T1 - Effects of foot orthoses on the work of friction of the posterior tibial tendon
AU - Hirano, Takaaki
AU - McCullough, Matthew B.A.
AU - Kitaoka, Harold B.
AU - Ikoma, Kazuya
AU - Kaufman, Kenton R.
PY - 2009/11/1
Y1 - 2009/11/1
N2 - Background: Posterior tibial tendon dysfunction is a significant contributor to flatfeet. Non-operative treatments, like in-shoe orthoses, have varying degrees of success. This study examined changes to the work of friction of the posterior tibial tendon under three conditions: intact, simulated flatfoot, and flatfoot with an orthosis. It was hypothesized that work of friction of the posterior tibial tendon would significantly increase in the flatfoot, yet return to normal with an orthosis. Changes to bone orientation were also expected. Methods: Six lower limb cadavers were mounted in a foot simulator, that applied axial and a posterior tibial tendon load. Posterior tibial tendon excursion, gliding resistance, and foot kinematics were monitored, and work of friction calculated. Each specimen moved through a range of motion in the coronal, transverse, and sagittal planes. Findings: Mean work of friction during motion in the coronal plane were 0.17 N cm (SD 0.07 N cm), 0.25 N cm (SD 0.09 N cm), and 0.23 N cm (SD 0.09 N cm) for the intact, flatfoot, and orthosis conditions, respectively. Motion in the transverse plane yielded average WoF of 0.36 N cm (SD 0.28 N cm), 0.64 N cm (SD 0.25 N cm), and 0.57 N cm (SD 0.38 N cm) in the same three conditions, respectively. The average tibio-calcaneal and tibio-metatarsal valgus angles significantly increased in the flatfoot condition (5.8° and 9°, respectively). However, the orthosis did slightly correct this angle. Interpretation: The prefabricated orthosis did not consistently restore normal work of friction, though it did correct the flatfoot visually. This implies that patients with flatfeet may be predisposed to developing posterior tibial tendon dysfunction due to abnormal gliding resistance, though bone orientations are restored.
AB - Background: Posterior tibial tendon dysfunction is a significant contributor to flatfeet. Non-operative treatments, like in-shoe orthoses, have varying degrees of success. This study examined changes to the work of friction of the posterior tibial tendon under three conditions: intact, simulated flatfoot, and flatfoot with an orthosis. It was hypothesized that work of friction of the posterior tibial tendon would significantly increase in the flatfoot, yet return to normal with an orthosis. Changes to bone orientation were also expected. Methods: Six lower limb cadavers were mounted in a foot simulator, that applied axial and a posterior tibial tendon load. Posterior tibial tendon excursion, gliding resistance, and foot kinematics were monitored, and work of friction calculated. Each specimen moved through a range of motion in the coronal, transverse, and sagittal planes. Findings: Mean work of friction during motion in the coronal plane were 0.17 N cm (SD 0.07 N cm), 0.25 N cm (SD 0.09 N cm), and 0.23 N cm (SD 0.09 N cm) for the intact, flatfoot, and orthosis conditions, respectively. Motion in the transverse plane yielded average WoF of 0.36 N cm (SD 0.28 N cm), 0.64 N cm (SD 0.25 N cm), and 0.57 N cm (SD 0.38 N cm) in the same three conditions, respectively. The average tibio-calcaneal and tibio-metatarsal valgus angles significantly increased in the flatfoot condition (5.8° and 9°, respectively). However, the orthosis did slightly correct this angle. Interpretation: The prefabricated orthosis did not consistently restore normal work of friction, though it did correct the flatfoot visually. This implies that patients with flatfeet may be predisposed to developing posterior tibial tendon dysfunction due to abnormal gliding resistance, though bone orientations are restored.
KW - Ankle
KW - Biomechanics
KW - Foot
KW - Orthotics
KW - Work of friction
UR - http://www.scopus.com/inward/record.url?scp=70249084814&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70249084814&partnerID=8YFLogxK
U2 - 10.1016/j.clinbiomech.2009.07.009
DO - 10.1016/j.clinbiomech.2009.07.009
M3 - Article
C2 - 19700230
AN - SCOPUS:70249084814
SN - 0268-0033
VL - 24
SP - 776
EP - 780
JO - Clinical Biomechanics
JF - Clinical Biomechanics
IS - 9
ER -