Dose to radiosensitive organs during routine chest CT: Effects of tube current modulation

Erin Angel, Nazanin Yaghmai, Cecilia Matilda Jude, John J. DeMarco, Christopher H. Cagnon, Jonathan G. Goldin, Cynthia H McCollough, Andrew N. Primak, Dianna D. Cody, Donna M. Stevens, Michael F. McNitt-Gray

Research output: Contribution to journalArticle

62 Citations (Scopus)

Abstract

OBJECTIVE. The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS. Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS. The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION. The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.

Original languageEnglish (US)
Pages (from-to)1340-1345
Number of pages6
JournalAmerican Journal of Roentgenology
Volume193
Issue number5
DOIs
StatePublished - Nov 2009

Fingerprint

Thorax
Lung
Breast
Organ Size
Radiation

Keywords

  • CT
  • Monte Carlo simulation
  • Radiation dose
  • Tube current modulation
  • Voxelized patient model

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Angel, E., Yaghmai, N., Jude, C. M., DeMarco, J. J., Cagnon, C. H., Goldin, J. G., ... McNitt-Gray, M. F. (2009). Dose to radiosensitive organs during routine chest CT: Effects of tube current modulation. American Journal of Roentgenology, 193(5), 1340-1345. https://doi.org/10.2214/AJR.09.2886

Dose to radiosensitive organs during routine chest CT : Effects of tube current modulation. / Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; McCollough, Cynthia H; Primak, Andrew N.; Cody, Dianna D.; Stevens, Donna M.; McNitt-Gray, Michael F.

In: American Journal of Roentgenology, Vol. 193, No. 5, 11.2009, p. 1340-1345.

Research output: Contribution to journalArticle

Angel, E, Yaghmai, N, Jude, CM, DeMarco, JJ, Cagnon, CH, Goldin, JG, McCollough, CH, Primak, AN, Cody, DD, Stevens, DM & McNitt-Gray, MF 2009, 'Dose to radiosensitive organs during routine chest CT: Effects of tube current modulation', American Journal of Roentgenology, vol. 193, no. 5, pp. 1340-1345. https://doi.org/10.2214/AJR.09.2886
Angel, Erin ; Yaghmai, Nazanin ; Jude, Cecilia Matilda ; DeMarco, John J. ; Cagnon, Christopher H. ; Goldin, Jonathan G. ; McCollough, Cynthia H ; Primak, Andrew N. ; Cody, Dianna D. ; Stevens, Donna M. ; McNitt-Gray, Michael F. / Dose to radiosensitive organs during routine chest CT : Effects of tube current modulation. In: American Journal of Roentgenology. 2009 ; Vol. 193, No. 5. pp. 1340-1345.
@article{3d1c28e0658844098dc146a4608c192a,
title = "Dose to radiosensitive organs during routine chest CT: Effects of tube current modulation",
abstract = "OBJECTIVE. The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS. Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS. The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16{\%}. Reductions in organ dose (up to 56{\%} for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33{\%}. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION. The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.",
keywords = "CT, Monte Carlo simulation, Radiation dose, Tube current modulation, Voxelized patient model",
author = "Erin Angel and Nazanin Yaghmai and Jude, {Cecilia Matilda} and DeMarco, {John J.} and Cagnon, {Christopher H.} and Goldin, {Jonathan G.} and McCollough, {Cynthia H} and Primak, {Andrew N.} and Cody, {Dianna D.} and Stevens, {Donna M.} and McNitt-Gray, {Michael F.}",
year = "2009",
month = "11",
doi = "10.2214/AJR.09.2886",
language = "English (US)",
volume = "193",
pages = "1340--1345",
journal = "American Journal of Roentgenology",
issn = "0361-803X",
publisher = "American Roentgen Ray Society",
number = "5",

}

TY - JOUR

T1 - Dose to radiosensitive organs during routine chest CT

T2 - Effects of tube current modulation

AU - Angel, Erin

AU - Yaghmai, Nazanin

AU - Jude, Cecilia Matilda

AU - DeMarco, John J.

AU - Cagnon, Christopher H.

AU - Goldin, Jonathan G.

AU - McCollough, Cynthia H

AU - Primak, Andrew N.

AU - Cody, Dianna D.

AU - Stevens, Donna M.

AU - McNitt-Gray, Michael F.

PY - 2009/11

Y1 - 2009/11

N2 - OBJECTIVE. The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS. Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS. The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION. The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.

AB - OBJECTIVE. The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS. Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS. The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION. The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.

KW - CT

KW - Monte Carlo simulation

KW - Radiation dose

KW - Tube current modulation

KW - Voxelized patient model

UR - http://www.scopus.com/inward/record.url?scp=70449513167&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449513167&partnerID=8YFLogxK

U2 - 10.2214/AJR.09.2886

DO - 10.2214/AJR.09.2886

M3 - Article

C2 - 19843751

AN - SCOPUS:70449513167

VL - 193

SP - 1340

EP - 1345

JO - American Journal of Roentgenology

JF - American Journal of Roentgenology

SN - 0361-803X

IS - 5

ER -