Distal radial fractures

Volar, dorsal, fragment-specific, and spanning plates

L. V. Floccari, D. G. Dennison

Research output: Contribution to journalArticle

Abstract

The rate of operative treatment of distal radial fractures has risen significantly over the past 2 decades. Technological advancements in plating options have contributed to this trend. Volar locking plates have rapidly gained popularity as the technique of choice, but recent literature suggests that volar locking plates only provide short-term benefit with faster recovery of function but equivalent clinical results at 1yr when compared with external fixation and pins. Volar locking plates do result in improved radiographic results, so longer-term studies are needed for further analysis. Dorsal plating provides improved exposure of the articular surface, and newer generation low-profile dorsal plates have lower tendon-related complication rates. Dorsal spanning plates often are used in polytrauma patients with severe intraarticular fractures to restore length and alignment while facilitating immediate unrestricted use of the hand. Fragment-specific fixation uses customizable implants to assist with anatomic reduction of multifragmented, intraarticular fractures of the distal radius. Here, we provide an overview of literature published from 2013-2014 concerning volar, dorsal, fragment-specific, and spanning plate fixation, complications, and technological updates for the surgical treatment of distal radial fractures.

Original languageEnglish (US)
Pages (from-to)433-438
Number of pages6
JournalCurrent Orthopaedic Practice
Volume25
Issue number5
StatePublished - 2014

Fingerprint

Intra-Articular Fractures
Multiple Trauma
Recovery of Function
Tendons
Hand
Joints
Therapeutics

Keywords

  • Fracture
  • Operative
  • Plate
  • Radius
  • Wrist

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Distal radial fractures : Volar, dorsal, fragment-specific, and spanning plates. / Floccari, L. V.; Dennison, D. G.

In: Current Orthopaedic Practice, Vol. 25, No. 5, 2014, p. 433-438.

Research output: Contribution to journalArticle

Floccari, L. V. ; Dennison, D. G. / Distal radial fractures : Volar, dorsal, fragment-specific, and spanning plates. In: Current Orthopaedic Practice. 2014 ; Vol. 25, No. 5. pp. 433-438.
@article{9decb561c17b431a9c01eed2202bfd25,
title = "Distal radial fractures: Volar, dorsal, fragment-specific, and spanning plates",
abstract = "The rate of operative treatment of distal radial fractures has risen significantly over the past 2 decades. Technological advancements in plating options have contributed to this trend. Volar locking plates have rapidly gained popularity as the technique of choice, but recent literature suggests that volar locking plates only provide short-term benefit with faster recovery of function but equivalent clinical results at 1yr when compared with external fixation and pins. Volar locking plates do result in improved radiographic results, so longer-term studies are needed for further analysis. Dorsal plating provides improved exposure of the articular surface, and newer generation low-profile dorsal plates have lower tendon-related complication rates. Dorsal spanning plates often are used in polytrauma patients with severe intraarticular fractures to restore length and alignment while facilitating immediate unrestricted use of the hand. Fragment-specific fixation uses customizable implants to assist with anatomic reduction of multifragmented, intraarticular fractures of the distal radius. Here, we provide an overview of literature published from 2013-2014 concerning volar, dorsal, fragment-specific, and spanning plate fixation, complications, and technological updates for the surgical treatment of distal radial fractures.",
keywords = "Fracture, Operative, Plate, Radius, Wrist",
author = "Floccari, {L. V.} and Dennison, {D. G.}",
year = "2014",
language = "English (US)",
volume = "25",
pages = "433--438",
journal = "Current Orthopaedic Practice",
issn = "1940-7041",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Distal radial fractures

T2 - Volar, dorsal, fragment-specific, and spanning plates

AU - Floccari, L. V.

AU - Dennison, D. G.

PY - 2014

Y1 - 2014

N2 - The rate of operative treatment of distal radial fractures has risen significantly over the past 2 decades. Technological advancements in plating options have contributed to this trend. Volar locking plates have rapidly gained popularity as the technique of choice, but recent literature suggests that volar locking plates only provide short-term benefit with faster recovery of function but equivalent clinical results at 1yr when compared with external fixation and pins. Volar locking plates do result in improved radiographic results, so longer-term studies are needed for further analysis. Dorsal plating provides improved exposure of the articular surface, and newer generation low-profile dorsal plates have lower tendon-related complication rates. Dorsal spanning plates often are used in polytrauma patients with severe intraarticular fractures to restore length and alignment while facilitating immediate unrestricted use of the hand. Fragment-specific fixation uses customizable implants to assist with anatomic reduction of multifragmented, intraarticular fractures of the distal radius. Here, we provide an overview of literature published from 2013-2014 concerning volar, dorsal, fragment-specific, and spanning plate fixation, complications, and technological updates for the surgical treatment of distal radial fractures.

AB - The rate of operative treatment of distal radial fractures has risen significantly over the past 2 decades. Technological advancements in plating options have contributed to this trend. Volar locking plates have rapidly gained popularity as the technique of choice, but recent literature suggests that volar locking plates only provide short-term benefit with faster recovery of function but equivalent clinical results at 1yr when compared with external fixation and pins. Volar locking plates do result in improved radiographic results, so longer-term studies are needed for further analysis. Dorsal plating provides improved exposure of the articular surface, and newer generation low-profile dorsal plates have lower tendon-related complication rates. Dorsal spanning plates often are used in polytrauma patients with severe intraarticular fractures to restore length and alignment while facilitating immediate unrestricted use of the hand. Fragment-specific fixation uses customizable implants to assist with anatomic reduction of multifragmented, intraarticular fractures of the distal radius. Here, we provide an overview of literature published from 2013-2014 concerning volar, dorsal, fragment-specific, and spanning plate fixation, complications, and technological updates for the surgical treatment of distal radial fractures.

KW - Fracture

KW - Operative

KW - Plate

KW - Radius

KW - Wrist

UR - http://www.scopus.com/inward/record.url?scp=84927702750&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927702750&partnerID=8YFLogxK

M3 - Article

VL - 25

SP - 433

EP - 438