Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy

Ashley Smith, S. Kim, C. Serago, K. Hintenlang, R. Pooley, D. Hintenlang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

We have developed a non-invasive temperature based respiration sensor to track the breathing cycle during respiratory gating that is not subject to the limitations of an external marker. The sensor tracks the breathing cycle by measuring temperature difference between inspiratory and expiratory air. Because it doesn’t require movement of the abdomen, it can be used with forced shallow breathing (FSB) or thermoplastic body mask immobilization. The sensor is compatible for use in computed tomography (CT), magnetic resonance (MR), and linear accelerator environments. The respiration signal was tested with five volunteers using FSB and compared to simultaneously recorded signal from an external marker. Temperature readings were also tested in a CT, MR, and linear accelerator environment. The sensor’s effect on image quality was evaluated for CT and MR. The temperature sensor successfully recorded the breathing cycle for all volunteers, while the external marker had one failure. Fluctuation in temperature sensor signal was similar to background in both a CT and MR environment. There was greater signal fluctuation when the sensor was placed in a high energy linear accelerator field and given a high dose. The fluctuation was acceptable when the sensor was outside the radiation field. It is recommended that the sensor be placed outside the treatment field during treatment. Image quality was not affected by the temperature sensor for CT or MR. We have shown that the temperature based respiration sensor can successfully track breathing cycles even when external markers fail. Performance is maintained in MR and ionizing radiation environments; however, it is recommended that it not be used in the direct path of a high energy beam. We have verified that respiratory signals can be obtained without deterioration of CT or MR images. It is anticipated that this device would be highly suitable for respiratory gating in radiation therapy.

Original languageEnglish (US)
Title of host publicationIFMBE Proceedings
PublisherSpringer Verlag
Pages603-606
Number of pages4
Volume51
ISBN (Print)9783319193878
DOIs
StatePublished - 2015
EventWorld Congress on Medical Physics and Biomedical Engineering, 2015 - Toronto, Canada
Duration: Jun 7 2015Jun 12 2015

Other

OtherWorld Congress on Medical Physics and Biomedical Engineering, 2015
CountryCanada
CityToronto
Period6/7/156/12/15

Fingerprint

Radiotherapy
Magnetic resonance
Tomography
Optical fibers
Sensors
Linear accelerators
Temperature sensors
Temperature
Image quality
Ionizing radiation
Thermoplastics
Deterioration
Masks
Radiation
Air

Keywords

  • Fiber optic sensor
  • Radiation therapy
  • Respiration sensor
  • Respiratory gating

ASJC Scopus subject areas

  • Biomedical Engineering
  • Bioengineering

Cite this

Smith, A., Kim, S., Serago, C., Hintenlang, K., Pooley, R., & Hintenlang, D. (2015). Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy. In IFMBE Proceedings (Vol. 51, pp. 603-606). Springer Verlag. https://doi.org/10.1007/978-3-319-19387-8_148

Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy. / Smith, Ashley; Kim, S.; Serago, C.; Hintenlang, K.; Pooley, R.; Hintenlang, D.

IFMBE Proceedings. Vol. 51 Springer Verlag, 2015. p. 603-606.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Smith, A, Kim, S, Serago, C, Hintenlang, K, Pooley, R & Hintenlang, D 2015, Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy. in IFMBE Proceedings. vol. 51, Springer Verlag, pp. 603-606, World Congress on Medical Physics and Biomedical Engineering, 2015, Toronto, Canada, 6/7/15. https://doi.org/10.1007/978-3-319-19387-8_148
Smith A, Kim S, Serago C, Hintenlang K, Pooley R, Hintenlang D. Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy. In IFMBE Proceedings. Vol. 51. Springer Verlag. 2015. p. 603-606 https://doi.org/10.1007/978-3-319-19387-8_148
Smith, Ashley ; Kim, S. ; Serago, C. ; Hintenlang, K. ; Pooley, R. ; Hintenlang, D. / Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy. IFMBE Proceedings. Vol. 51 Springer Verlag, 2015. pp. 603-606
@inproceedings{0cce9717805344e29c9c94c264a60396,
title = "Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy",
abstract = "We have developed a non-invasive temperature based respiration sensor to track the breathing cycle during respiratory gating that is not subject to the limitations of an external marker. The sensor tracks the breathing cycle by measuring temperature difference between inspiratory and expiratory air. Because it doesn’t require movement of the abdomen, it can be used with forced shallow breathing (FSB) or thermoplastic body mask immobilization. The sensor is compatible for use in computed tomography (CT), magnetic resonance (MR), and linear accelerator environments. The respiration signal was tested with five volunteers using FSB and compared to simultaneously recorded signal from an external marker. Temperature readings were also tested in a CT, MR, and linear accelerator environment. The sensor’s effect on image quality was evaluated for CT and MR. The temperature sensor successfully recorded the breathing cycle for all volunteers, while the external marker had one failure. Fluctuation in temperature sensor signal was similar to background in both a CT and MR environment. There was greater signal fluctuation when the sensor was placed in a high energy linear accelerator field and given a high dose. The fluctuation was acceptable when the sensor was outside the radiation field. It is recommended that the sensor be placed outside the treatment field during treatment. Image quality was not affected by the temperature sensor for CT or MR. We have shown that the temperature based respiration sensor can successfully track breathing cycles even when external markers fail. Performance is maintained in MR and ionizing radiation environments; however, it is recommended that it not be used in the direct path of a high energy beam. We have verified that respiratory signals can be obtained without deterioration of CT or MR images. It is anticipated that this device would be highly suitable for respiratory gating in radiation therapy.",
keywords = "Fiber optic sensor, Radiation therapy, Respiration sensor, Respiratory gating",
author = "Ashley Smith and S. Kim and C. Serago and K. Hintenlang and R. Pooley and D. Hintenlang",
year = "2015",
doi = "10.1007/978-3-319-19387-8_148",
language = "English (US)",
isbn = "9783319193878",
volume = "51",
pages = "603--606",
booktitle = "IFMBE Proceedings",
publisher = "Springer Verlag",

