Effect of image display on the quality of multiplanar reconstruction of computed tomography data

Elliot K. Fishman, Derek R. Ney, Akira Kawashima, William W. Scott, Douglas D. Robertson

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Rationale and Objectives: The objective of this study is to determine whether the use of edge-enhancement post-processing filters was useful in the computed tomographic (CT) multiplanar evaluation of skeletal trauma. Methods: The group consisted of a series of 10 cases of skeletal trauma (3 cases of acetabular fractures, 3 cases of tibial plateau fractures, and 4 cases of ankle fractures). AH patients had a CT scan using a scan protocol of 4-mm collimation and 3-mm interscan interval. All transaxial images were reconstructed with both a standard algorithm and with an edge-enhancement filter. The images from each group were then reconstructed into coronal and sagittal planes. Three individuals independently reviewed each case and compared image pairs to determine whether images using an edge-enhancement filter were of better or worse quality than standard images. Results. The reviewers found the images with edge-enhancement to be equal to or superior to images reconstructed with a standard algorithm, regardless of the image plane chosen. This bias was especially true in cases of hip and ankle trauma. Conclusions: When CT supplemented by multiplanar imaging is used in patients with skeletal trauma, image data reconstruction should be done with an edge-enhancement filter to optimize image detail.

Original languageEnglish (US)
Pages (from-to)146-149
Number of pages4
JournalInvestigative Radiology
Volume28
Issue number2
DOIs
StatePublished - Jan 1 1993
Externally publishedYes

Fingerprint

Tomography
Wounds and Injuries
Ankle Fractures
Tibial Fractures
Computer-Assisted Image Processing
Ankle
Hip

Keywords

  • High-resolution computed tomographic scanning
  • Image processing
  • Multiplanar reconstruction
  • Reconstruction algorithm

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Effect of image display on the quality of multiplanar reconstruction of computed tomography data. / Fishman, Elliot K.; Ney, Derek R.; Kawashima, Akira; Scott, William W.; Robertson, Douglas D.

In: Investigative Radiology, Vol. 28, No. 2, 01.01.1993, p. 146-149.

Research output: Contribution to journalArticle

Fishman, Elliot K. ; Ney, Derek R. ; Kawashima, Akira ; Scott, William W. ; Robertson, Douglas D. / Effect of image display on the quality of multiplanar reconstruction of computed tomography data. In: Investigative Radiology. 1993 ; Vol. 28, No. 2. pp. 146-149.
@article{157575167d554631a4c3a5a35ecfbca8,
title = "Effect of image display on the quality of multiplanar reconstruction of computed tomography data",
abstract = "Rationale and Objectives: The objective of this study is to determine whether the use of edge-enhancement post-processing filters was useful in the computed tomographic (CT) multiplanar evaluation of skeletal trauma. Methods: The group consisted of a series of 10 cases of skeletal trauma (3 cases of acetabular fractures, 3 cases of tibial plateau fractures, and 4 cases of ankle fractures). AH patients had a CT scan using a scan protocol of 4-mm collimation and 3-mm interscan interval. All transaxial images were reconstructed with both a standard algorithm and with an edge-enhancement filter. The images from each group were then reconstructed into coronal and sagittal planes. Three individuals independently reviewed each case and compared image pairs to determine whether images using an edge-enhancement filter were of better or worse quality than standard images. Results. The reviewers found the images with edge-enhancement to be equal to or superior to images reconstructed with a standard algorithm, regardless of the image plane chosen. This bias was especially true in cases of hip and ankle trauma. Conclusions: When CT supplemented by multiplanar imaging is used in patients with skeletal trauma, image data reconstruction should be done with an edge-enhancement filter to optimize image detail.",
keywords = "High-resolution computed tomographic scanning, Image processing, Multiplanar reconstruction, Reconstruction algorithm",
author = "Fishman, {Elliot K.} and Ney, {Derek R.} and Akira Kawashima and Scott, {William W.} and Robertson, {Douglas D.}",
year = "1993",
month = "1",
day = "1",
doi = "10.1097/00004424-199302000-00012",
language = "English (US)",
volume = "28",
pages = "146--149",
journal = "Investigative Radiology",
issn = "0020-9996",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Effect of image display on the quality of multiplanar reconstruction of computed tomography data

AU - Fishman, Elliot K.

AU - Ney, Derek R.

AU - Kawashima, Akira

AU - Scott, William W.

AU - Robertson, Douglas D.

PY - 1993/1/1

Y1 - 1993/1/1

N2 - Rationale and Objectives: The objective of this study is to determine whether the use of edge-enhancement post-processing filters was useful in the computed tomographic (CT) multiplanar evaluation of skeletal trauma. Methods: The group consisted of a series of 10 cases of skeletal trauma (3 cases of acetabular fractures, 3 cases of tibial plateau fractures, and 4 cases of ankle fractures). AH patients had a CT scan using a scan protocol of 4-mm collimation and 3-mm interscan interval. All transaxial images were reconstructed with both a standard algorithm and with an edge-enhancement filter. The images from each group were then reconstructed into coronal and sagittal planes. Three individuals independently reviewed each case and compared image pairs to determine whether images using an edge-enhancement filter were of better or worse quality than standard images. Results. The reviewers found the images with edge-enhancement to be equal to or superior to images reconstructed with a standard algorithm, regardless of the image plane chosen. This bias was especially true in cases of hip and ankle trauma. Conclusions: When CT supplemented by multiplanar imaging is used in patients with skeletal trauma, image data reconstruction should be done with an edge-enhancement filter to optimize image detail.

AB - Rationale and Objectives: The objective of this study is to determine whether the use of edge-enhancement post-processing filters was useful in the computed tomographic (CT) multiplanar evaluation of skeletal trauma. Methods: The group consisted of a series of 10 cases of skeletal trauma (3 cases of acetabular fractures, 3 cases of tibial plateau fractures, and 4 cases of ankle fractures). AH patients had a CT scan using a scan protocol of 4-mm collimation and 3-mm interscan interval. All transaxial images were reconstructed with both a standard algorithm and with an edge-enhancement filter. The images from each group were then reconstructed into coronal and sagittal planes. Three individuals independently reviewed each case and compared image pairs to determine whether images using an edge-enhancement filter were of better or worse quality than standard images. Results. The reviewers found the images with edge-enhancement to be equal to or superior to images reconstructed with a standard algorithm, regardless of the image plane chosen. This bias was especially true in cases of hip and ankle trauma. Conclusions: When CT supplemented by multiplanar imaging is used in patients with skeletal trauma, image data reconstruction should be done with an edge-enhancement filter to optimize image detail.

KW - High-resolution computed tomographic scanning

KW - Image processing

KW - Multiplanar reconstruction

KW - Reconstruction algorithm

UR - http://www.scopus.com/inward/record.url?scp=0027397681&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027397681&partnerID=8YFLogxK

U2 - 10.1097/00004424-199302000-00012

DO - 10.1097/00004424-199302000-00012

M3 - Article

VL - 28

SP - 146

EP - 149

JO - Investigative Radiology

JF - Investigative Radiology

SN - 0020-9996

IS - 2

ER -