objects with inhomogeneous peripheral density and to true 'Region of Interest Reconstruction' from truncated projections.",
keywords = "CT, Peripheral artifact, Region-of-interest reconstruction, Truncated projections",
author = "B. Ohnesorge and T. Flohr and K. Schwarz and Jay Heiken and Bae, {K. T.}",
year = "2000",
month = "1",
day = "1",
doi = "10.1118/1.598855",
language = "English (US)",
volume = "27",
pages = "39--46",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "1",

}

TY - JOUR

T1 - Efficient correction for CT image artifacts caused by objects extending outside the scan field of view

AU - Ohnesorge, B.

AU - Flohr, T.

AU - Schwarz, K.

AU - Heiken, Jay

AU - Bae, K. T.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - The purpose of this paper is to develop a method of eliminating CT image artifacts generated by objects extending outside the scan field of view, such as obese or inadequately positioned patients. CT projection data are measured only within the scan field of view and thus are abruptly discontinuous at the projection boundaries if the scanned object extends outside the scan field of view. This data discontinuity causes an artifact that consists of a bright peripheral band that obscures objects near the boundary of the scan field of view. An adaptive mathematical extrapolation scheme with low computational expense was applied to reduce the data discontinuity prior to convolution in a filtered backprojection reconstruction. Despite extended projection length, the convolution length was not increased and thus the reconstruction time was not affected. Raw projection data from ten patients whose bodies extended beyond the scan field of view were reconstructed using a conventional method and our extended reconstruction method. Limitations of the algorithm are investigated and extensions for further improvement are discussed. The images reconstructed by conventional filtered backprojection demonstrated peripheral bright-band artifacts near the boundary of the scan field of view. Images reconstructed with our technique were free of such artifacts and clearly showed the anatomy at the periphery of the scan field of view with correct attenuation values. We conclude that bright-band artifacts generated by obese patients whose bodies extend beyond the scan field of view were eliminated with our reconstruction method, which reduces boundary data discontinuity. The algorithm can be generalized to objects with inhomogeneous peripheral density and to true 'Region of Interest Reconstruction' from truncated projections.

AB - The purpose of this paper is to develop a method of eliminating CT image artifacts generated by objects extending outside the scan field of view, such as obese or inadequately positioned patients. CT projection data are measured only within the scan field of view and thus are abruptly discontinuous at the projection boundaries if the scanned object extends outside the scan field of view. This data discontinuity causes an artifact that consists of a bright peripheral band that obscures objects near the boundary of the scan field of view. An adaptive mathematical extrapolation scheme with low computational expense was applied to reduce the data discontinuity prior to convolution in a filtered backprojection reconstruction. Despite extended projection length, the convolution length was not increased and thus the reconstruction time was not affected. Raw projection data from ten patients whose bodies extended beyond the scan field of view were reconstructed using a conventional method and our extended reconstruction method. Limitations of the algorithm are investigated and extensions for further improvement are discussed. The images reconstructed by conventional filtered backprojection demonstrated peripheral bright-band artifacts near the boundary of the scan field of view. Images reconstructed with our technique were free of such artifacts and clearly showed the anatomy at the periphery of the scan field of view with correct attenuation values. We conclude that bright-band artifacts generated by obese patients whose bodies extend beyond the scan field of view were eliminated with our reconstruction method, which reduces boundary data discontinuity. The algorithm can be generalized to objects with inhomogeneous peripheral density and to true 'Region of Interest Reconstruction' from truncated projections.

KW - CT

KW - Peripheral artifact

KW - Region-of-interest reconstruction

KW - Truncated projections

UR - http://www.scopus.com/inward/record.url?scp=0033954645&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033954645&partnerID=8YFLogxK

U2 - 10.1118/1.598855

DO - 10.1118/1.598855

M3 - Article

C2 - 10659736

AN - SCOPUS:0033954645

VL - 27

SP - 39

EP - 46

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 1

ER -