}

TY - GEN

T1 - Development of an MR and CT compatible non-invasive temperature based optical fiber respiration sensor for use in radiotherapy

AU - Smith, Ashley

AU - Kim, S.

AU - Serago, C.

AU - Hintenlang, K.

AU - Pooley, R.

AU - Hintenlang, D.

PY - 2015

Y1 - 2015

N2 - We have developed a non-invasive temperature based respiration sensor to track the breathing cycle during respiratory gating that is not subject to the limitations of an external marker. The sensor tracks the breathing cycle by measuring temperature difference between inspiratory and expiratory air. Because it doesn’t require movement of the abdomen, it can be used with forced shallow breathing (FSB) or thermoplastic body mask immobilization. The sensor is compatible for use in computed tomography (CT), magnetic resonance (MR), and linear accelerator environments. The respiration signal was tested with five volunteers using FSB and compared to simultaneously recorded signal from an external marker. Temperature readings were also tested in a CT, MR, and linear accelerator environment. The sensor’s effect on image quality was evaluated for CT and MR. The temperature sensor successfully recorded the breathing cycle for all volunteers, while the external marker had one failure. Fluctuation in temperature sensor signal was similar to background in both a CT and MR environment. There was greater signal fluctuation when the sensor was placed in a high energy linear accelerator field and given a high dose. The fluctuation was acceptable when the sensor was outside the radiation field. It is recommended that the sensor be placed outside the treatment field during treatment. Image quality was not affected by the temperature sensor for CT or MR. We have shown that the temperature based respiration sensor can successfully track breathing cycles even when external markers fail. Performance is maintained in MR and ionizing radiation environments; however, it is recommended that it not be used in the direct path of a high energy beam. We have verified that respiratory signals can be obtained without deterioration of CT or MR images. It is anticipated that this device would be highly suitable for respiratory gating in radiation therapy.

AB - We have developed a non-invasive temperature based respiration sensor to track the breathing cycle during respiratory gating that is not subject to the limitations of an external marker. The sensor tracks the breathing cycle by measuring temperature difference between inspiratory and expiratory air. Because it doesn’t require movement of the abdomen, it can be used with forced shallow breathing (FSB) or thermoplastic body mask immobilization. The sensor is compatible for use in computed tomography (CT), magnetic resonance (MR), and linear accelerator environments. The respiration signal was tested with five volunteers using FSB and compared to simultaneously recorded signal from an external marker. Temperature readings were also tested in a CT, MR, and linear accelerator environment. The sensor’s effect on image quality was evaluated for CT and MR. The temperature sensor successfully recorded the breathing cycle for all volunteers, while the external marker had one failure. Fluctuation in temperature sensor signal was similar to background in both a CT and MR environment. There was greater signal fluctuation when the sensor was placed in a high energy linear accelerator field and given a high dose. The fluctuation was acceptable when the sensor was outside the radiation field. It is recommended that the sensor be placed outside the treatment field during treatment. Image quality was not affected by the temperature sensor for CT or MR. We have shown that the temperature based respiration sensor can successfully track breathing cycles even when external markers fail. Performance is maintained in MR and ionizing radiation environments; however, it is recommended that it not be used in the direct path of a high energy beam. We have verified that respiratory signals can be obtained without deterioration of CT or MR images. It is anticipated that this device would be highly suitable for respiratory gating in radiation therapy.

KW - Fiber optic sensor

KW - Radiation therapy

KW - Respiration sensor

KW - Respiratory gating

UR - http://www.scopus.com/inward/record.url?scp=84944315346&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84944315346&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-19387-8_148

DO - 10.1007/978-3-319-19387-8_148

M3 - Conference contribution

SN - 9783319193878

VL - 51

SP - 603

EP - 606

BT - IFMBE Proceedings

PB - Springer Verlag

ER -